4.0Hardware Layout Example
DS7416i
Communications
Module
R |
B |
G |
Y |
+ – + | 2 3 | 4 5 | 6 7 | 8 | + – + | 2 3 | 4 5 | 6 7 | 8 |
POWER BUS |
|
|
|
| POWER BUS |
|
|
|
|
Keypads #11 - #15 must be connected to |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
the Options Bus. Keypads #1 - #10 must |
|
|
| DS7430 |
|
|
|
|
|
|
|
| ||||||||||||
be connected to the Keypad Bus. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
Armed |
|
|
| Arme d |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
St atus |
|
|
| Stat us |
|
|
|
|
|
|
|
| + | – | + | – |
|
|
|
|
|
|
|
|
Power |
|
|
| Powe r |
|
|
|
|
|
|
|
| + – + | 2 | 3 4 5 6 7 8 | + – + | 2 3 | 4 5 6 7 | 8 | |||||
Fire |
|
|
| Fire |
|
|
|
|
|
|
|
| Power Bus |
| ||||||||||
|
|
| On |
|
|
|
|
| On |
|
|
|
| POWER BUS |
|
|
| POWER BUS |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
1 | 2 | 3 | Off | 1 |
| 2 | 3 |
| Off |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | 5 | 6 | Per imete r | 4 |
| 5 | 6 |
| Per imete r |
|
|
|
|
|
|
|
|
|
| DS7432 |
|
|
| |
O nly |
|
| O nly |
|
|
|
|
|
| DS7400Xi |
|
|
|
|
|
| ||||||||
* | 0 | # | Byp ass | * |
| 0 | # |
| Byp ass |
|
|
|
|
|
|
|
|
|
|
|
| |||
7 | 8 | 9 | No | 7 |
| 8 | 9 |
| No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Entry |
|
| Entr y |
|
|
|
|
|
|
|
|
| Remote Modules |
|
|
| ||||||||
|
|
| Syste m |
|
|
|
|
| Sys tem |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Reset |
|
|
|
|
| Reset |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fire |
|
| Pow er | Bell Sile nce d | 1 2 3 | 4 5 6 | 7 | 8 |
| 1 | R |
|
|
|
|
|
|
|
| Dry contact inputs 47kΩ | ||||
|
|
| 4 | Y |
|
|
|
|
|
|
|
|
|
|
|
| EOL | |||||||
Armed |
|
|
|
|
|
|
|
|
| 2 | B |
| Option |
|
|
|
|
|
|
|
|
|
|
|
St atus |
|
| Armed | Pe ri met er |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Power |
|
| Sta tus | Superv isory |
|
|
|
|
| 3 | G |
| Bus |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fire | Trouble | 9 10 11 12 13 14 | 15 16 |
|
| + |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| On |
| TEST WEEKLY |
|
| On | 5 | – | Battery |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| 6 | – |
|
|
|
|
|
|
|
|
|
|
|
| ||
1 | 2 | 3 | Off |
|
|
|
|
|
| 7 | + |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 1 | 2 | 3 |
|
| Off | 8 | – |
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | 5 | 6 | Per imete r |
|
| 9 | + |
| Auxiliary |
|
|
|
|
|
|
|
|
|
|
| ||||
O nly |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| 4 | 5 | 6 |
|
| Per imete r | 10 | – |
| Output |
|
|
|
|
|
|
|
|
|
|
|
7 | 8 | 9 | No |
|
| O nly |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Entry |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 7 | 8 | 9 | No | – + + + – – R R T T R R T T R R T T |
* | 0 | # | Byp ass | Ent ry |
|
|
|
| * |
| 0 | # |
| Byp as s | 1 12 1 3 1 4 15 16 17 18 1 9 20 21 22 23 24 25 2 6 27 28 |
|
|
|
|
|
|
|
|
|
|
|
| Syste m |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| Reset |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Syst em |
|
|
|
|
|
|
|
|
| + |
|
|
|
|
|
|
|
|
| Re set |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DS7420i Dual Phone | DS7488 Octal | 1 | 2 | 3 | 4 | 5 | 1 | 2 | 3 |
Armed |
|
|
|
|
|
|
|
|
| 2 G 1 - | + | NO C NC | |||||||
St atus |
|
| Armed | Pe ri met er | 9 | 10 11 12 13 | 14 | 15 16 | Line/Bell Supervision | Relay Board |
|
|
| BUS |
|
|
| ||
Fire |
|
| Fire | Trouble |
|
|
|
|
|
|
|
| |||||||
Power |
|
| Sta tus | Superv isory | 1 | 2 3 4 5 | 6 | 7 | 8 |
|
|
|
|
|
|
|
|
|
|
|
|
| Pow er | Bell Sile nce d |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| On |
|
| TEST WEEKLY |
| On | Module |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
1 | 2 | 3 | Off | 1 |
| 2 | 3 |
| Off |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
4 | 5 | 6 | PerOimetenly r | 4 |
| 5 | 6 |
| Per imete r |
|
|
|
|
|
|
|
|
|
|
|
|
| O nly |
|
|
|
|
|
|
|
|
|
| ||||||
7 | 8 | 9 | No | 7 |
| 8 | 9 |
| No |
|
| DS7450/52 Series Contacts, DS7460 Input Modules, | |||||||
Entry |
|
| Ent ry |
|
| ||||||||||||||
* | 0 | # | Byp ass | * |
| 0 | # |
| Byp as s |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Syste m |
|
|
|
|
| Syst em |
|
| DS7465 Input/Output Modules, MX540, MX775, | |||||||
|
|
| Reset |
|
|
|
|
| Re set |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| Battery | Battery | ||||||||
|
|
|
|
|
|
|
|
|
| MX794, MX835, MX934, MX938, and MX950 motion | |||||||||
Fire |
|
| Fire | Trouble | 9 | 10 11 12 13 | 14 | 15 16 |
|
| |||||||||
Armed |
|
| Armed | Pe ri met er |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
St atus |
|
| Sta tus | Superv isory | 1 2 3 4 5 | 6 | 7 | 8 |
|
|
|
|
|
|
|
|
|
| |
Power |
|
| Pow er | Bell Sile nce d |
|
|
|
|
|
|
|
|
|
| |||||
|
|
| On |
|
| TEST WEEKLY |
| On |
|
| detectors and MX280 Series Smoke Detectors | ||||||||
|
|
|
|
|
|
|
|
|
| ||||||||||
1 | 2 | 3 | Off | 1 |
| 2 | 3 |
| Off |
|
| ||||||||
4 | 5 | 6 | Per imete r | 4 |
| 5 | 6 |
| imete r |
|
|
|
|
|
|
|
|
|
|
O nly |
|
| PerO nly |
|
|
|
|
|
|
|
|
|
| ||||||
7 | 8 | 9 | No | 7 |
| 8 | 9 |
| No |
|
|
|
|
|
|
|
|
|
|
Entry |
|
| Ent ry |
|
|
|
|
|
|
|
|
|
| ||||||
* | 0 | # | Byp ass | * |
| 0 | # |
| Byp as s |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| Syste m |
|
|
|
|
| Syst em | Note: Ensure at least 1/4" separation |
|
|
|
|
|
|
|
| |
|
|
| Reset |
|
|
|
|
| Re set |
|
|
|
|
|
|
|
| ||
DS7447/DS7447E and DS7445/DS7445i |
|
|
|
|
|
|
|
| |||||||||||
between battery wires and all |
|
|
|
|
|
|
|
| |||||||||||
|
|
| Keypads |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| other cabling. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RF3222 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Wireless Receivers |
|
|
|
|
|
|
|
|
|
| Wireless Sensors |
|
|
|
|
|
|
|
|
•Up to 15 keypads may be used. Keypads #1 - #10 connect to the Keypad Bus and keypads #11 - #15 connect to the Option Bus. One keypad must be designated as keypad #1 and connected to the Keypad Bus. See the DS7447/DS7447E, DS7445/DS7445i, and DS7448 Installation Instructions for further details.
•A DS7420i (Dual Phone Line/Bell Supervision Module) may be connected to the Control Panel, and placed within the enclosure. Connect to the Options Bus of the control panel. See the DS7420i Installation Instructions for further details.
•Up to 2 DS7488s (Octal Relay Modules) may be connected to the Control Panel, and placed within the enclosure. Connect to the Options Bus of the Control Panel. This provides an additional 8 Form “C” relay outputs for the Control Panel. See the DS7488 Installation Instructions for further details.
•A DS7430 or a DS7436 (Multiplex Expansion Module) may be connected to the control panel via the expansion port. This will allow for the connection of additional zones via the Options Bus. See the DS7430 or DS7436 Installation Instructions for further details.
•Up to 30 DS7432s
•Up to 2 RF3222
•A DS7416i Advanced Radio Communications Module may be connected to the Control Panel via the Options Bus. This allows for connection to a radio network.
•Up to 248 zones are available for the connection of Single, Multiple, Input/Output, and Multiplex devices. Up to 112 wireless zones
DS7400Xi ( 4+) Reference Guide | Copyright © 2007 Bosch Security Systems, Inc. | P/N: |