Allstar Products Group 3000, J3500, 3500-P Operation and Adjustment Instructions, Warni NG

Page 18

F: OPERATION AND ADJUSTMENT INSTRUCTIONS

STEP 2: Adjusting the Sensitivity Force — Sensitivity System force adjustment screws are located on the side rails of the Power Unit and can easily be adjusted with a screwdriver. Turn the screws CLOCKWISE for more force and COUNTERCLOCKWISE for less force.

 

 

CLOSE FORCE

 

 

 

ADJUSTMENT

 

104391

 

 

 

 

 

 

 

 

 

 

OPEN FORCE

ADJUSTMENT

WARNI NG

IMPROPER ADJUSTMENT OF SENSITIVITY SYSTEM FORCE COULD CAUSE ENTRAPMENT, INJURY OR DEATH. SET ADJUSTMENTS FOR JUST ENOUGH FORCE TO OPERATE THE DOOR RELIABLY, BUT NO STRONGER. Contact a service professional to correct any binding, sticking or other door problems. DO NOT OVER-ADJUST SENSITIVITY SYSTEM TO COMPENSATE FOR A POORLY WORKING DOOR.

STEP 3: Testing the Sensitivity Force — To test the Sensitivity System, start the Opener and grasp the bottom door handle halfway through the door's travel (opening or closing). When testing in the CLOSE direction, a second person will be needed to maintain pressure on the Push Button IF an Auxiliary Entrapment Protection Device has not yet been fitted. If a second person is unavailable, use a stiff cardboard carton placed in the door's downward path to indicate the force the Opener is exerting. If the force adjustment screws are properly set, the door should stop if opening, and reverse if closing without exerting undue pressure.

STEP 4: Testing the Opener’s Reversing System — To test the Opener's Reversing Feature at floor level, place a solid object 1-1/2" thick (such as a standard 2 X 4 board laid flat) on the ground where the center of the door will contact it. Close the door. If the down force adjustments are correct, the door will reverse within two seconds of contacting the object and travel to the Full Open position. If this does not occur, recheck the Limit Adjustments (Page 17) and Sensitivity Adjustments (Step 2 & 3, Above).

NOTE: Any time adjustments are

made to Limits or Sensitivity, YOU 104392

MUST RETEST THE OPENER FOR THE REVERSING FEATURE AT FLOOR LEVEL AS OUTLINED ABOVE.

WARNI NG

FAILURE TO TEST

REVERSING SYSTEM

COULD RESULT IN

DEATH OR SERIOUS

INJURY. TEST THIS

SYSTEM ONCE A MONTH

BY FOLLOWING

PROCEDURES OUTLINED

1 1/2” BLOCK OF WOOD LAID FLAT (2”X4”)

 

THE SENSITIVITY SYSTEM REVERSING TEST SHOULD BE

WARNI NG

PERFORMED MONTHLY TO ENSURE THAT THIS IMPORTANT

SYSTEM REMAINS IN PROPER ADJUSTMENT.

18

Image 18
Contents Series Table of Contents Product Features Optional FeaturesComponent Identification Tools RequiredAssembly Instructions StepImportant Installation To Reduce the Risk of Severe Injury AdjustmentInstalling the Operator Do not Attempt AdjustmentMounting the Front Bracket One High ARC Rise High ARC Rise Horizontal LineOne Piece Doors without Track Raise the opener Mount Power Head to CeilingSectional Doors and One Piece Doors with Track Mounting straps in the slots closest to FrontDoor ARM Connection and Installation Connect the standard wall Push Button provided to Mount at least 5 FT from the floor to prevent small childrenFastening Limit CAM to Chain Auxiliary Equipment Photosystem Unit is Within the Limit Marks on the Door JambConnect the Photosystem as follows Final Installation Final Alignment and TestInstallation of Radio Controls If the Door is Operating ParametersCheck with Your Local Building Inspector First ONE SECOND, and then Begin Moving Upward104390 Operation and Adjustment Instructions Warni NGTesting the All-Clear Photosystem Security Switch is GarageOperator Wiring Diagram Wiring Auxiliary Equipment Series Connection Receiver FirstInstallation Checklist Solution Troubleshooting GuideSymptom Probable CAUSE/SOLUTION Probable CauseAllstar Corporation Downingtown, PA