Mitsubishi Electronics Outlines and Dimensions, MSZ-FA25VA E1 MSZ-FA35VA E1, Indoor Unit

Page 7

5

OUTLINES AND DIMENSIONS

MSZ-FA25VA - E1 MSZ-FA35VA - E1

Unit : mm

INDOOR UNIT

780

298

53.5

624.5

5819

11o26 Oblong hole

11o20 Oblong hole

 

 

 

 

 

Installation plate

55

225

 

225

 

55

 

14

 

 

 

 

 

 

 

 

 

 

215

 

 

 

 

 

214

234

273.5

287.5

41.5

 

155

 

155

 

 

42.5

 

3

55

335

 

320

 

70

 

Indoor unit

 

Air in

 

 

 

Wall hole

[65

 

 

 

 

 

 

 

 

 

7 or more

198

5

Installation plate

 

 

 

 

 

 

 

{

Liquid line [6.35 - 0.5m

 

 

 

 

Gas line [9.52 - 0.43m

 

 

 

 

Insulation [35 O.D

 

 

 

 

 

[19 I.D

 

 

 

 

 

 

 

 

100

 

 

 

 

Drain hose [16

 

 

 

 

 

(Connected part O.D)

 

90

 

 

 

Insulation [28

102

 

 

 

 

 

106

 

 

 

 

 

 

 

 

 

 

 

 

 

Air out

 

 

 

 

 

 

 

 

159

Wireless remote controller

Required space (Indoor unit)

75 or more

75 or more

10 or more

 

55 or morew

wIn case of left, left back, or left under piping (using spacer), 113 or more

7

Image 7
Contents MSZ-FA25VA E1 MSZ-FA35VA E1 ContentsGeneralized stepping motor Technical ChangesFront panel opening/closing output gear See control operation Wash reset switch Open Closed Receiving sectionPart Names and Functions Indoor Unit MSZ-FA25VA MSZ-FA35VARemote Controller MSZ-FA25VA E1 MSZ-FA35VA E1 AccessoriesSpecifications and rating conditions of main electric parts SpecificationWhen outdoor unit is MXZ type MSZ-FA25VA E1 Noise Criteria CurvesMSZ-FA35VA E1 Unit mm Outlines and DimensionsMSZ-FA25VA E1 MSZ-FA35VA E1 Indoor UnitMSZ-FA35VA E1 Indoor Unit Wiring DiagramRefrigerant System Diagram MSZ-FA25VA E1 Indoor UnitOperation Service FunctionsHow to modify the remote controller P.C. board Remote controller model KM05ARemote controller Troubleshooting Remove InstallOutdoor Unit MXZ series Information for Multi System AIR ConditionerOFF Failure mode recall functionTo identify the error.Refer to 9-6.For G OFF Indoor unit failure mode tablePlasma Deodorizing Plasma AIR PurifyingStart Instruction of troubleshooting· Flashing of Power lamp indicates abnormalities Troubleshooting check tableAIR PlasmaPurifying Trouble criterion of main parts When Power lamp flashes 3-time Indoor fan does not operate Troubleshooting flowCheck of indoor fan motor Check of remote controller and receiver P.C. board Indoor electronic control P.C.Board LED How to check mis-wiring and serial signal errorCheck of installation of the horizontal vane Plasma Deodorizing 0V? Safety Deviceplasma UnitAIR Purifying 0V? Continuously flash?Indoor unit and outdoor unit do not operate Check of auto front panelYes Electromagnetic noise enters into TV sets or radiosIndoor electronic control P.C. board Test point diagram and voltagePower monitor receiver P.C. board Plasma power P.C. boardRemoving the panel Photo Disassembly InstructionsRemoving the electrical box Operating Procedure PhotosFan Removing the horizontal vane motor unit PhotoRemoving the vertical vane motor unit Photo Removing the indoor fan motor and the line flow PhotoRemoving the plasma power P.C. board Photo Accessory and Remote Controller Parts ListMotor Receiver P.C Board Holder Safety PlasmaIndoor Unit Electrical Parts and Functional Parts Indoor Unit Heat Exchanger504 Symbol Qty/unit Part name WiringDiagram E02 509Deodorizing Ceramic Filter Optional PartsPage Specifications subject to change without notice