TABLE OF CONTENTS
SECTION 1: Heater Safety | 1 | SECTION 10: Operation and Maintenance | 29 | ||
1.1 Manpower Requirements | 1 | 10.1 | 29 | ||
1.2 Safety Labels and Their Placement | 1 | 10.2 | Begin | 29 | |
SECTION 2: Installer Responsibility | 5 | 10.3 | Complete | 32 | |
2.1 | Wall Tag | 5 | SECTION 11: User Instructions | 33 | |
2.2 | Corrosive Chemicals | 5 | 11.1 User Instructions | 33 | |
2.3 | National Standards and Applicable Codes | 5 | 11.2 Heater Operation | 33 | |
SECTION 3: Critical Considerations | 6 | 11.3 Common User Controls | 33 | ||
3.1 | Basic Information | 6 | 11.4 Lighting Instructions | 33 | |
3.2 | Manufactured Units | 6 | 11.5 Simple Troubleshooting | 34 | |
3.3 | Location and Suspension | 6 | SECTION 12: Servicing | 35 | |
3.4 | Minimum Required Installation Clearances | 6 | 12.1 | Servicing Instructions | 35 |
3.5 | Clearances to Combustibles | 6 | 12.2 | Burner Maintenance | 35 |
3.6 | Ventilation | 6 | 12.3 | Fan/Motor Assembly Maintenance | 35 |
3.7 | Gas Supply | 7 | 12.4 | Heat Exchanger Maintenance | 35 |
3.8 | Electrical Supply | 7 | 12.5 | Gas Valve Maintenance | 35 |
3.9 | Vent | 7 | 12.6 | Flue Blower | 35 |
SECTION 4: National Standards and Applicable Codes | 8 | 12.7 | Venting and Air Intake Pipe | 36 | |
4.1 | Gas Codes | 8 | 12.8 | Maintenance Checklist | 36 |
4.2 | Aircraft Hangars | 8 | SECTION 13: Troubleshooting | 38 | |
4.3 | Parking Structures and Repair Garages | 8 | 13.1 | General | 38 |
4.4 | Electrical | 8 | 13.2 | Troubleshooting For Automatic Ignition |
|
4.5 | Venting | 8 |
| Burner Systems | 39 |
4.6 | High Altitude | 9 | 13.3 | Troubleshooting for Flame Supervision System | 40 |
SECTION 5: Major Components | 10 | 13.4 | Troubleshooting for Gas Valves | 41 | |
5.1 | General | 10 | 13.5 | Troubleshooting for Flue Blower | 41 |
5.2 | Shelf Mounting and Suspension | 10 | SECTION 14: Replacement Parts | 42 | |
5.3 | Wall Mounting | 10 | 14.1 | Gas Valve | 42 |
SECTION 6: Venting | 14 | 14.2 | Burner Compartment | 43 | |
6.1 | Changing Vent and Air Intake Orientation | 14 | 14.3 | Ignition Electrode and Flame Probe | 44 |
6.2 | Venting | 14 | 14.4 | Heat Exchanger | 45 |
6.3 | Vent Installation | 14 | 14.5 | Louver and Louver Springs | 45 |
6.4 | Unvented Operation | 15 | 14.6 | Flue Blower Vertical Installation | 46 |
6.5 | Horizontal Venting | 15 | 14.7 | Pressure Switch | 47 |
6.6 | Vertical Venting | 16 | 14.8 | Ignition Control | 47 |
6.7 | Length Requirements | 16 | 14.9 | Axial Fan/Guard/Motor Assembly | 47 |
6.8 | Vent Material | 16 | 14.10 Limit Switches | 48 | |
6.9 | Replacing an Existing Heater in a Venting System .... | 16 | SECTION 15: Specifications | 49 | |
SECTION 7: Air Supply | 21 | 15.1 | Dimension Data | 49 | |
7.1 Separated Combustion Installation | 21 | 15.2 | General Technical Data Table (All Models) | 50 | |
7.2 Unvented Installation | 21 | 15.3 | Technical Data Table (All Models) | 50 | |
7.3 Building Ventilation | 21 | SECTION 16: ROBERTS GORDON® COMBAT® |
| ||
7.4 Outside Combustion Air Supply | 21 |
| 53 | ||
SECTION 8: Gas Piping | 22 |
|
|
| |
8.1 | Connections | 22 |
|
|
|
SECTION 9: Wiring | 23 |
|
|
| |
9.1 | Positioning Thermostats | 23 |
|
|
|
9.2 | Low Voltage Thermostat with One Heater | 23 |
|
|
|
9.3 | Multiple Heater Wiring 30 - 45 | 24 |
|
|
|
9.4 | Multiple Heater Wiring 60 - 125 | 25 |
|
|
|
9.5 | Internal Wiring Diagram | 26 |
|
|
|
9.6 | Ladder Wiring Diagram | 27 |
|
|
|
9.7 | Electrical Connection to the Heater | 28 |
|
|
|
©2008 Roberts-Gordon LLC
All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the written permission of