EH1721 SERIES ELECTRIC FRYERS
CHAPTER 4:
4.3.2 Filter Operation (cont.)
5.After all oil has drained from the frypot into the filter pan, pull the yellow handle to open the oil return lines and activate the filter pump.
Pull the yellow handle to open the oil return valve and activate the filter pump.
6.Oil will begin to pump from the filter pan into the frypot. Allow the oil to circulate for approximately 5 minutes to remove suspended particles. If the frypot sides and bottom have sediment deposits, lift the heating elements and clean the frypot with the cleaning brush included with the fryer.
Allow the oil to circulate for 5 minutes to ensure all sediment and suspended particles are removed.
7.After the oil is filtered, close the drain valve (push the red handle until it stops) and allow the fryer to refill.