Whirlpool W10240580A, 99044505A Installation Requirements, Tools and Parts, Location Requirements

Page 4
INSTALLATION REQUIREMENTS

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Drill

1¹⁄₄" (3.0 cm) drill bit

¹⁄₈" (3.0 mm) drill bit for pilot holes

Pencil

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Flat-blade screwdriver

Phillips screwdriver

For vented installations, you also need:

Saber or keyhole saw

Vent clamps

Metal snips

Compass or 8" (20.3 cm) circle template

Parts supplied

Remove parts from package. Check that all parts are included.

Filter

4 - #10 x ⁵⁄₈" mounting screws

7" (17.8 cm) round transition plate

7" (17.8 cm) damper/vent connector

3¹⁄₄" x 10" (8.3 x 25.4 cm) damper/vent connector

Parts needed

For direct wire installation

UL listed or CSA approved ¹⁄₂" (12.5 mm) strain relief

Two 40-watt maximum incandescent light bulbs

Power supply cable (if needed, for direct wire installation)

For power supply cord installation

UL Listed Power Supply Cord Connection Kit marked for range hood use.

Two 40-watt maximum incandescent light bulbs

For vented installations you also need:

3¹⁄₄" x 10" (8.3 x 25.4 cm) or 7" (17.8 cm) round metal venting

7" (17.8 cm) round damper, if using 7" (17.8 cm) round vent system

For cabinets with recessed bottoms:

Two 2" (5.1 cm) wide filler strips. Length and thickness determined by recess dimensions.

Four flat head wood screws or machine screws with washers and nuts (to attach filler strips).

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the rear wall.

Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult the cooktop/range manufacturer installation instructions before making any cutouts.

Grounded electrical outlet is required. See “Electrical Requirements” section.

The hood is factory-set for vented installations. For non- vented (recirculating) installations, charcoal filter pad Part Number 4396846 is available from your dealer.

All openings in ceiling and wall where range hood will be installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.

Product Dimensions

1¹⁄₂"

12"

(3.8 cm)

 

 

 

1"

(30.5 cm)

 

 

9"

 

 

(2.5 cm)

(22.9 cm)

2"

 

 

 

 

 

 

(5.1 cm)

 

6"

 

 

 

(15.2 cm)

 

 

 

³⁄₄"

 

 

 

(1.9 cm)

 

 

 

 

 

 

1¹⁄₂"

 

 

 

(3.8 cm)

 

7 ¹⁄₂"

³⁄₈"

 

(9.5 mm)

 

(19.1

cm)

 

 

29 ⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model

35 ⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model17 ¹⁄₂" (44.5 cm)

4

Image 4
Contents 99044505A/W10240580A Installation Instructions and Use & Care Guide30 76.2 CM AND 36 91.4 CM RANGE HOOD HOTTE D’ASPIRATION DE 30 76,2 CM ET 36 91,4 CMRANGE HOOD SAFETY RANGE HOOD SAFETYINSTALLATION REQUIREMENTS INSTALLATION INSTRUCTIONSIMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONSINSTALLATION REQUIREMENTS For Mobile Home InstallationsProduct Dimensions For vented installations, you also needInstallation Clearances Cold Weather InstallationsVenting Requirements vented models onlyCalculating Vent System Length 7 17.8 cm Vent System3¹⁄₄ x 10 8.3 cm x 25.4 cm Vent System Example vent systemINSTALLATION INSTRUCTIONS Determine Wiring Hole Location2.To wire through top Electrical RequirementsTo wire through rear wall Roof VentingWall Venting Roof VentingFor vented installations Install Vent SystemIf using a vertical rectangular vent If using a horizontal rectangular ventInstall Range Hood For non-ventedinstallationsIf using a vertical round vent 4.For Direct Wire InstallationsComplete Installation Direct Wire InstallationInstall 40-wattmax type A-15appliance light bulbs Install Charcoal filterCleaning Non-Ventedrecirculating Installation FiltersCleaning Method For vented installationsASSISTANCE OR SERVICE If you need replacement partsIn the U.S.A In CanadaLIMITED WARRANTY ITEMS EXCLUDED FROM WARRANTYThis limited warranty does not cover callSÉCURITÉ DE LA HOTTE DE CUISINIÈRE DANGER AVERTISSEMENTIMPORTANTES INSTRUCTIONS DE SÉCURITÉ CONSERVEZ CES INSTRUCTIONSEXIGENCES DINSTALLATION Exigences demplacementInstallation dans une résidence mobile Dimensions du produitInstallations pour régions à climat froid Exigences concernant lévacuationUniquement pour modèles avec évacuation Dégagements de séparation à respecterLongueur maximale recommandée Spécifications électriquesSystème de décharge de 7 17,8 cm Système de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cmINSTRUCTIONS DINSTALLATION Préparation de lemplacementAVERTISSEMENT 2.Câblage à travers le fond du placardDécharge à travers le toit Décharge à travers le murCâblage à travers le mur arrière Découpage dune ouverture rectangulaire de 4 x 10½Installations avec décharge à lextérieur Installation du conduit dévacuationPréparation de la hotte Installation de la hotte Installations sans décharge à lextérieur4.Pour les installations à raccordement direct En cas dutilisation dun conduit rond verticalAchever linstallation Installation du filtre à charbonRaccordement électrique Raccordement par câblage directCommandes de la hotte de cuisinière Installations avec décharge à lextérieurRemplacement du filtre à charbon UTILISATION DE LA HOTTESi vous avez besoin de pièces de rechange ASSISTANCE OU SERVICEPour plus d’assistance GARANTIE DES GROS APPAREILS MÉNAGERS WHIRLPOOL CORPORATIONGARANTIE LIMITÉE ARTICLES EXCLUS DE LA GARANTIEW10240580A 20094/09 All rights reserved