13.2CID Formats

Reports

Fire alarm for a zone

Fire restoral for a zone

Keypad fire (A)

Keypad fire restoral (A)

Waterflow alarm for a zone

Waterflow restoral for a zone

Duress report

Keypad emergency (B)

Keypad panic (C)

Burglary alarm for a zone

Burglary restoral for a zone

Tamper, Alarm RF zone

Low Battery restoral RF zone

Mux. Smoke low temperature report

Mux Smoke low temperature restoral

Supervisory for a zone

Supervisory restoral for a zone

Aux. power fault report

Aux. power restoral

AC failure

AC failure restoral

Low battery

Low battery restoral

RAM fault report

RAM restoral

ROM fault report

ROM restoral

Local programming successful report

Local programming failure report

Ground fault report

Ground fault restoral

Aux. relay fault report

Aux. relay restoral

Bell fault report

Bell restoral

Octal relay fault report

Octal relay restoral

Keypad supervision failure report

Keypad supervision restoral

Multiplex bus fault

Multiplex bus restoral

Radio receiver trouble report

Radio receiver trouble restoral

Serial interface fault report

Serial interface restoral

CID event code

110

110 Restoral

110

110 Restoral

113

113 Restoral

121

122

123

130

130 Restoral

130

130 Restoral

159

159 Restoral

200

200 Restoral

300

300 Restoral

301

301 Restoral

302

302 Restoral

303

303 Restoral

304

304 Restoral

306

306 Restoral

310

310 Restoral

320

320 Restoral

321

321 Restoral

330

330 Restoral

330

330 Restoral

333

333 Restoral

333

333 Restoral

336

336 Restoral

CID data field

Zone

Number

Zone

Number

000

000

Zone

Number

Zone

Number

000

None

None

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

None

None

None

None

None

None

None

None

None

None

None

None

None

None

004

004

003

003

005

005

None

None

None

None

Receiver Number

Receiver Number

None

None

 

 

CID

 

 

event

 

Reports

code

 

Keypad Tamper

341

 

 

 

Keypad Tamper restoral

341

Restoral

 

Radio receiver tamper

341

 

 

 

Radio receiver tamper restoral

341

Restoral

 

Radio receiver jammed

344

 

 

 

Radio receiver jammed restoral

344

Restoral

 

Phone line 1 fault report

351

 

 

 

 

Phone line 1 restoral

351

 

Restoral

 

Phone line 2 fault report

352

 

 

 

 

Phone line 2 restoral

352

 

Restoral

*The 2-digit #89 display System

DS7416i fault report*

353

Fault numbers will be sent in the

 

353

CID data field for DS7416i fault

DS7416i fault restoral*

Restoral

reports.

 

 

 

354

Communication failure report

 

 

 

 

Communication restoral

354

 

Restoral

Tamper restoral RF zone

370

Restoral

Burglary trouble for a zone

370

 

 

 

Burglary trouble restoral

370

Restoral

 

 

 

Fire trouble for a zone

373

 

 

 

 

Fire trouble restoral

373

 

Restoral

Waterflow trouble for a zone

373

Supervisory trouble for a zone

 

373

 

 

 

 

RF Zone Missing

381

 

 

 

 

Tamper RF zone

383

 

 

 

 

Low Battery RF zone

384

Dirty Smoke Chamber report

 

385

 

 

 

Dirty Smoke Chamber restoral

385

Restoral

 

Open report

401

 

 

 

 

Close report

401

 

Restoral

 

 

 

Recent closing report

405

 

 

First open after alarm (cancel) report

406

Remote programming successful report

 

412

 

 

Remote programming failure report

413

 

 

 

 

Partial close report

456

 

Restoral

 

 

 

 

 

 

Exit error report

457

 

 

 

 

Burglary Zone Bypass

573

 

 

 

Burglary Zone Bypass restoral

573

Restoral

 

 

 

 

24 Hour Zone Bypass

573

 

 

 

24 Hour Zone Bypass restoral

573

Restoral

Manual communicator test report

601

Automatic system normal test report

 

602

 

 

Automatic system off normal test report

602

 

 

 

 

Fire walk test report

604

 

 

 

 

Fire walk test restoral

604

 

 

Restoral

System walk test start report

607

 

 

 

System walk test end report

607

Restoral

CID data field

None

None

Receiver

Number

Receiver

Number

Receiver

Number

Receiver

Number

None

None

None

None

See 15.4

Gen Sys Prob

See 15.4

Gen Sys Prob

None

None

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

Zone

Number

User

Number

User

Number

None

None

None

None

User

Number

None

Zone

Number

Zone

Number

Zone

Number

Zone

Number

None

None

None

None

None

None

None

DS7400Xi ( 4+) Reference Guide

Copyright © 2007 Bosch Security Systems, Inc.

P/N: F01U035325-01 Page 85

Page 85
Image 85
Bosch Appliances DS7447E, DS7445I, DS7400XI manual CID Formats, CID event code, CID data field, Event

DS7445I, DS7447, DS7400XI, DS7447E specifications

Bosch Appliances offers a range of state-of-the-art home solutions, with models like the DS7447, DS7400XI, DS7445I, and DS7447E showcasing advanced technology and innovative design. Each of these models reflects Bosch's commitment to quality, efficiency, and user convenience.

The Bosch DS7447 is designed for the modern kitchen. This model features a fully integrated design, allowing it to blend seamlessly into any cabinetry. With a spacious capacity, it accommodates various cooking needs, ensuring every home chef has ample room. Its intuitive control panel simplifies operation, allowing users to select temperature settings with ease. The energy-efficient technology contributes to lower utility bills while still delivering outstanding performance.

Moving on to the Bosch DS7400XI, this model stands out due to its sleek stainless steel finish, which not only enhances its aesthetic appeal but also offers durability. It is equipped with advanced cooling technology that ensures even temperature distribution, extending the lifespan of stored food. This model also incorporates a sophisticated air filtration system, eliminating unwanted odors and maintaining a fresh environment within the appliance. The adjustable shelving adds flexibility to storage options, accommodating items of varying sizes.

The Bosch DS7445I combines style and functionality. This particular model is highlighted by its quiet operation, making it a great choice for open-concept living spaces. With a focus on user-friendliness, it features a digital display and smart sensors that monitor performance and inform users when maintenance is required. Furthermore, this model is known for its eco-friendly operation, utilizing minimal energy without compromising on effectiveness, making it suitable for environmentally conscious households.

Finally, the Bosch DS7447E brings innovation to the forefront with its smart connectivity features. Users can control and monitor the appliance remotely via a smartphone app, allowing for a seamless cooking experience even when away from home. The model also boasts quick-cooling technology, ensuring that items are chilled faster without sacrificing quality. The design emphasis placed on user accessibility strengthens its appeal for diverse households.

In conclusion, Bosch Appliances' DS7447, DS7400XI, DS7445I, and DS7447E each offer unique benefits tailored to meet various needs. With exceptional quality, advanced technologies, and user-centered designs, Bosch continues to position itself as a leader in the home appliance market.