Data Digit

10.24 DS7412 RS232 Interface Control Programming: Program Address (4019)

DS7412 RS232 Interface Control Programming allows you to enable or disable the DS7412 and to select which history events are sent to the printer as they occur. Selecting “No Events” will cause the history to be printed only on command.

To print the History Buffer starting from the most recent event, enter the Master Code followed by [#] [0] [8]. To stop printing, enter Master Code [#] [0] [8] again.

10.25 DS7412 RS232 Interface Configuration Programming: Program Address (4020)

DS7412 RS232 Interface Configuration Programming allows you to configure the DS7412 for your printer. Most printers will operate using the default values for the DS7412. Some printers may operate more efficiently using optional program values.

Consult the operating guide provided with your printer to be sure that its configuration matches the one programmed here.

NOTE: If using the WDSRP Direct Connection option for programming, Address 4019 must be set for 1 0. Address 4020 must be set for 2 5.

10.26 RS232 Carriage Return/Line Feed Control: Program Address (4027)

The RS232 Carriage Return/Line Feed (CR/LF) Control allows you to choose between sending carriage returns/line feeds or spac- es to the DS7412 module. This is only used when Program Address 4019 Data Digit #2 is programmed with the numbers 1 through 7.

Data Digit

Select Option

Send CR/LF

Send Spaces

DD

0Select OptionManual background

1

12

Manual backgroundManual background 0

Page 52 P/N: F01U035325-01