Roberts Gorden UHA[X][S] 75 Pressure Switch, Ignition Control, Axial Fan/Guard/Motor Assembly

Models: UHA[X][S] 75 UHA[X][S] 60 UHA[X][S] 100 UHA[X][S] 125 UHA[X][S] 30 UHA[X][S] 45

1 62
Download 62 pages 51.32 Kb
Page 53
Image 53
14.7 Pressure Switch

SECTION 14: REPLACEMENT PARTS

14.7 Pressure Switch

Pull off 3 way connector. Spring open plastic clips of mounting cradle. Replace with correct type of pressure switch for model. The pressure switches are color coded for each pressure setting. Carry out a start-up after working on or changing a pressure switch. See Page 29, Section 10.

.

MODEL

UHA[X][S] 30

UHA[X][S] 45

UHA[X][S] 60

UHA[X][S] 75

UHA[X][S] 100

UHA[X][S] 125

 

 

 

 

 

 

 

Pressure Switch

90439801

90439810

90439802

90439810

90439810

90439803

Kit P/N

 

 

 

 

 

 

 

Color Code

pink

black

yellow

black

black

gray

 

 

 

 

 

 

 

Set Point in. wc

.23

.35

.32

.35

.35

.41

 

 

 

 

 

 

 

Pressure Switch

90439850

90439850

90439850

90439850

90439850

90439850

Snap Ring P/N

 

 

 

 

 

 

 

14.8 Ignition Control

The control mounts to the heat exchanger plate. Pull out ignition cable and wiring from board, noting their positions. Release the four mounting standoffs. Refit in reverse. Ensure correct location of ignition cable and all other wiring.

14.9 Axial Fan/Guard/Motor Assembly

The axial fan unit for the heater is supplied completely assembled and balanced.

MODEL

UHA[X][S] 30

UHA[X][S] 45

UHA[X][S] 60

UHA[X][S] 75

UHA[X][S] 100

UHA[X][S] 125

 

 

 

 

 

 

 

Axial Fan Guard

91901103

91901103

91901102

91901102

91901102

91901102

 

 

 

 

 

 

 

Axial Fan Motor

90600104

90600104

90600105

90600105

90600106

90600106

 

 

 

 

 

 

 

Axial Fan Blade

90709004

90709003

90709002

90709001

90709001

90709001

 

 

 

 

 

 

 

47

Page 53
Image 53
Roberts Gorden UHA[X][S] 75, UHA[X][S] 45, UHA[X][S] 30 Pressure Switch, Ignition Control, Axial Fan/Guard/Motor Assembly