Figure 9: Vent and Roof Detail

SECTION 6: VENTING

are located and other spaces of the building. Turn on clothes dryers and any exhaust fans, such as range hoods and bathroom exhausts so that they shall operate at maximum speed. Do not operate a summer exhaust fan. Close fireplace dampers.

4.Follow the lighting instructions. Place the appliance being inspected in operation. Adjust thermostat so that the appliance will operate continuously.

5.For any appliance having a draft hood, test for draft hood appliance spillage at the draft hood relief opening after 5 minutes of main burner operation. Use the flame of a match or candle.

6.After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas-burning appliances to their previous conditions of use.

7.If improper venting is observed during any of the above tests, the venting system must be corrected by a contractor qualified in the installation and service of gas-fired equipment or your local gas supplier. If the venting must be resized, use appropriate tables in (US) Appendix G of NFPA 54/ANSI Z223.1 - latest revision, National Fuel Gas Code (US) or Standard CSA B149.1 Natural Gas and Propane Installation Code (Canada) to determine minimum size. All vent corrections

must be in accordance with the appropriate local codes and the NFPA 54/ANSI Z223.1 - latest revision, National Fuel Gas Code (US) or Standard CSA B149.1 Natural Gas and Propane Installation Code (Canada).

Figure 9: Vent and Roof Detail

Figure 10: Standard Vented Heater - Vertical and Horizontal Vent Termination

 

 

 

Vent Terminal

NOTE: Vent supports not

 

 

 

shown.

 

 

 

 

 

 

Flashing

 

 

 

 

(By Others)

 

 

 

 

Listed

 

 

 

 

Thimble

 

 

 

(2" [5 cm]

 

Listed

 

Clearance)

 

 

 

4" (10 cm)

 

Thimble

 

 

 

(2" [5 cm] Clearance)

 

 

Diameter Vent

 

 

 

 

Vertical

Horizontal

Flashing

 

 

Option

(By Others)

 

 

 

Option

 

 

 

 

 

Vent

 

 

 

 

Terminal

 

 

 

Vent

 

 

 

 

 

12" (31 cm)

 

 

 

 

Minimum

Model

Vent Diameter

Part Number

 

 

UHA[X] 30 - 125

4" (10 cm)

90502102

 

 

 

 

 

 

17

Page 23
Image 23
Roberts Gorden UHA[X][S] 75, UHA[X][S] 45, UHA[X][S] 30, UHA[X][S] 125 Vent and Roof Detail, Vertical, Horizontal, Option