6.0Glossary
6.1General Control Programming
•Normal Arming - [PIN] + [On]: If programmed, arms the entire system while allowing entry delays for entry/exit zones.
•Perimeter Instant Arming - [PIN] + [No Entry] [Perimeter Only]: If programmed, arms only the perimeter of the system and does not allow entry delays for entry/exit zones.
•Perimeter Arming - [PIN] + [Perimeter Only]: If programmed, arms only the perimeter of the system while allowing entry delays for entry/exit zones.
•Custom Arming - [PIN] + [#] [4]: If programmed, allows custom arming of the system and bypasses the zone functions specified in data addresses
•Maximum Security Arming - [PIN] + [No Entry] [On]: If programmed, arms the entire system and does not allow an entry delay for entry/exit zones.
•General Authority by Partition
A general (level 2) authority can be programmed to have arm- only authority; arm and bypass authority; arm and disarm authority; or arm, disarm, and bypass authority by partition. This is done at addresses
-
-This level can still be used to arm, disarm, and bypass zones in the other partitions that it has access to.
•Closing
-If a closing report is not programmed, the control will test for a dial tone when the system is armed. If the test passes, the system will arm normally. If the test fails, the system will arm, but will indicate a trouble condition.
-The DS7447/DS7447E keypad will display “Communication Err” after [#] [8] [7] is entered.
•Siren on Comm. Fail for Silent Zone: If programmed, a silent zone will sound the alarm outputs if the zone is in an alarm condition and the system fails to communicate with the central station.
•Restore when Sounders Silence: If programmed, a zone sends a restoral report and is ready to activate again only after the burglary bell
-The zone can alarm multiple times per armed period.
•Restore when Zone Restores: If programmed, a zone sends a restoral report and is ready to activate again as soon as it physically restores.
-This zone can alarm multiple times per armed period.
•Restore when System Disarms: If programmed, a zone sends a restoral report when the system is disarmed.
-It can only alarm once per armed period.
•Allow Swinger Shunts: If programmed, a zone can only alarm or trouble up to three times per armed period. After the third alarm or trouble, the zone will be bypassed and a bypass report will be sent.
NOTE: Swinger Shunts are not allowed on UL Certificated Installations.
6.2Zone Function Programming
•Zone Function
A Zone Function is the description of how a particular zone will behave (e.g. steady alarm output, bypassing allowed, alarm on short, trouble on open, perimeter instant).
-There are many possible zone functions. Up to 30 different zone functions are allowed per control.
-Zone functions may be custom made as needed.
-Each zone must be programmed as a specific zone function. Any number and combination of zones may be programmed as particular zone functions.
-Program zone functions at addresses
•Invisible Alarms: This is a zone programmed not to have an alarm output or an alarm display at any keypad when activated. An alarm signal will be sent, but the DS7447/DS7447E keypad display will read “Not Ready” while this zone is violated.
-Invisible Alarm zones are recommended for holdup alarms.
•Silent Alarms: This is a zone programmed to activate the visual display at the keypad, but not audible signals.
-If this zone is also an entry zone, an entry tone will sound when this zone is activated.
•Bypassing Allowed: This is a zone programmed to allow bypassing (shunting). This is done using the bypass command or the
•Alarm on Short: This is a zone programmed to activate an alarm when its loop is shorted.
•Alarm on Open: This is a zone programmed to activate an alarm when its loop is opened.
•Trouble on Open: This is a zone programmed to activate a trouble when its loop is opened and the system is disarmed.
-If the system is armed, this zone will activate an alarm if shorted or opened.
-For
•Trouble on Short: This is a zone programmed to activate a trouble when its loop is shorted and the system is disarmed.
-If the system is armed, this zone will activate an alarm if shorted or opened.
-For
•Interior Delayed: This is a zone programmed to be ignored during the entry/exit delay period. If it is violated when the system is armed, it will activate a delay for the programmed entry delay time. The keypad
•Perimeter Instant: This is a zone programmed to activate an alarm even during the entry/exit delay period.
•
•Entry/Exit Delay #1: This is a zone programmed to be ignored during the entry/exit delay period.
-If it is violated while the system is armed, it will activate a delay for the amount of time programmed for entry delay time #1 (address 4028). The keypad
-If the system is not disarmed during the entry period, this zone will activate an alarm.