SECTION 12: SERVICING

 

Combustion Air Intake

Intake pipe and inlet must be intact. Look for obstructions, cracks on the pipe,

Pipe

gaps in the sealed areas or corrosion.

 

The area must be free of dirt and dust.

 

Clean and reinstall as required.

 

 

Heat Exchanger

Make sure there are no cracks.

 

Make sure there is no sagging, bending or distortion.

 

Clean or replace as required.

 

See Page 22, Section 8.

 

 

Gas Line and Shut-off

Check for gas leaks. See Page 22, Section 8.

Valves

 

 

 

 

Burner Observation

Make sure it is clean and free of cracks or holes.

Window

Clean and replace as required.

 

 

 

Flue Blower Scroll, Wheel

Compressed air or a vacuum cleaner may be used to clean dust and dirt.

and Motor

 

 

 

 

Inshot Burners and

Clear obstructions (even spider webs will cause problems).

Orifices

Carefully remove any dust and debris from the burner.

 

 

 

Direct-Spark Igniter

Replace if there are cracked ceramics, excessive carbon residue, or erosion

 

of the electrode.

 

The electrode gap should be 1/8" (3.2 mm).

 

 

Thermostat

There should be no exposed wire or damage to the device or wiring.

 

See Page 29, Section 10.

 

 

Suspension Points

Make sure the heater is hanging securely.

 

Look for signs of wear on the suspension materials or ceiling.

 

See Page 11, Figure 5.

 

 

Silicone Tubing

Ensure tight, secure fit on all pressure fittings at pressure switch,

 

burner partition, and blower outlet.

 

 

Gas Valve

Verify that cap covering pressure regulator adjustment screw is secure and

 

has not been tampered with.

 

Verify all wiring connections.

 

 

Condensate Drain

Flush drain and clear any obstructions.

(when installed)

 

 

 

 

Wall Tag

If wall tag is present, make sure it is legible and accurate. Please contact

 

Roberts Gordon LLC or ROBERTS GORDON® independent distributor if you

 

need a wall tag. See Page 5, Section 2.1.

 

 

 