5. Leak Testing:
IMPORTANT: Leak testing of the appliance shall be conducted as follows:
•After final gas connection is made, turn on manual gas valve and test all connections in gas supply piping and appliance for gas leaks with a soapy water solution. During this test all appliance gas valves have to be closed.
•In order to avoid property damage or serious personal injury , never use a Iighted match. If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for leak.
CONVERSION TO LP/PROPANE GAS
Every oven is provided with a set of injectors for the various types of gas. Select the injectors to be replaced according to the "INJECTORS TABLE".
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.
SETTING THE PRESSURE REGULATOR
1.Unscrew the regulator cover;
2.Unscrew the A component, reverse and screw it according to the LP/PROPANE regulation.
1
2
A
LP/PROPANE | NATURAL GAS |
REGULATION | REGULATION |
Fig. 7.5
INJECTORS TABLE
| NOMINAL | REDUCED | LP/PROPANE | NATURAL GAS | |||
| POWER | POWER | 11” W.C.P. | 4” W.C.P. | |||
BURNERS | BTU/hr | BTU/hr | Ø injector | Ø injector | |||
[1/100 mm] | [1/100 mm] | [1/100 mm] | [1/100 mm] | ||||
|
|
| |||||
|
|
|
|
|
|
| |
Oven burner | 11000 | 1500 | 96 | 34 | 164 | adjustable | |
|
|
|
|
|
|
| |
Broil burner | 7000 | – | 78 | – | 130 | – | |
|
|
|
|
|
|
|
29