Bosch Appliances DS7447 DS7430, DS7400Xi, Note: Ensure at least 1/4 separation, other cabling

Models: DS7445I DS7447 DS7400XI DS7447E

1 100
Download 100 pages 4.36 Kb
Page 11
Image 11
Keypads #11 - #15 must be connected to

4.0Hardware Layout Example

DS7416i

Communications

Module

R

B

G

Y

+ – + –1

2 3

4 5

6 7

8

+ – + –1

2 3

4 5

6 7

8

POWER BUS

 

 

 

 

POWER BUS

 

 

 

 

Keypads #11 - #15 must be connected to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the Options Bus. Keypads #1 - #10 must

 

 

 

DS7430

 

 

 

 

 

 

 

 

be connected to the Keypad Bus.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Armed

 

 

 

Arme d

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

St atus

 

 

 

Stat us

 

 

 

 

 

 

 

 

+

+

 

 

 

 

 

 

 

 

Power

 

 

 

Powe r

 

 

 

 

 

 

 

 

+ – +

–1

2

3 4 5 6 7 8

+ – + –1

2 3

4 5 6 7

8

Fire

 

 

 

Fire

 

 

 

 

 

 

 

 

Power Bus

 

 

 

 

On

 

 

 

 

 

On

 

 

 

 

POWER BUS

 

 

 

POWER BUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

Off

1

 

2

3

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

6

Per imete r

4

 

5

6

 

Per imete r

 

 

 

 

 

 

 

 

 

 

DS7432 8-Input

 

 

 

O nly

 

 

O nly

 

 

 

 

 

 

DS7400Xi

 

 

 

 

 

 

*

0

#

Byp ass

*

 

0

#

 

Byp ass

 

 

 

 

 

 

 

 

 

 

 

 

7

8

9

No

7

 

8

9

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entry

 

 

Entr y

 

 

 

 

 

 

 

 

 

Remote Modules

 

 

 

 

 

 

Syste m

 

 

 

 

 

Sys tem

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset

 

 

 

 

 

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fire

 

 

Pow er

Bell Sile nce d

1 2 3

4 5 6

7

8

 

1

R

 

 

 

 

 

 

 

 

Dry contact inputs 47kΩ

 

 

 

4

Y

 

 

 

 

 

 

 

 

 

 

 

 

EOL

Armed

 

 

 

 

 

 

 

 

 

2

B

 

Option

 

 

 

 

 

 

 

 

 

 

 

St atus

 

 

Armed

Pe ri met er

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

Sta tus

Superv isory

 

 

 

 

 

3

G

 

Bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fire

Trouble

9 10 11 12 13 14

15 16

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

 

TEST WEEKLY

 

 

On

5

Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

Off

 

 

 

 

 

 

7

+

–Bell Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

 

Off

8

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

6

Per imete r

 

 

9

+

 

Auxiliary

 

 

 

 

 

 

 

 

 

 

 

O nly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

6

 

 

Per imete r

10

 

Output

 

 

 

 

 

 

 

 

 

 

 

7

8

9

No

 

 

O nly

 

 

 

 

 

 

 

 

 

 

 

 

 

Entry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

8

9

No

– + + + – – R R T T R R T T R R T T

*

0

#

Byp ass

Ent ry

 

 

 

 

*

 

0

#

 

Byp as s

1 12 1 3 1 4 15 16 17 18 1 9 20 21 22 23 24 25 2 6 27 28

 

 

 

 

 

 

 

 

 

 

 

 

Syste m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Syst em

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

Re set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DS7420i Dual Phone

DS7488 Octal

1

2

3

4

5

1

2

3

Armed

 

 

 

 

 

 

 

 

 

2 G 1 -

+

NO C NC

St atus

 

 

Armed

Pe ri met er

9

10 11 12 13

14

15 16

Line/Bell Supervision

Relay Board

 

 

 

BUS

 

 

 

Fire

 

 

Fire

Trouble

 

 

 

 

 

 

 

 

Power

 

 

Sta tus

Superv isory

1

2 3 4 5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

Pow er

Bell Sile nce d

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

 

 

TEST WEEKLY

 

On

Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

Off

1

 

2

3

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

6

PerOimetenly r

4

 

5

6

 

Per imete r

 

 

 

 

 

 

 

 

 

 

 

 

 

O nly

 

 

 

 

 

 

 

 

 

 

7

8

9

No

7

 

8

9

 

No

 

 

DS7450/52 Series Contacts, DS7460 Input Modules,

Entry

 

 

Ent ry

 

 

*

0

#

Byp ass

*

 

0

#

 

Byp as s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Syste m

 

 

 

 

 

Syst em

 

 

DS7465 Input/Output Modules, MX540, MX775,

 

 

 

Reset

 

 

 

 

 

Re set

 

 

 

 

 

 

 

 

 

 

 

 

Battery

Battery

 

 

 

 

 

 

 

 

 

 

MX794, MX835, MX934, MX938, and MX950 motion

Fire

 

 

Fire

Trouble

9

10 11 12 13

14

15 16

 

 

Armed

 

 

Armed

Pe ri met er

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

St atus

 

 

Sta tus

Superv isory

1 2 3 4 5

6

7

8

 

 

 

 

 

 

 

 

 

 

Power

 

 

Pow er

Bell Sile nce d

 

 

 

 

 

 

 

 

 

 

 

 

 

On

 

 

TEST WEEKLY

 

On

 

 

detectors and MX280 Series Smoke Detectors

 

 

 

 

 

 

 

 

 

 

1

2

3

Off

1

 

2

3

 

Off

 

 

4

5

6

Per imete r

4

 

5

6

 

imete r

 

 

 

 

 

 

 

 

 

 

O nly

 

 

PerO nly

 

 

 

 

 

 

 

 

 

 

7

8

9

No

7

 

8

9

 

No

 

 

 

 

 

 

 

 

 

 

Entry

 

 

Ent ry

 

 

 

 

 

 

 

 

 

 

*

0

#

Byp ass

*

 

0

#

 

Byp as s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Syste m

 

 

 

 

 

Syst em

Note: Ensure at least 1/4" separation

 

 

 

 

 

 

 

 

 

 

 

Reset

 

 

 

 

 

Re set

 

 

 

 

 

 

 

 

DS7447/DS7447E and DS7445/DS7445i

 

 

 

 

 

 

 

 

between battery wires and all

 

 

 

 

 

 

 

 

 

 

 

Keypads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

other cabling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF3222 120-Zone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wireless Receivers

 

 

 

 

 

 

 

 

 

 

Wireless Sensors

 

 

 

 

 

 

 

 

Up to 15 keypads may be used. Keypads #1 - #10 connect to the Keypad Bus and keypads #11 - #15 connect to the Option Bus. One keypad must be designated as keypad #1 and connected to the Keypad Bus. See the DS7447/DS7447E, DS7445/DS7445i, and DS7448 Installation Instructions for further details.

A DS7420i (Dual Phone Line/Bell Supervision Module) may be connected to the Control Panel, and placed within the enclosure. Connect to the Options Bus of the control panel. See the DS7420i Installation Instructions for further details.

Up to 2 DS7488s (Octal Relay Modules) may be connected to the Control Panel, and placed within the enclosure. Connect to the Options Bus of the Control Panel. This provides an additional 8 Form “C” relay outputs for the Control Panel. See the DS7488 Installation Instructions for further details.

A DS7430 or a DS7436 (Multiplex Expansion Module) may be connected to the control panel via the expansion port. This will allow for the connection of additional zones via the Options Bus. See the DS7430 or DS7436 Installation Instructions for further details.

Up to 30 DS7432s (8-Input Remote Modules) may be connected to the DS7430 or DS7436. Connect to the Power and Bus Terminals of the Multiplex Expansion Module. This allows for a means of addressing up to 240 input loops of conventional contacts to the Control Panel. See the DS7432 Installation Instructions for further details.

Up to 2 RF3222 (120-Zone Wireless Receivers) may be connected to the DS7430 or DS7436. Connect to the Power and Bus terminals of the Multiplex Expansion Module. This allows for the monitoring of wireless detectors.

A DS7416i Advanced Radio Communications Module may be connected to the Control Panel via the Options Bus. This allows for connection to a radio network.

Up to 248 zones are available for the connection of Single, Multiple, Input/Output, and Multiplex devices. Up to 112 wireless zones (137-248) are also available.

DS7400Xi ( 4+) Reference Guide

Copyright © 2007 Bosch Security Systems, Inc.

P/N: F01U035325-01 Page 11

Page 11
Image 11
Bosch Appliances DS7447 DS7430, DS7400Xi, Note: Ensure at least 1/4 separation, between battery wires and all, Battery