Whirlpool 99044505A Venting Requirements, vented models only, Installation Clearances, Makeup Air

Page 5
Installation Clearances

Installation Clearances

30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width

18"(45.7 cm) min.

24" (61.0 cm)

suggested max. bottom of cabinet to cooking surface

13" (33.0 cm) cabinet depth

18" (45.7 cm) min. clearance upper cabinet to countertop

36" (91.4 cm) base cabinet height

Venting Requirements

(vented models only)

Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use a 4" (10.2 cm) laundry-type wall cap.

Use a 7" (17.8 cm) round metal vent or a 3¹⁄₄" x 10"

(8.3 x 25.4 cm) rectangular metal vent. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale.

Consult your HVAC professional for specific requirements in your area.

Venting Methods

Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10" (8.3 x 25.4 cm) with a maximum vent length of

35 ft (10.7 m) or 7" (17.8 cm) round vent with a maximum length of 50 ft (15.2 m) for vent system.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that gently reduces performance.

Roof Venting

Wall Venting

A

D

A

 

 

B

B

D

 

 

C

C

 

 

 

A. 7" (17.8 cm) round vent or a 3¹⁄₄" x 10" (8.3 x 25.4 cm) vent through roof

B. Round vent: use 7" (17.8 cm) round damper (purchased separately)

C. 18" (45.7 cm) - 24" (61.0 cm) above cooking surface

D. Roof cap

A. 7" (17.8 cm) round vent or a 3¹⁄₄" x 10" (8.3 x 25.4 cm) vent through the wall

B. 3¹⁄₄" x 10" (8.3 x 25.4 cm) through the wall

C. 18" (45.7 cm) - 24" (61.0 cm) above cooking surface

D. Wall cap

5

Image 5
Contents Installation Instructions and Use & Care Guide 99044505A/W10240580A30 76.2 CM AND 36 91.4 CM RANGE HOOD HOTTE D’ASPIRATION DE 30 76,2 CM ET 36 91,4 CMRANGE HOOD SAFETY RANGE HOOD SAFETYINSTALLATION REQUIREMENTS INSTALLATION INSTRUCTIONSSAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONSFor Mobile Home Installations INSTALLATION REQUIREMENTSProduct Dimensions For vented installations, you also needCold Weather Installations Installation ClearancesVenting Requirements vented models only7 17.8 cm Vent System Calculating Vent System Length3¹⁄₄ x 10 8.3 cm x 25.4 cm Vent System Example vent systemDetermine Wiring Hole Location INSTALLATION INSTRUCTIONS2.To wire through top Electrical RequirementsRoof Venting To wire through rear wallWall Venting Roof VentingInstall Vent System For vented installationsIf using a vertical rectangular vent If using a horizontal rectangular ventFor non-ventedinstallations Install Range HoodIf using a vertical round vent 4.For Direct Wire InstallationsDirect Wire Installation Complete InstallationInstall 40-wattmax type A-15appliance light bulbs Install Charcoal filterNon-Ventedrecirculating Installation Filters CleaningCleaning Method For vented installationsIf you need replacement parts ASSISTANCE OR SERVICEIn the U.S.A In CanadaITEMS EXCLUDED FROM WARRANTY LIMITED WARRANTYThis limited warranty does not cover callDANGER AVERTISSEMENT SÉCURITÉ DE LA HOTTE DE CUISINIÈRECONSERVEZ CES INSTRUCTIONS IMPORTANTES INSTRUCTIONS DE SÉCURITÉExigences demplacement EXIGENCES DINSTALLATIONInstallation dans une résidence mobile Dimensions du produitExigences concernant lévacuation Installations pour régions à climat froidUniquement pour modèles avec évacuation Dégagements de séparation à respecterSpécifications électriques Longueur maximale recommandéeSystème de décharge de 7 17,8 cm Système de décharge de 3¹⁄₄ x 10 8,3 cm x 25,4 cmPréparation de lemplacement INSTRUCTIONS DINSTALLATIONAVERTISSEMENT 2.Câblage à travers le fond du placardDécharge à travers le mur Décharge à travers le toitCâblage à travers le mur arrière Découpage dune ouverture rectangulaire de 4 x 10½Préparation de la hotte Installation du conduit dévacuationInstallations avec décharge à lextérieur Installations sans décharge à lextérieur Installation de la hotte4.Pour les installations à raccordement direct En cas dutilisation dun conduit rond verticalInstallation du filtre à charbon Achever linstallationRaccordement électrique Raccordement par câblage directInstallations avec décharge à lextérieur Commandes de la hotte de cuisinièreRemplacement du filtre à charbon UTILISATION DE LA HOTTEPour plus d’assistance ASSISTANCE OU SERVICESi vous avez besoin de pièces de rechange WHIRLPOOL CORPORATION GARANTIE DES GROS APPAREILS MÉNAGERSGARANTIE LIMITÉE ARTICLES EXCLUS DE LA GARANTIE2009 W10240580A4/09 All rights reserved