Viking VIPR182R, VIPR102R, VIPR162R warranty Intended for Domestic Cooking only

Page 1

VIKING RANGE, LLC

Downdraft Ventilators

MODEL

WIDTH

BLOWER (purchase separately)

VIPR102

30"

VIDV500 Interior or VEDV900 Exterior

VIPR102R

30" w/ remote control

VIDV500 Interior or VEDV900 Exterior

VIPR162

36"

VIDV500 Interior or VEDV900 Exterior

VIPR162R

36" w/ remote control

VIDV500 Interior or VEDV900 Exterior

VIPR182

48"

VIDV500 Interior, VEDV900 Exterior or VEDV1200 Exterior

VIPR182R

48" w/ remote control

VIDV500 Interior, VEDV900 Exterior or VEDV1200 Exterior

WARNING - RANGETOPS ONLY: To reduce the risk of burns or ignition of clothing by reaching across burners, an "R" model downdraft (with remote control) MUST be used with a rangetop. The remote control MUST be mounted in the countertop - at least 4" from the burners. See "INSTALL COOKTOP" section on page 8.

READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

 

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty.

2.Beforeservicingorcleaningunit,switchpoweroffatservicepanel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installationworkandelectricalwiringmustbedonebyaqualified person(s)inaccordancewithallapplicablecodesandstandards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.To reduce the risk of fire, use only metal ductwork.

8.Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the burner should be 4 inches.

9.Loose-fitting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop.

10.Children should not be left alone or unattended in the area where this appliance is in use.

11.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when cooking flaming foods.

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa:

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immedi ately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN - You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher, and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

aBased on “Kitchen Firesafety Tips” published by NFPA.

CAUTION !

1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.Clean filters and grease-laden surfaces frequently.

4.Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be done by a qualified technician.

5.Please read specification label on product for further information and requirements.

6.DO NOT INSTALL WITH GRILL MODEL RANGETOPS. This will void the warranty.

7.Models VIPR102SS, VIPR162SS, and VIPR182SS (non- remote units): DO NOT INSTALL WITH RANGETOPS. This will void the warranty.

INSTALLER:

Save this manual for Electrical Inspector and

Homeowner to use.

HOMEOWNER:

1Use and Care Information on Page 11.

Image 1
Contents To Reduce the Risk of a Range TOP Grease Fire Intended for Domestic Cooking onlyPlanning Electrical SpecificationsTake Measurements VAC 60 Hz 4.0 aSide View Downdraft With VIDV500 Interior Blower Plan the DuctworkSide View Downdraft With Round Elbow Plan the Cabinet Cutouts Prepare the Downdraft Plan the WiringImportant Location of Electrical Outlet Outlet cannot be located on the back wall of cabinetNuts Motor RoundAdditional Cutout for Vecu Cooktops & Vgrt Rangetops VGSU102 & VGSU162 CUT Countertop OpeningCutout for VEC Cooktops VGC Cooktops Mount the Unit Install DuctworkBefore Cutting Hole Cabinet for Ductwork Installation of Remote Control Switch Backside Remote Switch Template Install Cooktop Install Electrical WiringModel Downdraft USE and Care OperationProfessional Series BUILT-IN Rear Downdraft Warranty Ventilateurs encastrés Destiné À LA Cuisine Domestique Seulement AvertissementPrise DES Mesures PréparationSpécifications ÉlectriquesPréparation DES Conduits Prise DES Mesures SuiteSortie À Gauche Préparation DU Découpage DE L’ARMOIRESortie À Droite Sortie Vers LE BASPréparation DE LA Hotte Préparation DU CâblageImportant Position DE LA Prise Électrique Écrous Tion Ronde DEDécoupe pour VEC Surface de cuisson VGC Surface de cuisson Découpage DU ComptoirAvant DE Découper L’AR Moire Pour LES Conduits Installation DE L’UNITÉTuyaux de nuisent pas Câblage Électrique Installation DE LA Surface DE CuissonCuisinière Hotte Modèle R Télécom Mande ComptoirBordtopduedgecomptoir Installation DE LA TélécommandeArrière DU Gabarit DE LA Télécommande Commande DES Modèles VIPR102SS VIPR162SS VIPR182SS Télécommande DES Modèles VIPR102RSS VIPR162RSS VIPR182RSSFonctionnement Utilisation ET EntretienGarantie DES Hottes Encastrées DE Série Professionnelle Ventiladores de tiro descendente PrecauciónTome Medidas PlaneaciónEspecificaciones Eléctricas VCA 60 Hz 4.0 aPara conectarse al ventilador exterior VEDV900 o VEDV1200 Planee LOS Conductos½ pulg.14 cm Planee LOS Cortes DEL GabinetePrepare EL Tiro Descendente Planee EL Cableado EléctricoVentiladores de tiro descendente Recorte para VEC Estufa VGC Estufa Haga LA Abertura DE LA Superficie DEL GabineteInstale EL Sistema DE Conductos Monte LA UnidadBorde Superior Instalación DEL Interruptor DEL Control RemotoParte Posterior DE LA Plantilla DEL Conmutador Remoto Instale LA Estufa Instale EL Cableado EléctricoUSO Y Cuidado FuncionamientoViking RANGE, LLC Garantía Limitada DE Cinco AñosF20073C SP

VIPR182R, VIPR182, VIPR102, VIPR102R, VIPR162 specifications

The Viking VIPR series encompasses a range of versatile and robust vacuum pumps designed for various applications, chiefly in the manufacturing and industrial sectors. Notably, models such as VIPR162R, VIPR162, VIPR102R, VIPR102, and VIPR182 stand out for their performance and efficiency.

The VIPR162R and VIPR162 share many core features. Both systems are engineered to deliver high pumping speeds, making them suitable for a variety of vacuum applications. They boast an advanced oil circulation system, which not only ensures optimal lubrication but also extends the longevity of the pump. The design is compact, allowing for easy installation and integration into existing systems, without occupying excessive space.

Moving on to the VIPR102R and VIPR102 models, these units are tailored for smaller vacuum requirements while maintaining robust performance. The intuitive control interface allows for easy operation. These pumps come equipped with a maintenance-free design that reduces downtime, a key advantage in high-demand environments. Similarly, they feature an energy-efficient motor that lowers operational costs while maintaining power and efficiency.

The VIPR182 model takes performance to another level with its increased pumping capacity. This vacuum pump is designed for heavy-duty industrial applications, significantly enhancing productivity due to its ability to handle high volumes. Like its peers, it showcases the same advanced oil circulation technology and durable construction, ensuring reliability in even the most demanding conditions.

All models in the VIPR series emphasize energy efficiency and environmental sustainability, echoing current industry trends toward greener technologies. They are equipped with noise-reduction components, contributing to a quieter working environment which is essential in many industrial applications.

Reliability is another hallmark of the Viking VIPR series. With high-quality materials and stringent manufacturing standards, these pumps are built to withstand the rigors of daily usage. Moreover, they typically feature advanced monitoring systems that provide real-time feedback on performance, allowing for prompt maintenance and minimal disruptions.

In conclusion, the Viking VIPR162R, VIPR162, VIPR102R, VIPR102, and VIPR182 models offer a compelling combination of performance, efficiency, and reliability. With their advanced technologies and robust design, they fit seamlessly into industrial processes, making them invaluable assets for businesses seeking to enhance productivity while managing costs effectively.