CONNECTING TO MAINS TERMINAL
WARNING: This cooker must be
| earthed. |
|
|
|
|
|
|
| Make connection as shown in Fig. 7 by |
|
|
| proceeding as follows:- |
|
|
| Preform wires to the appropriate shape to suit |
|
|
| fitting into the mains terminal block. |
|
|
| Strip inner insulation on wires using |
|
|
| wirestrippers. |
|
|
| Twist the bared wires using pliers. |
|
|
| Cut bared wires 10mm away from the end of |
| Fig.7 |
| the inner insulation. Where uninsulated Earth |
|
|
| wires are used ensure they are suitably |
|
|
| sheathed to leave 10mm bare wire to fit into |
|
|
| the terminal. |
|
|
| Clamp bare wires into the relevant terminal and |
|
|
| check they are held by tugging each one in turn. |
|
|
| Clamp the mains cable securely ensuring 5mm |
|
|
| of the outer insulation is inside the terminal |
|
|
| block and that the wires are not taut but not so |
|
|
| slack as to cause any fouling. See Fig. 7. |
|
|
| Place fuse/miniature circuit breaker in circuit |
|
|
| and switch on at mains. |
|
|
CONNECTING TO A HOB OR COOKER |
|
| |
POINT |
|
| |
| Either follow in general terms the instructions |
|
|
| for connecting to the terminal block or refer to |
|
|
| the hob suppliers installation instructions. |
|
|
|
|
|
|
| Feed the cable through the cabinet and |
|
|
| arrange to route the cable away from |
|
|
| the cooker which may become hot. |
|
|
|
|
|
|
CHECKING ELECTRICAL |
|
| |
CONNECTIONS |
|
| |
| Correct electrical connection can be confirmed |
|
|
| when switching on the appliance as the timer |
|
|
| will be flashing. |
|
|
NOTE: HOUSE CIRCUIT |
|
| |
Earth leakage and continuity tests must be carried |
|
| |
out before the cooker is connected to the mains |
|
| |
supply and |
|
|
47