Mitsubishi Electronics MSZ-FA35VA Symbol Qty/unit Part name Wiring, Diagram E02, 509, 504, 702

Page 37

11-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS

 

 

 

 

 

Symbol

Q'ty/unit

 

 

 

 

 

 

 

 

 

No.

Part No.

Part name

in Wiring

MSZ-FA25VA- E1

MSZ-FA35VA- E1

Remarks

 

 

 

 

 

Diagram

(WH)

(WH)

 

 

 

 

 

 

 

 

 

 

1

E02

751

509

BEARING MOUNT

 

1

1

 

2

E02

001

504

SLEEVE BEARING

 

1

1

 

3

E02

897

702

DRAIN HOSE

 

1

1

 

4

E02

913

235

NOZZLE ASSEMBLY

 

1

1

 

5

E02

897

303

VANE MOTOR UNIT (HORIZONTAL)

MV1

1

1

UP & DOWN

6

E02

897

316

INTERLOCK SWITCH(FAN)

 

1

1

 

7

E02

913

303

VANE MOTOR UNIT (VERTICAL)

MV2

1

1

RIGHT & LEFT

8

E02

913

040

HORIZONTAL VANE

 

1

1

 

9

E02

127

382

FUSE

F11

1

1

3.15A

10

E02

661

385

VARISTOR

NR11

1

1

 

11

E02

913

095

POWER MONITOR RECEIVER P.C. BOARD HOLDER

 

1

1

 

12

E02

913

391

i-see Sensor

RR

1

1

 

13

E02

914

303

i-see Sensor MOTOR

MT

1

1

 

14

E02

897

784

VA CLAMP

 

1

1

 

15

E02

897

780

TERMINAL BLOCK COVER

 

1

1

 

16

E02

897

779

TERMINAL BLOCK HOLDER

 

1

1

 

17

E02

913

375

TERMINAL BLOCK

TB

1

1

 

18

E02

913

452

ELECTRONIC CONTROL P.C. BOARD W1

 

1

 

AUTO RESTART

E02

914

452

ELECTRONIC CONTROL P.C. BOARD W1

 

 

1

AUTO RESTART

 

 

 

19

E02

897

308

ROOM TEMPERATURE THERMISTOR

RT11

1

1

 

20

E02

913

307

INDOOR COIL THERMISTOR

RT12, RT13

1

 

 

E02

914

307

INDOOR COIL THERMISTOR

RT12, RT13

 

1

 

 

 

 

21

E02

913

782

SWITCH HOLDER

 

1

1

 

22

E02

897

300

INDOOR FAN MOTOR W2

MF

1

1

RC0J40-

23

E02

897

333

MOTOR BAND

 

1

1

 

24

E02

898

303

FRONT PANEL DRIVING MOTOR

MP

1

1

 

25

E02

897

302

LINE FLOW FAN

 

1

1

 

26

E02

913

775

PLASMA ELEMENT HOLDER

 

1

1

 

27

E02

913

776

PLASMA UNIT COVER

 

1

1

 

28

E02

913

777

PLASMA ELECTRICAL BOX

 

1

1

 

29

E02

897

440

PLASMA POWER P.C. BOARD

 

2

2

 

30

E02

898

316

SAFETY DEVICE (PLASMA UNIT)

 

1

1

 

31

E02

913

774

PLASMA AIR PURIFYING FILTER UNIT

PLASMA_A

1

1

 

32

E02

914

774

PLASMA DEODORIZING FILTER UNIT

PLASMA_D

1

1

 

W1 Including SW P.C. BOARD and POWER MONITOR RECEIVER P.C. BOARD

W2 Including FAN MOTOR RUBBER MOUNT (2 PCS/SET)

11-4. INDOOR UNIT HEAT EXCHANGER

33

E02

913

620

INDOOR HEAT EXCHANGER

 

1

 

 

E02

914

620

INDOOR HEAT EXCHANGER

 

 

1

 

 

 

 

 

34

E02

815

666

UNION (GAS)

 

1

1

{9.52

35

E02

151

667

UNION (LIQUID)

 

1

1

{6.35

37

Image 37
Contents MSZ-FA25VA E1 MSZ-FA35VA E1 ContentsGeneralized stepping motor Technical ChangesFront panel opening/closing output gear Part Names and Functions Wash reset switch Open Closed Receiving sectionIndoor Unit MSZ-FA25VA MSZ-FA35VA See control operationRemote Controller MSZ-FA25VA E1 MSZ-FA35VA E1 AccessoriesSpecifications and rating conditions of main electric parts SpecificationWhen outdoor unit is MXZ type MSZ-FA25VA E1 Noise Criteria CurvesMSZ-FA35VA E1 MSZ-FA25VA E1 MSZ-FA35VA E1 Outlines and DimensionsIndoor Unit Unit mmRefrigerant System Diagram Wiring DiagramMSZ-FA25VA E1 Indoor Unit MSZ-FA35VA E1 Indoor UnitHow to modify the remote controller P.C. board Service FunctionsRemote controller model KM05A OperationRemote controller Troubleshooting Remove InstallOutdoor Unit MXZ series Information for Multi System AIR ConditionerOFF Failure mode recall functionTo identify the error.Refer to 9-6.For G Plasma Deodorizing Indoor unit failure mode tablePlasma AIR Purifying OFFStart Instruction of troubleshooting· Flashing of Power lamp indicates abnormalities Troubleshooting check tableAIR PlasmaPurifying Trouble criterion of main parts When Power lamp flashes 3-time Indoor fan does not operate Troubleshooting flowCheck of indoor fan motor Check of remote controller and receiver P.C. board Indoor electronic control P.C.Board LED How to check mis-wiring and serial signal errorCheck of installation of the horizontal vane Plasma Deodorizing 0V? Safety Deviceplasma UnitAIR Purifying 0V? Continuously flash?Indoor unit and outdoor unit do not operate Check of auto front panelYes Electromagnetic noise enters into TV sets or radiosPower monitor receiver P.C. board Test point diagram and voltagePlasma power P.C. board Indoor electronic control P.C. boardRemoving the panel Photo Disassembly InstructionsRemoving the electrical box Operating Procedure PhotosRemoving the vertical vane motor unit Photo Removing the horizontal vane motor unit PhotoRemoving the indoor fan motor and the line flow Photo FanRemoving the plasma power P.C. board Photo Accessory and Remote Controller Parts ListIndoor Unit Electrical Parts and Functional Parts Safety PlasmaIndoor Unit Heat Exchanger Motor Receiver P.C Board HolderDiagram E02 Symbol Qty/unit Part name Wiring509 504Deodorizing Ceramic Filter Optional PartsPage Specifications subject to change without notice