Genie 4024H Routine Monthly Maintenance, Safe-T-Beam System Check Door balance Contact reverse

Page 18

WARNING

• Garage door hardware (springs, cables, brackets,

pulleys, etc.) are under extreme pressure and

tension.

DO NOT attempt to repair or adjust door

springs or any hardware, and DO NOT OPERATE

garage door automatically or manually if door

is improperly balanced or springs are broken.

WARNING

Use wall console supplied with opener. Other approved wall consoles may be available. Unapproved or incompatible wall consoles can cause the opener to operate unexpectedly.

Safe-T-Beam® (STB) SYSTEM CHECK

• STB Red and Green LEDs ON steady, system OK

CONTACT A TRAINED DOOR SYSTEM

TECHNICIAN.

ROUTINE MONTHLY MAINTENANCE

Basic monthly maintenance tasks.

Safe-T-Beam® System Check

Door balance

Contact reverse

Instructions for these tasks and others are found on

STB Red LED flashes

Check for obstruction

Check alignment

Verify wire routing from STBs to STB connection in powerhead

Check for signal interference from another Safe-T-Beam® unit

FROM STBs

STB

FROM WALL

CONSOLE

NOT NOT

USED USED

BWC IWC

the following pages.

DOOR BALANCE (SPRING TENSION)

No STB Red or Green LED displayed

Check wiring and wire connections

With the door closed, pull release handle DOWN and let go to release door carriage assembly from drive system.

Raise door manually approximately 3’- 4’ and release.

Door should remain stationary or move very slightly.

If door moves quickly, CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.

Close the door.

Verify RED block in carriage is in the up position. (refer to page 19)

Operate door using remote or wall console.

Door will re-attach itself to carriage assembly.

3’ - 4’

Sectional Door

FIG. 6-1 Door balance

3’ - 4’

One-Piece Door

CONTACT REVERSE TEST (Monthly test)

The Force and Limit settings MUST be COMPLETED before testing. (See pages 6-7)

1.Test.

Open garage door using wall console.

Place a 2" x 4" board (laid flat) under center of garage door opening (Fig. 6-2).

Close garage door using wall console.

When door contacts board, the door must stop (within 2 seconds) and reverse direction returning to open position.

2.Adjustment.

If the door:

Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

Stops after contacting the 2 x 4 board and does not reverse, it may need an adjustment to the down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit.

Test again. Repeat as necessary until door reverses upon contacting board.

FIG. 6-2 2 x 4 under center of door opening

18

©2010 The Genie Company

12/2010

Image 18
Contents Operation and Maintenance Manual Potential Hazard PreventionOpener Features Safety FeaturesTable of Contents Important Installation Instructions Infrared Protection FunctionProgramming Limits & Force Close Door Travel LimitDoor Limits are set Open Door Travel LimitSee long Blue LED flashing Both LEDs flash Blue Go OFFAdjustment TestIntelliCode 1 remotes Bring remotes to powerhead locationSee long Purple LED flashing See round Blue LED come onSee one Genie IntelliCode 1 wireless keypadGenie IntelliCode 1 remote See long Purple LED flashing + see both LEDs Flash PurpleReference Powerhead & Rail Assembled View Power Head Tête DE Puissance Cabeza DE LA EnergíaInstallation Typique SUR UNE Porte Sectionelle Typical ONE Piece Door Installation Overview of Powerhead Controls On powerheadProgramming Buttons location Overview Remotes and Options HoldIntellicode Features Maintenance & Troubleshooting Transmitter Compliance StatementSafe-T-Beam System Check Door balance Contact reverse Routine Monthly MaintenanceAdjustment Door Balance Spring TensionChange Light Bulbs Reset OPEN/CLOSE Travel LimitDoor Motion DETECTOR* OverviewOpen and closes door from inside garage Wire routingWall Console Overview Closed Unlock allows controls to work normallyBelt Chain or Belt Tension AdjustmentRemote Battery Replacement ChainAdjustment Guide Speed Settings Change Speed SettingPowerhead LEDs Round LED Long LED Adjustment Guide Force Settings Change Force SettingTroubleshooting Guide Operation Powerhead LED Possible Problem Solution Reference Circuit Wiring Diagram Opening Cover May Cause Electric ShockLimited Warranty