4.Using the final measurement from Step 3, measure from the floor up and mark a horizontal line on the wall where a wall stud is located.
A
B
D
C
A. Horizontal line marked from Step 4.
B. Wall stud
C. Mounting screws
D.
5.Position top of
Make Electrical Connection - U.S.A. Only
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground range.
Failure to follow these instructions can result in death, fire, or electrical shock.
This range must be connected to a grounded, metallic permanent wiring system or a ground connector should be connected to the ground terminal or wire lead on the range.
This range is manufactured with a cabinet connected, green or bare ground wire. Connect the range cable to the junction box through the UL listed or CSA approved conduit connector.
Electrical Connection Options
If your home has: | And you will be | Go to Section: |
| connecting to: |
|
A fused | ||
| disconnect or | Power Supply |
| circuit breaker |
|
5" | box |
|
|
| |
(12.7 cm) |
|
|
A fused | ||
| disconnect or | Power Supply |
| circuit breaker |
|
3¹⁄₂" | box |
|
(8.9 cm) |
|
|
4-Wire Cable from Power Supply
IMPORTANT: Use the
A
B
|
|
| E |
|
|
| F |
|
|
| G |
|
|
| |
C | H | ||
D | I | ||
A. Cable from power supply | F. White wires | ||
B. Red wires | G. UL listed wire nuts | ||
C. Green (or bare) ground wires | H. Black wires | ||
D. | I. UL listed or CSA approved | ||
E. Junction box | conduit connector |
1.Disconnect power.
2.Remove junction box cover if present.
3.Connect the
4.Tighten screws on conduit connector if present.
5.Connect the two black wires together using the UL listed wire nuts.
6.Connect the two white wires together using the UL listed wire nuts.
7.Connect the green or bare ground wire from the range cable to the green or bare grounded wire (in the junction box) using the UL listed wire nuts.
8.Install junction box cover.
9.Reconnect power.
9