TROUBLESHOOTING GUIDE - OPERATION

FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM

 

 

 

 

PROBLEM

 

WHAT TO DO

 

 

 

 

 

Check power source,

 

 

 

– Plug a lamp into outlet used for powerhead. If lamp works, power source is OK.

 

 

– If not, check fuse or circuit breaker.

 

Opener does NOT run

• If power is OK,

 

 

– Check connections at powerhead terminals and at wall console.

from wall console.

 

 

– Limits must be set with door arm connected to door.

 

 

 

Check if wall console Sure-Lock™ is ON. Turn Sure-Lock™ OFF & check operation.

 

• Check for reversed, broken, or cut wires. Staples can cut insulation and short wires.

 

 

Repair or replace.

 

 

Make sure carriage is engaged to chain or belt bullet. See pages 11 and 19. Refer to

Opener runs, but door

 

Installation poster or download poster from WWW.GENIECOMPANY.COM.

 

– Ensure carriage is in engaged position. See page 19.

does NOT move.

 

Check to make sure chain/belt is not broken or OFF its pulley.

 

 

• Check FORCE ADJUSTMENT. See page 23.

 

Opener works from

Check all remotes.

 

wall console, but NOT

Replace remote battery with good one. See page 21.

from remote.

Program remote to powerhead. See pages 9 or 10.

Relocate remote inside car and or point remote at garage door. Remote has less than • Replace battery. See page 21.

25 feet operating

• Reposition door opener antenna.

range or no operation.

Remote LED does not come ON with button push - replace battery. See page 21.

 

• Eliminate possible competing signals (satellite radio, FiOS® TV).

Door starts down,

• If a NEW installation, check Door Arm position. Refer to Installation poster or download

 

poster from WWW.GENIECOMPANY.COM.

then STOPS and goes

Check if Limits are properly set. See pages 6-7.

back up.

Check if Safe-T-Beam® Red LED is flashing. See page 18.

OR

• Check Safe-T-Beam® system for beam obstruction or misalignment of lenses. See page 18.

Check garage door for binding.

If an operational problem exists, and opener will not close. The opener can be forced to

Safe-T-Beam® System close as follows; Press and hold the wall console button until door is completely closed.

malfunction.• Check for interference from adjacent Safe-T-Beam® units.

Contact The Genie Company at 1-800-35-GENIE.

Door starts down,

Check Safe-T-Beam® wire connections at powerhead. See page 18.

then STOPS before it

Check Limits are properly set. See pages 6-7.

is closed.

• Check CONTACT REVERSE. See page 18.

OR

Check garage door for binding.

Door will only open.

Check closing "FORCE" adjustment. See page 23.

Door starts up, but

Check Limits are properly set. See pages 6-7.

Be sure door, opener, and springs are in good repair, properly lubricated and balanced.

STOPS before it is

Check opening "FORCE" adjustment. See page 23.

completely open.

WARNING: If you suspect a problem with the garage door hardware or springs,

 

 

contact The Genie Company at 1-800-35-GENIE.

 

Check Limits are properly set. See pages 6-7.

Door will only run

Check Sure-Lock™. Sure-Lock™ should be OFF for normal operation. See page 20.

Check door balance, condition, and door spring.

closed.

Check opening "FORCE" adjustment. See page 23.

 

WARNING: If you suspect a problem with the garage door hardware or springs,

 

 

contact The Genie Company at 1-800-35-GENIE.

Door opener starts for

Button stuck on wall console or remote.

Was a remote lost or stolen? Erase all remotes from powerhead memory and program

no reason.

 

new remotes. See page 15.

 

 

24

©2010 The Genie Company

12/2010

Image 24
Contents Operation and Maintenance Manual Potential Hazard PreventionOpener Features Safety FeaturesTable of Contents Important Installation Instructions Infrared Protection FunctionProgramming Limits & Force Close Door Travel LimitOpen Door Travel Limit See long Blue LED flashingDoor Limits are set Both LEDs flash Blue Go OFFAdjustment TestBring remotes to powerhead location See long Purple LED flashingIntelliCode 1 remotes See round Blue LED come onGenie IntelliCode 1 wireless keypad Genie IntelliCode 1 remoteSee one See long Purple LED flashing + see both LEDs Flash PurpleReference Powerhead & Rail Assembled View Power Head Tête DE Puissance Cabeza DE LA EnergíaInstallation Typique SUR UNE Porte Sectionelle Typical ONE Piece Door Installation Overview of Powerhead Controls On powerheadProgramming Buttons location Overview Remotes and Options HoldIntellicode Features Maintenance & Troubleshooting Transmitter Compliance StatementRoutine Monthly Maintenance AdjustmentSafe-T-Beam System Check Door balance Contact reverse Door Balance Spring TensionReset OPEN/CLOSE Travel Limit DoorChange Light Bulbs Motion DETECTOR* OverviewWire routing Wall Console OverviewOpen and closes door from inside garage Closed Unlock allows controls to work normallyChain or Belt Tension Adjustment Remote Battery ReplacementBelt ChainAdjustment Guide Speed Settings Change Speed SettingPowerhead LEDs Round LED Long LED Adjustment Guide Force Settings Change Force SettingTroubleshooting Guide Operation Powerhead LED Possible Problem Solution Reference Circuit Wiring Diagram Opening Cover May Cause Electric ShockLimited Warranty