9-4. Troubleshooting check table
Lighted
· Flashing of POWER lamp indicates abnormalities.
Blinking
Not lighted
NOTE : Before taking measures, make sure that the symptom reappears for accurate troubleshooting. Self check table
No. | Abnormal | Operation indicator lamp | Symptom | Detection method | Check point | |
| point |
|
|
|
| |
|
| POWER lamp flashes. |
|
|
| |
| Outdoor unit | When the serial signal form the outdoor unit is | • Refer to | |||
1 | or serial |
| does not | |||
| not received for a maximum of 6 minutes. | |||||
| signal |
| operate. | error". | ||
|
|
|
|
| ||
| Outdoor |
|
| When it cannot properly read data in the | • Check the blinking pattern of | |
|
| Outdoor unit | the LED on the inverter P.C. | |||
2 | control | POWER lamp lights up | nonvolatile memory of the inverter P.C. board | board or the outdoor lectronic | ||
does not | or the outdoor electronic control P.C. board. | |||||
| system |
| control P.C. board. | |||
|
| operate. |
| |||
|
|
|
|
| ||
| Indoor coil | POWER lamp flashes. |
|
|
| |
| thermistor |
|
|
| ||
| Indoor unit | When the indoor coil or the room temperature | • Refer to | |||
|
| |||||
3 |
|
| and outdoor | thermistor is short or open circuit. | characteristics of indoor coil | |
Room |
| unit do not |
| thermistor, and the room | ||
| tempera- | operate. |
| temperature thermistor. | ||
| ture |
|
|
| ||
|
|
|
|
| ||
| thermistor |
|
|
|
| |
|
| POWER lamp flashes. | Indoor unit |
|
| |
|
| When the rotational frequency feedback | • Refer to | |||
| Indoor fan |
| and outdoor | |||
4 |
| signal is not emit during the indoor fan | ||||
motor |
| unit do not | indoor fan motor". | |||
|
| operation. | ||||
|
|
| operate. |
| ||
|
|
|
|
| ||
|
|
|
|
| ||
|
| POWER lamp flashes. | Indoor unit | When it consecutively occurs 3 times that the | • Refer to "Check of inverter/ | |
| Outdoor | |||||
| compressor". | |||||
5 | power |
| and outdoor | compressor stops for overcurrent protection or | Refer to service manual | |
| unit do not | |||||
| system |
| OB372 or OB377. | |||
|
| operate. | after | |||
|
| Check the stop valve. | ||||
|
|
|
| |||
|
|
|
|
| ||
|
| POWER lamp flashes. |
|
|
| |
|
| Indoor unit | When the outdoor thermistors short or open | • Refer to "Check of outdoor | ||
| Outdoor |
| and outdoor | thermistor". | ||
6 |
| unit do not | circuit during the compressor operation. | Refer to service manual | ||
thermistors |
| |||||
|
| operate. |
| OB372 or OB377. | ||
|
|
| ||||
|
|
|
|
| ||
|
| POWER lamp flashes. | Indoor unit |
| • Replace the inverter P.C. | |
| Outdoor | When it cannot properly read data in the | board or the outdoor | |||
| and outdoor | |||||
7 | control |
| nonvolatile memory of the inverter P.C. board | electronic control P.C. board. | ||
| unit do not | |||||
| system |
| or the outdoor electronic control P.C. board. | Refer to service manual | ||
|
| operate. | ||||
|
|
| OB372 or OB377. | |||
|
|
|
| |||
|
| POWER lamp flashes. | Indoor unit |
|
| |
| Other | An abnormality other than above mentioned is | • Confirm the abnormarity in | |||
8 |
| and outdoor | detail using the failure mode | |||
abnonmality |
| unit do not | deteced. | |||
|
|
| operate. |
| recall function. | |
|
|
|
| |||
|
|
|
|
|
NOTE : When the indoor unit has started operation and the above detection method has detected an abnormality (the first detection after the power ON), the indoor electronic control P.C. board turns OFF the indoor fan motor with OPERATION INDICATOR lamp flashing.