FRYPOTS

 

 

Note port for

Note location of probe

Note location of probe

fittings one directly

fittings offset from one

Power Shower

above the other

another

 

FM35

MJ35

MJ35V

Frypot

Frypot

Frypot

Item

Part #

Component

 

 

Frypots without Insulation

 

823-1111SP

Frypot without Insulation, Stainless Steel, FM35

 

823-0981SP

Frypot without Insulation, Stainless Steel, MJ35

 

823-2365SP

Frypot without Insulation, Stainless Steel, MJ35V

 

823-1112

Frypot without Insulation, Cold Rolled Steel, FM35

 

823-0980SP

Frypot without Insulation, Cold Rolled Steel, MJ35

 

823-2364SP

Frypot without Insulation, Cold Rolled Steel, MJ35V

 

 

Frypot with Flue and Insulation Installed

 

806-4080SP

Frypot Assy, Stainless Steel, FM35

 

806-4093SP

Frypot Assy, Stainless Steel, FM35 (used in Canadian units only)

 

806-3942SP

Frypot Assy, Stainless Steel, MJ35

 

806-7709SP

Frypot Assy, Stainless Steel, MJ35V

 

806-4081SP

Frypot Assy, Cold Rolled Steel, FM35

 

806-4092SP

Frypot Assy, Cold Rolled Steel, FM35 (used in Canadian units only)

 

806-3943SP

Frypot Assy, Cold Rolled Steel, MJ35

 

806-7708SP

Frypot Assy, Cold Rolled Steel, MJ35V

 

 

Flue Assembly with Insulation

*

806-0094

MJ35 (used in Canadian units only)

*

806-0289SP

J2XLR (used in Canadian units only)

*

806-3490SP

MJ35 (has no Rear Deflector Box)

*

806-4082

FM35 (has Rear Deflector Box)

*

806-4094

FM35 (used in Canadian units only)

* Not Illustrated.

2-8

Image 31
Contents Gas Fryers Hour Service HotlineCanada Page Series GAS Fryers Table of Contents Thermostats Functional DescriptionPilot Ignition System Control OptionsInch CE Gas Valves Adjusting the Pilot Flame Non-CE Gas ValvesCalibrating the Thermostat Control On Standard MJ35 Fryers On G-Model Fryers Page Replacing the High-Limit Thermostat in G Series Fryers Page Page Ferrule on thermopile unscrews from bottom of pilot Replacing the Frypot Three screws, on each side of the fluecap, must be removed Unreliable flame Problems Related to the Gas and/or Electrical CurrentPilot Failures No pilot flameProblems Related to the Gas Valve Problems Related to the Electrical CircuitsMillivolt Operator Terminal Panel Improper Burner FunctioningFiltration Problems Improper Temperature ControlFailure to Control at Setpoint Filter Magic Simplified Wiring Diagram Basket Lift Malfunctions LeakageBell Crank Basket Lift Wiring Diagram Binding/Jamming ProblemsMotor Problems Electrical ProblemsProbe Resistance Chart Probe Resistance ChartComponent AccessoriesBasket Lift Arm, MJ35 Left use 823-06931 for FM35 units Cabinetry System Component WIR0146SP Filter BoxesOne-Piece Filter Pan Assembly Items 7, 8, 10, 11, Frypot FrypotsFM35 MJ35 MJ35VThis page Intentionally Left Blank Components Natural Gas G20/G25 for thermocouple only, use OIL Component Power Shower and OIL Return Handle Components THERMOSTATS, TIMER, and Related Components This page Intentionally Left Blank Service Hotline