Mitsubishi Electronics MSZ-FA35VA, MSZ-FA25VA Specification, When outdoor unit is MXZ type

Page 5

3

SPECIFICATION

Indoor model

Function

Power supply

 

Air flow(Super High)

 

K /h

Capacity Air flow(HighW/Med.W/LowW)

 

K /h

 

Power outlet

 

A

Electrical data

Running current 1

 

A

Power input 1

 

W

 

 

 

Auxiliary heater

 

A(kW)

 

Power factor 1

 

%

 

Fan motor current 1

 

A

Fan motor

Model

 

 

 

Dimensions WOHOD

 

mm

 

Weight

 

kg

 

Air direction

 

 

 

Sound level(Super High)

 

dB(A)

 

 

 

Sound level(HighW/Med.W/LowW)

 

dB(A)

Special remarks

Fan speed(Super High)

 

rpm

Fan speed regulator

 

rpm

 

Fan speed(HighW/Med.W/LowW)

 

 

Thermistor RT11(at25:)

 

k"

 

 

 

Thermistor RT12(at25:)

 

k"

 

Thermistor RT13(at25:)

 

k"

 

Remote controller model

 

 

MSZ-FA25VA - E1

MSZ-FA35VA - E1

Cooling

 

Heating

Cooling

 

Heating

 

 

Single phase

Single phase

230V,50Hz

230V,50Hz

594

 

612

594

 

612

474W/354W/252W

 

498W/384W/264W

474W/354W/258W

 

498W/384W/276W

 

10

 

10

0.25

0.25

 

33

 

33

 

 

 

57

 

57

0.25

0.25

RC0J40-EB

RC0J40-EB

780O298O198

780O298O198

 

10

 

10

 

4

 

4

 

42

 

42

36W/29W/21W

36W/29W/22W

1,220

 

1,250

1,220

 

1,250

1,010W/800W/610W

 

1,050W/850W/640W

1,010W/800W/630W

 

1,050W/850W/660W

 

4

 

4

 

10

 

10

 

10

 

10

 

10

 

10

KM05A

KM05A

 

 

 

 

 

 

When outdoor unit is MXZ type.

Indoor model

Function

Capacity Air flow(Super High)

Air flow(HighW/Med.W/LowW)

Special remarks

Sound level(Super High)

Sound level(HighW/Med.W/LowW)

 

 

Fan speed(Super High)

 

Fan speed(HighW/Med.W/LowW)

 

MSZ-FA25VA - E1

MSZ-FA35VA - E1

 

Cooling

 

Heating

Cooling

 

Heating

 

 

 

K /h

546

 

540

642

K /h

450W/348W/252W

 

420W/372W/264W

516W/390W/258W

 

522W/402W/276W

dB(A)

 

42

 

42

dB(A)

36W/29W/21W

36W/29W/22W

rpm

1,130

 

1,120

1,300

rpm

960W/790W/610W

 

910W/830W/640W

1,080W/860W/630W

 

1,090W/880W/660W

NOTE : Test conditions are based on ISO 5151

 

Cooling : Indoor

Dry-bulb temperature 27:Wet-bulb temperature 19:

Outdoor Dry-bulb temperature 35:Wet-bulb temperature

24:

Heating : Indoor

Dry-bulb temperature 20:Wet-bulb temperature 15:

Outdoor Dry-bulb temperature 7: Wet-bulb temperature

6:

Refrigerant piping length (one way): 5m

 

w Reference value

1 Measured under rated operating frequency.

Specifications and rating conditions of main electric parts

INDOOR UNIT

Item

Model

MSZ-FA25VA - E1 MSZ-FA35VA - E1

 

 

 

 

 

Fuse

(F11)

T3.15AL250V

 

 

 

Front panel driving motor

(MP)

NSEJ001DA1 12V DC 100" (at 25˚C)

i-see Sensor motor

(MT)

MP20Z 12V DC 300" (at 25˚C)

Horizontal vane motor

(MV1)

MSBPC20M16 12V DC 250" (at 25˚C)

Vertical vane motor

(MV2)

MSBPC20M11 12V DC 300" (at 25˚C)

Varistor

(NR11)

ERZV14D471

i-see Sensor

(RR)

A2TPMI334F0V50HSOBA060P5L1J4S 5V DC

 

 

 

Terminal block

(TB)

3P

 

 

 

 

 

5

Image 5
Contents MSZ-FA25VA E1 MSZ-FA35VA E1 ContentsFront panel opening/closing output gear Technical ChangesGeneralized stepping motor Part Names and Functions Wash reset switch Open Closed Receiving sectionIndoor Unit MSZ-FA25VA MSZ-FA35VA See control operationRemote Controller MSZ-FA25VA E1 MSZ-FA35VA E1 AccessoriesWhen outdoor unit is MXZ type SpecificationSpecifications and rating conditions of main electric parts MSZ-FA35VA E1 Noise Criteria CurvesMSZ-FA25VA E1 MSZ-FA25VA E1 MSZ-FA35VA E1 Outlines and DimensionsIndoor Unit Unit mmRefrigerant System Diagram Wiring DiagramMSZ-FA25VA E1 Indoor Unit MSZ-FA35VA E1 Indoor UnitHow to modify the remote controller P.C. board Service FunctionsRemote controller model KM05A OperationRemote controller Troubleshooting Remove InstallOutdoor Unit MXZ series Information for Multi System AIR ConditionerOFF Failure mode recall functionTo identify the error.Refer to 9-6.For G Plasma Deodorizing Indoor unit failure mode tablePlasma AIR Purifying OFFStart Instruction of troubleshooting· Flashing of Power lamp indicates abnormalities Troubleshooting check tablePurifying PlasmaAIR Trouble criterion of main parts Check of indoor fan motor Troubleshooting flowWhen Power lamp flashes 3-time Indoor fan does not operate Check of remote controller and receiver P.C. board Indoor electronic control P.C.Board LED How to check mis-wiring and serial signal errorCheck of installation of the horizontal vane Plasma Deodorizing 0V? Safety Deviceplasma UnitAIR Purifying 0V? Continuously flash?Indoor unit and outdoor unit do not operate Check of auto front panelYes Electromagnetic noise enters into TV sets or radiosPower monitor receiver P.C. board Test point diagram and voltagePlasma power P.C. board Indoor electronic control P.C. boardRemoving the panel Photo Disassembly InstructionsRemoving the electrical box Operating Procedure PhotosRemoving the vertical vane motor unit Photo Removing the horizontal vane motor unit PhotoRemoving the indoor fan motor and the line flow Photo FanRemoving the plasma power P.C. board Photo Accessory and Remote Controller Parts ListIndoor Unit Electrical Parts and Functional Parts Safety PlasmaIndoor Unit Heat Exchanger Motor Receiver P.C Board HolderDiagram E02 Symbol Qty/unit Part name Wiring509 504Deodorizing Ceramic Filter Optional PartsPage Specifications subject to change without notice