Frymaster 35 Series manual

Page 11

1.8.5 Replacing Burner Ceramic Targets

DANGER

Drain the frypot or remove the handle from the drain valve before proceeding further.

1.Disconnect the fryer from the electrical power and gas supplies.

2.On FM35 fryers, remove sections of the square-drain as necessary to expose the burner.

3.Disconnect the wires from the gas valve terminal block and pilot coil, marking each wire to facilitate reconnection.

4.Disconnect the pipe union collar at the right side of the gas valve.

5.Remove the burner hanger screws and lower the front of the main burner. Pull it forward to clear the rear burner hanger, then lower the burner to the floor.

6.Raise the front of the fryer enough to slide the burner from under the fryer cabinet.

7.To replace a ceramic target only, remove the wire, straighten the target locking tab with a pair of needle nose pliers or a screwdriver, and slide the target up and off the bracket. Slide the replacement target onto the bracket and bend the locking tabs down.

To replace the entire target assembly, use a 1/2-inch box end wrench to remove the orifice that holds the target to the manifold assembly.

Step 2: On FM35 fryers, sections of the drain system must be removed to access the burner assembly.

Step 3: Mark and disconnect the wires from the gas valve.

Step 5: These screws on each side of the drain valve must be removed to lower the burner from the frypot.

To replace a ceramic target only, remove the wire, bend this tab outward, and slide the target up and off the bracket.

1-7

Image 11
Contents Gas Fryers Hour Service HotlineCanada Page Series GAS Fryers Table of Contents Thermostats Functional DescriptionPilot Ignition System Control OptionsInch Calibrating the Thermostat Control On Standard MJ35 Fryers Adjusting the Pilot Flame Non-CE Gas ValvesCE Gas Valves On G-Model Fryers Page Replacing the High-Limit Thermostat in G Series Fryers Page Page Ferrule on thermopile unscrews from bottom of pilot Replacing the Frypot Three screws, on each side of the fluecap, must be removed Unreliable flame Problems Related to the Gas and/or Electrical CurrentPilot Failures No pilot flameProblems Related to the Gas Valve Problems Related to the Electrical CircuitsMillivolt Operator Terminal Panel Improper Burner FunctioningFailure to Control at Setpoint Improper Temperature ControlFiltration Problems Filter Magic Simplified Wiring Diagram Basket Lift Malfunctions LeakageBell Crank Basket Lift Wiring Diagram Binding/Jamming ProblemsMotor Problems Electrical ProblemsProbe Resistance Chart Probe Resistance ChartComponent AccessoriesBasket Lift Arm, MJ35 Left use 823-06931 for FM35 units Cabinetry System Component WIR0146SP Filter BoxesOne-Piece Filter Pan Assembly Items 7, 8, 10, 11, Frypot FrypotsFM35 MJ35 MJ35VThis page Intentionally Left Blank Components Natural Gas G20/G25 for thermocouple only, use OIL Component Power Shower and OIL Return Handle Components THERMOSTATS, TIMER, and Related Components This page Intentionally Left Blank Service Hotline