10.27 Report Programming: Program Addresses (3207-3419)

10.27 Report Programming: Program Addresses (3207-3419)

To send the User number along with open, close, or partial close reports: place an ‘F’ (*5) in the extended digit.

To disable a report (meaning that nothing will be sent), place a ‘0’ in the reporting digit.

When using SIA or Contact ID format, place a ‘1’ in the reporting digit of each report you wish to enable. It is not necessary to program the extended digit.

For suggested values for 4/2, BFSK and Pager format, see section 12.1-12.3. For SIA and Contact ID, the values sent are listed in sections 13.1 and 13.2. For other formats, consult your central station.

HEX values: Some Data Digit values are higher than 9. These values are programmed by pressing the [*] key followed by another number. These values will display as HEX characters when entered. The HEX character values are as follows:

*0 = A *1 = B *2 = C *3 = D *4 = E *5 = F

See Glossary (section 6.13) for further details.