Kenmore 625.38306 owner manual No. Number Part Description

Page 95

Key Part

No. Number Part Description

1 7224087 Screw, #8-32 x 1" (2 req.)

27286039 Motor (incl. 2 ea. of Key No. 1)

30900857 Screw, #6-20 x 3/8" (2 req.)

47231385 Motor Plate

50503288 Bearing

67284964 Cam and Gear

77142942 Clip (Drain)

80900431 Tubing Clamp •

97024160 Drain Hose Adaptor

107170327 O-Ring, 5/8" x 13/16"

11 0501228 Flow Plug

127170238 O-Ring, 7/16" x 5/8"

137170212 O-Ring, 3/4" x 15/16"

147082087 Wave Washer

157199232 Rotor & Disc

167170246 O-Ring, 3-3/8" x 3-5/8"

177116713 Clip (4 req.) •

187278442 Installation Adaptor, 1" NPT (2 req.) •

197170288 O-Ring (2 req.) •

20 7134224 Rotor Seal

217170204 O-Ring, 3/8" x 9/16"

227092642 Plug (Drain Seal)

237129889 Spring

242204101 Turbine Support and Shaft

257117858 Turbine

267082053 Valve Body

277081764 Seal (Nozzle & Venturi)

287081201 Retainer (Nozzle & Venturi)

297170319 O-Ring, 1/4" x 3/8" (2 req.)

30 7081104 Nozzle & Venturi Housing

Key

Part

 

 

No.

Number

Part

Description

31

1202600

Nut-

Ferrule

32

7095030

Cone Screen

331148800 Flow Plug, .3 gpm

347187772 Nozzle & Venturi Gasket Kit

-- 7204362 Gasket (only)

350521829 Flow Plug, .1 gpm

367146043 Screen

377167659 Screen Support

387170262 O-Ring, 1-1/8"x 1-3/8"

397199729 Cap

407309803 Wire Harness (Sensor)

417085263 Valve Cover

427074123 Screw, #10-14 x 2 (5 req.)

437077472 Expansion Pin

447030713 Switch

457117816 Spacer

467070412 Screw, #4-24 x 1-1/8 (flat head)

477254260 Installation Adaptor Kit, (includes 2 copper tubes, nuts, clips & washers) "k

7187065 Nozzle & Venturi Assembly (incl. Key Nos. 30 & 32-39)

7129716 Seal Kit (incl. Key Nos. 12, 13, 16, 20, 21 & 27)

7139999 Drain Tubing, 3/8" I.D. x 20 ft.

42-34405 Flexible Connectors, 3/4"

42-34407 Flexible Connectors, 1"

7123613 Silicone Grease (for O-Rings)

•A'Not included

Not illustrated

Included in parts bag, see page 43.

Key

Part

 

 

No.

Number

Part Description

97

0502206

Retainer

Ring

98

7271262

Bypass

Body

lO0

99

17

98

997105013 O-Ring, 13/16" x 1" (4 req.)

100 7129855 Stem

101

7170288

O-Ring,

15/16" x 1-3/16" (2 req.)

7278434

Bypass

Valve (Complete) •

10197

Questions? Call The Kenmore Water Line 1-800-426-9345

47

Image 95
Contents Save this Manual Water SoftenerTEN Year Limited Warranty Against Leaks ONE Year Limited Warranty on Water SoftenerQuestions? Questions? Call The Kenmore Water Line Inspect Shipment Parts Descriptions SmallPipe Proper Order to Install Water Treating EquipmentPlan Your Installation Tools NeededWhere to Install the Water Softener Typical InstallationDraw Your Pipes Fittings Suggested Slab Foundation InstallationClip Adding a pressure reducing valve may reduce the flow Before Installing Checks & TestsInlet and Outlet Threaded Adaptors Assemble Inlet Outlet ADAPTORS, or Single Bypass ValveBypass Valve Bypass Valve Turned Downward Installing Holding ClipsValve Bypass Connect the Softener Move Softener Into PlaceTypical Soldering Connections Position Softener Into PlaceConnect Salt Tank Overflow Tubing Connect the Valve Drain HoseLeak Test House Main Water Shutoff ValvesSingle Bypass Cold Water Pipe Grounding Water Meter Jumper WireConnecting Transformer Electrical Power Outlet for Your SoftenerRestart the Water Heater Install CoversInstall Covers SET Present Time of DAY Program the TimerSET Salt Level SET Water Hardness NumberHardness Number SET Regeneration TimeSanitize Your Water Softener AS Follows Sanitize the Water SoftenerRemoving Additives Water Softening Salt with IronUnit plugged Into a continuously live outlet? Check List of STEP-BY-STEP Guides to InstallSalt Monitor System Recharge NOWRecharge Tonight Program Memory Efficiency ModeError Code Regeneration Soft Water Service and RegenerationService Water Flow Through Softener in Backwash Water Flow Through Softener Brining and Brine RinseElectronics Soft Water Service and Regeneration Automatic BypassWater Flow Through Softener Fast Rinse Salt Bridge Salt BridgeIron from Resin BED Cleaning Nozzle & Venturi Keeping the Water Softener CleanProtect the Water Softener from Freezing Drain ALL Water from SoftenerCorrection ProblemcauseChecklist to Help YOU Save Money Bypass Valves Model no .383060 Timer Code SPressure Drop PSI vs. Flow Rate GPM Eration Check Wiring SchematicAlways Make These Initial Checks First Manual Initiated Electronics Diagnostics Possible Problem Code Most Likely Less LikelyProcedure for Removing Error Code From Faceplate Other Information Troubleshooting Valve Position IndicatorsTimer PWA Replacement MAX. Fast Rinse Cycle Flow Rates Gallons PER MINBrine Rinse MAX. BackwashServicing the Valve DisassemblyAssembly To Relieve PressureBrining and Brine Rinse Cycle Valve Service CycleWater Flow Through the Softener Fill CycleFast Rinse Cycle Valve Backwash CycleFast Rinse Cycle Backwash CycleQuestions? Call The Kenmore Water Line LiO Water Softener Complete KeyNoInlet Outlet Grounding Clamps Key No. Part Number Part Description Brine Valve Assembly11 10 Wear-Strip Seal Cross-Section View No. Number Part Description Your Home Water Softener Warranty on Water Softener Questions? Questions? Call The Kenmore Water Line Parts Descriptions Small DeFa ce s Typical Installation Suggested Slab Foundation Installation Clip Before Installing Checks & Tests Assemble Inlet Outlet ADAPTORS, or Single Bypass Valve Valve Bypass Move Softener Into Place Connect the Valve Drain Hose House Main Water Shutoff Valves Installgroundingclampbetween Thesoftenerinand OUT Pipes Install Covers PMI UP or Down button in changes the display twice each second Sanitize the Water Softener Addingsalttothe Storagetank Check List of STEP-BY-STEP Guides to Install 312 Nun @ Questions? Call The Kenmore Water Flow Through Softener Brining and Brine Rinse Water Flow Through Softener Fast Rinse Salt Bridge Iron from Resin BED Drain ALL Water from Softener Problemcause Bypass Valves Pressure Drop PSI vs. Flow Rate GPM Faceplate Procedure for Removing Error Code From Faceplate Sc,l Root sto Rotaryvalveservice Water Flow Through the Softener Valve Backwash Cycle Questions? Call The Kenmore Water Line LiO KeyNo Inlet Outlet Grounding Clamps Brine Valve Assembly 11 10 Wear-Strip Seal Cross-Section View No. Number Part Description Your Home