If using a vertical round vent:
Attach round vent connector with 2 screws. Install a round damper (purchased separately).
3.Install the 4 - #10 x ⁵⁄₈" mounting screws in pilot holes. Leave about ¹⁄₄" (6.4 cm) space between screw heads and cabinet to slide range hood into place.
For non-vented installations
Check that the baffle plate has not been installed in the slot behind the grille. If is has, remove the baffle plate.
A
A. Baffle plate
Install Range Hood
1.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood. Set range hood aside on a covered surface.
A
A. Keyhole slot
2.Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.
A
A. Drill pilot hole
¹⁄₄"
(6.4 mm)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
4.For Direct Wire Installations:
■ Install a UL listed or CSA approved strain relief.
A
A. UL listed or CSA approved strain relief
■Pull about 12" (30 cm) of wire through wall or cabinet and into opening.
For Power Supply Installations:
■Follow instructions included with power supply cord kit marked for range hoods.
5.Using 2 people, lift range hood into final position, feeding electrical wire through wiring opening. Position the range hood so that the large end of the keyhole slots are over the screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots.
6.Check that damper, if used, rotates up and down freely.
7.For Vented Installations Only:
Connect ventwork to hood. Seal joints with clamps to make secure and airtight.
10