Hobart HFB12 ML-114909, HFB12 ML-114906 manual Voltage Test, Empty Recipe

Page 7

Press the 1 button to begin the lamp test. The door will lock and the lamps will each turn on briefly. After each lamp is turned on successfully, the display will report Lamp OK. If all lamps pass, the oven will automatically return to the normal operating mode.

If a lamp does not operate properly, the test will stop and the display will show the number of the lamp that failed.

Lamp 2

Lamp Error

-------->> Press Any Key <<--------

Press any key to continue the test. At the end of the test, the display will show “Lamp Check Finished.” If a lamp was reported as an error, re-run the test and verify visually that the lamp did or did not light.

If either of the two light sensors failed to operate during the test, you will see the following message at the end of the test:

Lamp Check Finished

No Bottom Sensor

If either a lamp or a sensor are reported as a problem, call your local Hobart Service Office.

Voltage Test

After performing the lamp test, the screen will return to Recipe 1. On a new oven, the screen will say Empty Recipe.

Recipe 1

0:00

EMPTY RECIPE

Press the green START button. The door will lock, the blower will start, and a few seconds later the cycle will end and the door will unlock. Now hold down the 1 button and push the 7 button at the same time. The display will report the system voltage, single- or three-phase, and the phasing if three-phase. (The phasing will show as “CCW” or “CW.” Either phasing is acceptable. This information is used for troubleshooting only.) The display will be similar to one of these:

208Volts

Single-Phase

Automatic

240Volts

Three-Phase

Phasing CCW

Automatic

The voltage reported on this screen must match the nominal system voltage supplied to the oven: either 208 Volts or 240 Volts. Call your local Hobart Service Office if it does not match.

– 7 –

Image 7
Contents Tion Table of Contents Unpacking InstallationLocation United States of America Installation Codes and StandardsAssembly Exhaust Duct InstallationFor Cord-Connected Ovens For Hard-Wired OvensFor a Single-Phase 240 Volt Oven Electrical ConnectionsElectrical Data START-UP TestingLamp Test Empty Recipe Voltage TestApproved Never Use PrecautionsOperation Utensils to USETo Create or Edit a Recipe Programming the HFB12 Flashbake OvenLamp Center and Outer Power Levels Fig To Save a Recipe or Exit Programming ModeRecipe Options and Limits Creating a Standard Cook Method Recipe Cook Time Lamp PowerStandard Recipe Display Full Power TmeCreating a TWO-STEP Cook Method Recipe Time Zone PowerOperating the HFB12 Oven Two-Step Recipe DisplayStarting a Recipe Stopping or Pausing a RecipeExtending the Cook Time Cook Cycle Counter High THROUGH-PUT Volume ConsistencyCooking Hints Cleaning Setting Food TypeBlower Cleaning Tools Approved Cleaning Materials and Procedures CleanersOven Door Lamp Shield Rail Removing and Installing the TOP Lamp ShieldFuses MaintenanceLamp Replacement Inspecting the OvenProblem Possible Causes TroubleshootingMessage Action High Power is not on