CONTACT REVERSE TEST

 

 

 

 

 

The Force and Limit settings on the previous page MUST be COMPLETED before Contact

 

Reverse testing.

 

1. Test.

 

 

• Open garage door using wall console.

©2010

 

– Place a 2" x 4" board (laid flat) under center of garage door opening.

 

• Close garage door using wall console.

The

 

• When door contacts board, the door must stop (within 2 seconds) and reverse direction

 

returning to open position.

Genie

2. Adjustment.

 

Company

 

• If the door:

 

– Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set

 

 

down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

 

 

– Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to

 

 

the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

 

 

• Test again. Repeat as necessary until door reverses upon contacting board.

PRESS and RELEASE

2

3

12/2010

DOOR OPENS

WARNING

A moving door can cause serious injury or death.

1.Keep people clear of opening while door is moving.

2.Do NOT allow children to play with opener, including wall console, remote, or wireless keypad.

3.During programming, door opener could begin to run, so stay away from moving door and its parts.

On Wall Console

1PRESS and RELEASE

4

Once the Contact Reverse Testing is complete continue with Programming Remotes on the next page.

Image 8
Contents Operation and Maintenance Manual Potential Hazard PreventionOpener Features Safety FeaturesTable of Contents Important Installation Instructions Infrared Protection FunctionProgramming Limits & Force Close Door Travel LimitOpen Door Travel Limit See long Blue LED flashingDoor Limits are set Both LEDs flash Blue Go OFFAdjustment TestBring remotes to powerhead location See long Purple LED flashingIntelliCode 1 remotes See round Blue LED come onGenie IntelliCode 1 wireless keypad Genie IntelliCode 1 remoteSee one See long Purple LED flashing + see both LEDs Flash PurpleReference Powerhead & Rail Assembled View Power Head Tête DE Puissance Cabeza DE LA EnergíaInstallation Typique SUR UNE Porte Sectionelle Typical ONE Piece Door Installation Programming Buttons location Overview of Powerhead ControlsOn powerhead Overview Remotes and Options HoldIntellicode Features Maintenance & Troubleshooting Transmitter Compliance StatementRoutine Monthly Maintenance AdjustmentSafe-T-Beam System Check Door balance Contact reverse Door Balance Spring TensionReset OPEN/CLOSE Travel Limit DoorChange Light Bulbs Motion DETECTOR* OverviewWire routing Wall Console OverviewOpen and closes door from inside garage Closed Unlock allows controls to work normallyChain or Belt Tension Adjustment Remote Battery ReplacementBelt ChainPowerhead LEDs Round LED Long LED Adjustment Guide Speed SettingsChange Speed Setting Adjustment Guide Force Settings Change Force SettingTroubleshooting Guide Operation Powerhead LED Possible Problem Solution Reference Circuit Wiring Diagram Opening Cover May Cause Electric ShockLimited Warranty