10. DIP SWITCH

10. DIP SWITCH

Note

All DIP switches are set to OFF at the time of shipment.

When changing DIP switch, the power must be off.

10-1. Panel DIP switch functions

 

 

 

1224S

 

 

 

 

 

 

 

 

 

 

 

 

DIP switch A

 

 

 

 

SW No.

 

When ON

A-1

After sewing is complete, the work clamp is raised by the operator and does not rise automatically.

 

 

 

 

Various setting combinations for DIP switch No. 2, No. 3 and No. 4 can be used to change the way the work clamp is raised and lowered.

The operation mode can be changed using the two-stage work clamp switch. (Special order)

SW

SW

SW

Type

Function of work clamp pedal

A-2

A-3

A-4

 

 

-

-

-

Pneumatic

Work clamp and presser foot rise and lower simultaneously.

 

 

 

 

 

ON

-

-

Pneumatic

Only work clamp rises and lowers; presser foot lowers when starting

switch is pressed.

 

 

 

 

-

ON

-

Pneumatic

For split-type presser foot, the left/right order changes alternately.

 

 

 

 

 

ON

ON

-

Pneumatic

Only work clamp rises and lowers; presser foot lowers when starting

switch is pressed.

 

 

 

 

-

-

ON

Pneumatic

Work clamp and presser foot rise and lower simultaneously.

 

 

 

 

 

ON

-

ON

Pneumatic

Lowers in the order right work clamp, left work clamp, presser foot;

reverse order when rising.

 

 

 

 

-

ON

ON

Pneumatic

Lowers in the order left work clamp, right work clamp, presser foot;

reverse order when rising.

 

 

 

 

ON

ON

ON

Pneumatic

Lowers in the order left and right work clamp, presser foot; reverse order

when rising.

 

 

 

 

41

BAS-341F, 342F

Image 48
Contents BAS-341F BAS-342F Safety Instructions Safety indications and their meaningsInstallation Environmental requirementsCleaning Maintenance and inspectionSewing 1971S Contents Changing Special Functions Name of Each Parts BAS-341FBAS-342F Specifications NeedleBefore setting up PreparationPositioning Tilting the sewing machine headConnecting the ground wire Installing the foot switchBelt tension Installing the spool stand Installing the programmer optionAdjusting the air pressure Lubrication Lubrication pointsInstalling the needle and running the sewing machine Correct USESelecting the needle and thread To turn the pulley by handThreading the upper thread Winding the lower thread Replacing the bobbin case and threading the thread Sewing conditions and thread tensionLower thread tension Upper thread tension Pretension tension Using the Operation Panel Explanation of panelIndicator Switch Using the floppy disk Compatible types of floppy diskSetting the floppy disk How to use the cleaning diskUsing the program R/W Read/Write switch If an error message is displayedClearing the error To Read a pattern to memoryUsing the Test switch Checking the sewing pattern Resuming operation from a stopping poingUsing the emergency stop switch Continuing sewing from a stopping pointAdjusting the sewing Speed control Changing the X-SCALE and Y-SCALE settingsUsing the bobbin thread counter Using production counter Using single split mode Shifting a stitch pattern Sewing Before starting sewingSewing operation 1942S Maintenance and Inspection Cleaning the shuttle hookLubrication Cleaning the control box air inlet port Draining the oilCleaning the eye guard Checking the needleAdjusting the needle bar height Adjusting the needle bar lift amountAdjusting the needle clearance Adjusting the driver needle guardAdjusting the shuttle race thread guide Adjusting the movable knife Replacing the movable and fixed knivesMovable knife Presser foot adjustment Adjusting presser foot lift to 3 5mm Adjusting presser foot lift to 5 8 mmChanging the presser foot lift Standard presser foot lift is 3 mm max mm Adjusting the wiper Adjusting the needle up stop positionChecking the input sensor and DIP switch input Clearing all memory settings Checking the input voltageDIP Switch Panel DIP switch functionsFeeding speed is switched to high speed DIP switches inside the control box DIP Switch Changing Special Functions and Using the Memory Switches Memory switches 00 0F Switch No When on Memo-10 Memory switches 20 2F Extended option outputSwitch No Possible Units Error Codes Error codes E.9 * E.F Gauge Parts List According to Subclasses Plate blank Troubleshooting Incorrect needle and shuttle hook timing Turn the sub-tension nut To adjust the tension Adjust the sub tension Sharpen or Replace Fixed knife Option Needle thread presser deviceAir wiper device 15-1, Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan. Phone