Kenmore 350 Series, 625.393560 Connect Valve and Salt Tank Drains, Connect the Valve Drain Hose

Page 14

Connect Valve and Salt Tank Drains

CONNECT THE VALVE DRAIN HOSE

Take a length of 3/8” inside diameter drain tubing and attach one end to the drain fitting. See Fig. 16. Use a tube clamp to hold it in place. Put the other end of the tubing over a floor drain, into a laundry tub, standpipe, or other suitable drain. Check your local codes.

Leave an air gap of about 1-1/ 2'' between the end of the hose and the drain. This gap is needed so you don’t get a backflow of sewer water into the softener. Do not put the end of the hose into the drain or con- nect without the air gap.

Place and support the hose so it does not kink or have sharp bends. Secure the hose end so water pressure does not cause the hose to “whip”. Tie or wire it in place. Do not pinch the hose shut. The softener will not work if this drain hose is pinched, plugged, closed or restricted in any way. Direct drain flow down into drain from drain line as flow could possibly over shoot the drain cover.

Keep the hose lower than the drain fitting. In some homes, to get to a drain you must raise the hose and run it overhead. If you need an overhead drain, do not raise the hose more than 8' above the floor. A copper drain tube is best to use.

COPPER DRAIN TUBE: Local plumbing codes may require the use a copper valve drain tube. A copper

tube is also best to use for an overhead drain. Use a copper drain tube if the softener is installed outside, or in the sunlight. Heat from the sun can soften, flatten and close up some kinds of tubes.

To adapt a copper drain tube to the softener, buy a compression fitting (1/4'' female pipe threads x 1/2'' O.D. tube) and tubing from your local hardware store.

CONNECT SALT TANK OVERFLOW TUBING

1.Locate the rubber grommet, tube adaptor and tube clamp (see Fig. 16) that are in the parts bag.

2.Push the grommet into the hole in the salt tank wall so half is inside and half is outside.

3.Push the bigger end of the tube adaptor into the grommet.

4.Push one end of a length of 3/ 8'' I.D. tubing onto the tube adaptor, using the tube clamp to hold it in place.

5.Put the other end of the tubing over the floor drain.

IMPORTANT: Overflow water must run downward through the tubing. Do not raise the tubing higher than the grommet and tube adaptor. See Fig. 16.

IMPORTANT: Do not connect to the valve drain hose you installed in step 1. Both drains must have a separate hose or tube.

NOTE: Overflow drain tubing is available from Sears. See parts list in back of manual.

Tube

Clamp

Drain

Fitting

Grommet Tube

Adaptor

Tube

Clamp

NOTE: Overflow drain tubing is avail- able from Sears, Item No. 42-3433 (20 ft).

Overflow Drain Tubing

 

 

 

1/4 NPT Threads

 

 

 

 

 

Barbs

 

 

 

 

 

 

 

1/2” Outside Diameter

 

 

Clip

 

 

Copper Tube

 

 

 

 

(Not furnished)

 

 

 

 

 

 

 

Cut Barbs from Drain

 

 

 

 

 

Fitting (Pull clip and

 

 

 

 

remove fitting from valve.)

 

 

 

 

 

 

Comp Fitting. 1/4 NPT x

 

 

 

1/2 in. O.D. Tube

 

 

 

 

 

(Not furnished)

 

 

 

 

 

 

 

 

 

 

 

 

To drain

 

 

 

 

 

 

point other

STANDPIPE

 

 

 

than floor

 

 

 

 

 

 

 

 

 

 

drain.

 

 

 

Valve Drain Hose

Support

 

 

 

tubing in

 

 

 

 

 

 

 

1-1/2”

 

 

 

place as

 

 

 

 

 

Air Gap

 

 

 

needed.

 

 

 

Tie or Wire

1-1/2”

 

 

 

 

Tubing in Place Air Gap

 

1-1/2” Air Gap

FLOOR DRAIN

LAUNDRY TUB

FIG. 16

Questions? Call The Kenmore Water Line 1-800-426-9345

14

Image 14
Contents Repair or Parts ? Call toll free Save this ManualDisclaimer of implied warranties limitation of remedies ONE Year Limited Warranty on Water SoftenerTEN Year Limited Warranty Against Leaks Table of Contents Facts and Figures to KeepSafety Guides Small Parts Unpack and Check Your CartonParts Descriptions Inspect ShipmentPlan Your Installation Plan Your InstallationProper Order to Install Water Treating Equipment Tools NeededWhere to Install the Water Softener Soft, HotSuggested Slab Foundation Installation Draw in Your Pipes and FittingsOUT PIPE, FITTINGS, Other Materials NeededRead Before Beginning Installation Before Installing Checks & Tests Bypass Valve Install Plastic Bypass Valve Assemble Inlet Outlet ADAPTORS, or Plastic Bypass Valve Inlet and Outlet Threaded AdaptorsInstalling 3 Valve Bypass and Pipes Install 3-Valve BypassInstalling Holding Clips Valve BypassTypical Soldering Connections Locate Water Softener and Connect PipesMove Softener Into Place Position Softener Into PlaceConnect Salt Tank Overflow Tubing Connect Valve and Salt Tank DrainsConnect the Valve Drain Hose Single Bypass Leak TestHouse Main Water Shutoff Valves Leak TestElectrical Requirements Water Meter Jumper WireConnecting Transformer Cold Water Pipe GroundingInstall Covers Install Covers and Restart Water HeaterProgram The Timer Program the TimerSET Regeneration Time SET Present Time of DAYSET Water Hardness Number Sanitize Your Water Softener AS Follows Sanitize The Water SoftenerSanitize the Water Softener Water Softening Salt with Iron Removing Additives Adding Salt To The Storage TankAdding Salt to the Storage Tank Check List of STEP-BY-STEP Guides to Install Check ListFaceplate Timer Features 12 / 24 Hour Clock California Efficiency RequirementWater Flow Through the Softener KENMORE’S Ultra Cleansing Feature Recharge Time Remaining and Valve Position IndicatorsError Code Program MemoryHow Your Water Softener Works Water Flow Through Softener in ServiceSoft Water Service and Regeneration Water Flow Through Softener in FillWater Flow Through Softener Brining and Brine Rinse Water Flow Through Softener in BackwashElectronics Water Flow Through Softener Fast RinseAutomatic Bypass Salt Bridge Care Of Your Water SoftenerSalt Bridge Nozzle & Venturi Keeping the Water Softener CleanIron from Resin BED Drain ALL Water from Softener Protect the Water Softener from FreezingProblem Cause Correction Checklist to Help YOU Save MoneyBypass Valves SpecificationsModel 38356 Timer Code S Model 39356 Timer Code S InchesOther Specifications Faceplate Service Tech InformationWiring Schematic Always Make These Initial Checks FirstProcedure for Removing Error Code from Faceplate Possible Defect CodeOther Information Troubleshooting Valve Position IndicatorsTimer PWA Replacement ModelCycle Flow Rates Gallons PER MIN Brine Valve Float SettingManual Advance Regeneration Check Assembly Rotary Valve ServiceDisassembly To Relieve PressureBrining and Brine Rinse Cycle Water Flow Through the Softener Valve Service CycleFill Cycle Backwash Cycle Water Flow Through the Softener Valve Backwash CycleFast Rinse Cycle Fast Rinse CycleExploded View Part Number Part Description Parts ListWater Softener Complete Inlet Outlet Grounding Clamps Brine Valve Assembly Seal Key Part Number Part Description Get it fixed, at your home or ours