NOTE: User Number 001 can not be disabled in this manner.
7.6The Master Keypad
7.6.1 General Information
Your system may include a Master keypad. A Master keypad is a DS7447/DS7447E keypad programmed to give a user access to all the partitions the user has access to, not just the partition in which the Master keypad is located. This is different from a Standard keypad in that Standard keypads only give access to the single partition in which they are located. Commands entered at the Master keypad will affect all the partitions to which the user has access. If this is not desirable, the Master keypad can also be used to control each partition individually; this is called Single Partition Mode. Single Partition Mode allows a user to control any or all of the partitions the user has access to on an individual (one-
NOTE: In order to use the Master keypad, your PIN must be assigned to the partition in which the Master keypad is located.
7.6.2Master Keypad Displays
Master keypad displays will differ slightly from Standard keypads. The Master keypad display will scroll the Status of each partition, followed by the partition number. For example, if all partitions are armed, the Master keypad will scroll through the following displays:
Armed Armed Armed Armed Armed Armed Armed Armed area 1 area 2 area 3 area 4 area 5 area 6 area 7 area 8
If only partitions 1, 2, 3, 4, 6, and 8 are armed, the Master keypad will scroll through the following displays:
Armed | Armed | Armed | Armed | Ready to Arm | Armed | Ready to Arm | Armed |
area 1 | area 2 | area 3 | area 4 | area 5 | area 6 | area 7 | area 8 |
Displays for partitions that are Not Ready will display in the same manner.
The chart at the bottom of this page will help you understand what each LED function of the Master keypad represents.
7.6.3 Single Partition Mode
Single Partition Mode is used to control partitions on a “one at a time/one by one” basis from the Master keypad.
To enter the Single Partition Mode, enter your [PIN], then press the
[#]key twice. This will call up the first partition you have access to. Enter the command sequence you wish for this partition. You do not need to use your PIN again. To move on to the next partition you have access to, press the [#] key twice.
To exit the Single Partition Mode, hold the [*] key down for 2 seconds. The system will also automatically drop out of Single Partition Mode after 40 seconds without a keypad entry.
Example of accessing Single Partition Mode
• Enter your [PIN], followed by the [#] key twice: [1] [2] [3] [4] [#] [#].
•The first partition you have access to will be displayed: “Ready to Arm. Cafeteria.”
•Complete the command sequence (in this case arming) you wish for this partition: [#] [On].
•Move to the next partition you have access to by pressing the [#] key twice: [#] [#].
•The next partition you have access to will be displayed: “Ready to Arm. Office.”
•Complete the command sequence you wish for this partition.
•After you have completed all the command sequences for the partitions you have access to, exit Single Partition Mode by pressing the [*] key for two seconds.
7.6.4 Arming from the Master Keypad
To arm all the Partitions to which you have access:
•[PIN] + any Arming Command Sequence. This will arm all the partitions to which you have access even if they are already armed.
To arm only some of the Partitions to which you have access:
•[PIN] + [#] + [#]. This puts you into Single Partition Mode.
•The first partition to which you have access is displayed: “Ready to Arm. Cafeteria.”
•Enter the Arming Command Sequence you want for this parti- tion.
•[#] + [#] opens the next partition to which you have access.
•The next partition to which you have access is displayed: “Ready to Arm. Office.”
•Enter the Arming Command Sequence you want for this parti- tion.
•After arming any or all partitions to which you have access, you may exit Single Partition Mode by holding the [*] key for at least two seconds. The system will also drop out of Single Partition Mode after 40 seconds without a keypad entry.
7.6.5 Disarming from the Master Keypad
To disarm all the Partitions to which you have access:
•[PIN] + [Off]. This will disarm all the partitions to which you have access even if they are already disarmed.
To disarm only some of the Partitions to which you have access:
•[PIN] + [#] + [#]. This puts you into Single Partition Mode.
•The first partition to which you have access is displayed: “Armed. Cafeteria.”
•If you wish to disarm this partition, enter [Off]. If not, go to the next step.
•[#] + [#] opens the next partition to which you have access.
•The next partition to which you have access is displayed: “Armed. Office.”
•If you wish to disarm this partition, enter [Off]. If not, go to the next step.
•After disarming any or all partitions to which you have access, you may exit Single Partition Mode by holding the [*] key for at
LED | Off | Flashing |
| On |
Armed | All partitions are disarmed. | One or more partitions are armed, or |
| All Partitions are armed, and no |
(red) |
| an alarm has occurred. |
| alarms have occurred. |
Status | Not ready to arm (if the Armed LED is | One or more zones are bypassed. |
| All partitions are ready to arm. |
(green) | On, all partitions are armed). |
|
|
|
Power | The Control Panel has lost all power; | Control Panel problems exist. |
| Normal Operation. |
(green) | no AC or battery. | See Error Displays. |
| The Control Panel is running on AC |
|
|
|
| power with no problems, |
Fire | There are no fire alarms. | A fire zone is in alarm. |
| A fire trouble condition exists. |
(red) |
|
|
|
|
DS7400Xi ( 4+) Reference Guide | Copyright © 2007 Bosch Security Systems, Inc. | P/N: |