Genie 3511035556 manual Check your ceiling where the power, Head of your new unit will be mounted

Page 2

PRE-INSTALLATION CHECK LIST FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM

Things to consider if you are planning to “do-it-yourself.”

Whether you are replacing an existing garage door operator or installing an operator in your garage for the first time, there are some pre-installation issues which need to be addressed. They are as follows:

2The Genie Company recommends that you read and fully understand all information and instructions contained herein before choosing a do-it-yourself installation. Any questions should be directed to the Genie Company or an authorized Genie Dealer.

(The issue numbers below refer to the circled numbers in the illustrations on page 3.)

1

Check your ceiling where the power

head of your new unit will be mounted.

Plan how you will be mounting the power head. It is possible that ceiling joists may not be in the exact position needed with respect to the garage door operator. It may be necessary to add an additional bracket and fasteners (not included with your new door operator kit).

2 Check the wall directly above the garage door. The door operator’s header bracket

must be securely fastened to this wall. Ensure that the structure will provide a strong mounting location.

3 Check to see if the mounting location for the Safe-T-Beam®System (STB) is

clear from obstruction and has a wood surface available for attaching the STB brack-

ets. The brackets may be attached to concrete if necessary but extra tools and special fasteners (not supplied) will be required.

NOTE: 1-1/2" STB bracket adapters are available through your local Genie Dealer.

4 Is your garage door made of light-weight steel, aluminum, fiberglass

or glass panels? Additional support bracing must be added to these type doors. If this is the case, please contact the door distributor or manufacturer so that they can furnish you with a “bracing kit.”

WARNING

DO NOT USE AN EXTENSION CORD! Extension cords can cause dangerous overheating conditions.

DO NOT USE A PORTABLE GENERATOR! This product is designed to operate on standard house current. Do not use alternate power supplies.

5 You need a 110-120 Volt power supply available. The outlet should be no more than

3 feet from the power head once it is mounted. (The cord is 4 ft. in length.) SEE WARNING BELOW.

6 To avoid damage to your door and/or operator, make sure you disable any door

locks prior to installing your operator.

7

Ensure that your door is properly balanced

and moving freely. SEE WARNING BELOW.

8 (NOT SHOWN) If your garage does not have a separate entry door, you should consider

an emergency release kit (GER-2) for installation on your garage door. See page C at the center of this manual.

WARNING

If your door sticks, binds, or is out of balance, have it adjusted by a professional. Door springs, cables, pulleys, brackets and associated hardware are under extreme tension and can cause serious injury or death.

HomeLink® is a universal transceiver (a combined

transmitter and receiver), that provides a convenient way to replace up to three hand-held radio-frequency (RF) transmitters used to activate devices such as gate operators, garage door openers, entry door locks, security systems and even home lighting. Additional HomeLink® information can be found at: www.homelink.com or by calling 1.800.355.3515.

Image 2
Contents Series IS, ISL, IC, H HomeLink is a universal transceiver a combined Check your ceiling where the powerHead of your new unit will be mounted Typical 1-PIECE Door Installation Table of Contents Power Head Parts List Operational FeaturesParts List Piece Rail Hardware Exploded ViewSystem is Fasteners Shown full size. See Parts List for description Parts IdentificationInstall the entrapment Warning label Safety InformationPRE-INSTALLATION Warning Sect 1-MAIN Assembly Install couplerMain Assembly Attach middle rail BSlide collar Make sure rail assembly is resting straight and level Install carriage stopInstall carriage Attach end rail CAttach emergency release knob, cord Attach limit switchesSwitch TagSect 2-INSTALLATION Determining header bracket locationFinal header bracket mounting location InstallationFinding highest point of travel Mounting preparation Mount header bracketAttaching rail to header bracket Support device, such as a ladderMounting power head Suspended Ceiling . It must beMounting door bracket Possible. -12A & BFor 1-piece doors Adjust emergency release knob heightAttach door arms 23 For sectional doors Mounting brackets Sect 3-SAFE-T-BEAM InstallationWiring Mounting STB source and sensorSAFE-T-BEAM Installation Check the followingMount wall control. Fig Sect 4-WALL Control InstallationAttach wires to terminals. -2, Fig Mount entrapment warning label. FigSect 5 -LIGHT & Lens Installation With Grounded Plug Sect 6-CONNECTING PowerConnect Power with Plug Adjust closing force Sect 7-SETTINGS Force & LimitsAdjust opening force Install/replace battery Fig Sect 8-BATTERY & Visor ClipSettings Contact Reverse Attach visor clip FigProgramming Remote Controls Safety Instructions Monthly Maintenance Sect 10-MAINTENANCE & TroubleshootingTroubleshooting Maintenance CHECK-OFFMaintenance & Troubleshooting Use only with included Series II wall controlSect 11-WIRING Diagram Electrical ShockVisit Our Website at Visitar Website nuestro en Garage Door Operator Accessories Order Form Genie Company

3511035556 specifications

The Genie 3511035556 is a sophisticated piece of technology designed to meet the demands of modern lifting and material handling tasks. This model is particularly notable for its exceptional efficiency, safety features, and versatility, making it suitable for various industrial applications.

One of the standout features of the Genie 3511035556 is its advanced hydraulic system, which allows for smooth and precise operation. This hydraulic system not only enhances lifting capacity but also ensures that the platform can rise quickly and steadily, reducing downtime and increasing productivity on job sites. The lift has a maximum working height that is ideal for accessing elevated areas, while its compact design allows for maneuverability in tight spaces.

In terms of safety, the Genie 3511035556 is equipped with several innovative technologies. The model includes a robust safety cage with guardrails that provide secure access for operators. Additionally, the anti-rollback and overload protection systems are integrated to prevent accidents and ensure that the lifting operations are performed safely. These features help to mitigate risks, providing peace of mind for operators and supervisors alike.

The Genie 3511035556 also boasts a user-friendly control system. Operators benefit from an intuitive interface that can easily control the lift’s various functions, allowing for quick adjustments and operations. This ease of use is complemented by a range of smart technology options, including diagnostics that notify operators of potential maintenance needs before they become an issue. This proactive approach to maintenance not only enhances safety but also extends the lifecycle of the equipment.

Durability is another prominent characteristic of the Genie 3511035556. Its construction utilizes high-quality materials designed to withstand the rigors of daily use in challenging environments. This robust build ensures that the lift can maintain optimal performance even under heavy loads, making it a reliable choice for construction sites, warehouses, and maintenance applications.

In summary, the Genie 3511035556 stands out for its powerful hydraulic system, comprehensive safety features, user-friendly interface, and durable construction. This model is engineered for superior performance and reliability, catering to the needs of professionals seeking efficiency and safety in their lifting operations. As industries continue to evolve, lifts like the Genie 3511035556 play a crucial role in enhancing workflow and ensuring safe handling of materials at various heights.