Options

Step 2: Assigning a Zone Function to the Zone

In this step, a Zone function is assigned to the Zone.

10.3Zone Programming: Program Addresses (0031-0278)

In Zone Programming, each zone is defined according to its input (single or multiple zone input, or a DS7465) and its Zone Function (1-30) or Output Function (1-24). The DS7465’s relay is the only device that will follow the output functions; its input loop will follow a zone function. All single and multiple zone inputs will follow a zone function. See section 6.3 for further details.

Data Digit

1

2

 

 

 

Options

 

Zone

 

 

 

 

 

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disable a zone

 

00

The DS7465 occupies two zones. The odd numbered

 

 

 

 

 

zone of the zone pair is the input zone. The even

Enter a Zone Function Value

 

01-30

numbered zone of the zone pair is the output relay.

 

 

 

 

 

 

The output follows an output function.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

 

 

 

 

 

 

 

 

Function

 

 

 

Zone Number

Address

 

Default

 

 

1

 

0031

 

01

 

 

2

 

0032

 

02

 

 

3

 

0033

 

03

 

 

4

 

0034

 

04

 

 

5

 

0035

 

05

 

 

6

 

0036

 

06

 

 

7

 

0037

 

07

 

 

8

 

0038

 

08

 

 

9-248

 

0039-0278

 

00

 

 

 

 

 

 

 

 

 

 

 

Hint: Address = Zone Number + 30

Page 36 P/N: F01U035325-01

Copyright © 2007 Bosch Security Systems, Inc.

DS7400Xi (4+) Reference Guide