Roberts Gorden UHA[X][S] 100 Heat Exchanger, Louver and Louver Springs, Horizontal, Vertical

Models: UHA[X][S] 75 UHA[X][S] 60 UHA[X][S] 100 UHA[X][S] 125 UHA[X][S] 30 UHA[X][S] 45

1 62
Download 62 pages 51.32 Kb
Page 51
Image 51
14.4 Heat Exchanger

SECTION 14: REPLACEMENT PARTS

14.4 Heat Exchanger

The heat exchanger consists of a four-pass design with 1.5" outer diameter [aluminized steel][409 stainless steel] tube. The tube plates are made of [aluminized steel][409 stainless steel]. The tube supports are made of [galvannealed steel] [409 stainless steel].

14.5 Louver and Louver Springs

Horizontal

Vertical

Louvers

Louvers

Install Vertical Louver Brackets (top and bottom) with supplied

Install Vertical screws.

Louver Brackets (top and bottom) with supplied screws.

14.5 Louver and Louver Springs Push in Louver and compress

spring to remove

(opposite end first)

spring to remove

For models UHA[X][S] 60 and UHA[X][S] 75, horizontal louvers are (opposite end first)

Install Vertical Louvers and Springs into Brackets

with Springs at Top

Install Vertical Louvers and Spring into Brackets with Springs at Top

re-used.

Description

UHA[X][S]

UHA[X][S]

UHA[X][S]

30 - 45

60 - 75

100 - 125

 

Horizontal Louvers P/N

 

11111900

 

Spring P/N

 

91901200

 

Quantity

3

5

7

Description

Part Number

Qty.

Vertical Louver Kit UHA[X][S] 30

12011003K

 

& UHA[X][S] 45

 

 

 

 

 

 

Vertical Louver Bracket

-

2

UHA[X][S] 30 - 45 Vertical Louvers

-

4

Louver Spring

-

5

Instruction Sheet

-

2

#10 Screw

-

1

#10 Screw

-

4

Description

Part Number

Qty.

Vertical Louver Kit UHA[X][S] 60

12011005K

 

& UHA[X][S] 75

 

 

 

 

 

 

Vertical Louver Bracket

-

2

UHA[X][S] 60 - 75 Vertical Louvers

-

5

Instruction Sheet

-

1

#10 Screw

-

4

Description

Part Number

Qty.

Vertical Louver Kit UHA[X][S] 100 &

12011004K

 

UHA[X][S] 125

 

 

 

Vertical Louver Bracket

-

2

UHA[X][S] 100 - 125 Vertical Louvers

-

5

Instruction Sheet

-

1

#10 Screw

-

4

45