Whirlpool 99044505A, W10240580A Prepare Range Hood, For vented installations, Install Vent System

Page 9
For vented installations

To make a 7¹⁄₄" (18.4 cm) circle on the underside of the cabinet top:

1.Mark a centerline on the underside of the top of cabinet.

2.Mark a line 5" (12.7 cm) from the back wall on the underside of the top of cabinet.

3.Draw a circle using a compass or 7¹⁄₄" (18.4 cm) circle template.

4.Use saber or keyhole saw to cut a 7¹⁄₄" (18.4 cm) diameter opening.

7 ¹/₄" (18.4 cm) diam.

For vented installations

1.Insert the baffle plate into the slot behind the grille. The locator bumps should be at the top.

A

B

*5"

(12.7 cm)

*From wall, not cabinet frame

Cabinet cutouts

A. Locator bumps

B. Baffle plate

2.Remove either top or rear rectangular vent knockout. If using round vent, remove both top rectangular and semicircular knockouts.

3.Install vent connector:

If using a vertical rectangular vent:

Attach rectangular damper/vent connector to the top of the range hood using 2 screws.

Install Vent System

1.Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the selected venting method. See “Venting Requirements” section.

2.Use caulking to seal exterior wall or roof opening around the cap.

Prepare Range Hood

1.Remove terminal box cover. Depending on your installation, remove either back or top wiring knockout.

A

A. Terminal box cover

2.Remove the rectangular and round vent connectors from hood. Set the connectors and screws aside for use if connecting to a rectangular vent system.

If using a horizontal rectangular vent:

Attach rectangular damper/vent connector to the back of the range hood using 2 screws. Insert damper vent connection through the wall cutout and into the vent.

NOTE: If the wall cap is directly behind the vent connector, the dampers in the connector and wall cap must not interfere with each other. Remove the vent connector damper if they interfere.

A

A. Wall/cutout

9

Image 9
Contents Installation Instructions and Use & Care Guide 99044505A/W10240580A30 76.2 CM AND 36 91.4 CM RANGE HOOD HOTTE D’ASPIRATION DE 30 76,2 CM ET 36 91,4 CMRANGE HOOD SAFETY RANGE HOOD SAFETYINSTALLATION REQUIREMENTS INSTALLATION INSTRUCTIONSSAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONSFor Mobile Home Installations INSTALLATION REQUIREMENTSProduct Dimensions For vented installations, you also needCold Weather Installations Installation ClearancesVenting Requirements vented models only7 17.8 cm Vent System Calculating Vent System Length3¹⁄₄ x 10 8.3 cm x 25.4 cm Vent System Example vent systemDetermine Wiring Hole Location INSTALLATION INSTRUCTIONS2.To wire through top Electrical RequirementsRoof Venting To wire through rear wallWall Venting Roof VentingInstall Vent System For vented installationsIf using a vertical rectangular vent If using a horizontal rectangular ventFor non-ventedinstallations Install Range HoodIf using a vertical round vent 4.For Direct Wire InstallationsDirect Wire Installation Complete InstallationInstall 40-wattmax type A-15appliance light bulbs Install Charcoal filterNon-Ventedrecirculating Installation Filters CleaningCleaning Method For vented installationsIf you need replacement parts ASSISTANCE OR SERVICEIn the U.S.A In CanadaITEMS EXCLUDED FROM WARRANTY LIMITED WARRANTYThis limited warranty does not cover callDANGER AVERTISSEMENT SÉCURITÉ DE LA HOTTE DE CUISINIÈRECONSERVEZ CES INSTRUCTIONS IMPORTANTES INSTRUCTIONS DE SÉCURITÉExigences demplacement EXIGENCES DINSTALLATIONInstallation dans une résidence mobile Dimensions du produitExigences concernant lévacuation Installations pour régions à climat froidUniquement pour modèles avec évacuation Dégagements de séparation à respecterSpécifications électriques Longueur maximale recommandéeSystème de décharge de 7 17,8 cm Système de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cmPréparation de lemplacement INSTRUCTIONS DINSTALLATIONAVERTISSEMENT 2.Câblage à travers le fond du placardDécharge à travers le mur Décharge à travers le toitCâblage à travers le mur arrière Découpage dune ouverture rectangulaire de 4 x 10½Installation du conduit dévacuation Installations avec décharge à lextérieurPréparation de la hotte Installations sans décharge à lextérieur Installation de la hotte4.Pour les installations à raccordement direct En cas dutilisation dun conduit rond verticalInstallation du filtre à charbon Achever linstallationRaccordement électrique Raccordement par câblage directInstallations avec décharge à lextérieur Commandes de la hotte de cuisinièreRemplacement du filtre à charbon UTILISATION DE LA HOTTEASSISTANCE OU SERVICE Si vous avez besoin de pièces de rechangePour plus d’assistance WHIRLPOOL CORPORATION GARANTIE DES GROS APPAREILS MÉNAGERSGARANTIE LIMITÉE ARTICLES EXCLUS DE LA GARANTIE2009 W10240580A4/09 All rights reserved