Frymaster 35 Series manual Adjusting the Pilot Flame Non-CE Gas Valves

Page 7

1.6Adjusting the Pilot Flame

Non-CE Gas Valves

1.For Non-CE Gas Valves, remove the screw from the pilot adjustment screw hole on the gas valve.

2.Using a small, flat-tipped screwdriver, turn the pilot adjustment screw counterclockwise to in- crease the length of the flame or clockwise to decrease the length of the flame. Adjust flame to a length of 1 to 1½ inches (25 to 38mm).

3.Reinstall the pilot adjustment screw cap.

The pilot adjustment screw on the Non-CE Honeywell valve is under this screw.

CE Gas Valves

Using a small, flat-tipped screwdriver, turn the pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to decrease the length of the flame. Adjust flame to a length of 25 to 38mm.

The pilot adjustment on the CE valve is here.

1.7Calibrating the Thermostat Control

On Standard MJ35 Fryers

1.Fill the frypot to the lower OIL-LEVEL line with cooking oil. If solid shortening is used, it must be tightly packed into the frypot before starting calibration procedure.

2.Light the pilot. (Refer to Chapter 3 of the Installation and Operation Manual, P/N 819-5776 for detailed lighting instructions.)

3.Insert a good grade thermometer or pyrometer into the frypot, about one inch from the thermostat.

4.Set the thermostat to 325°F (162°C).

5.Let the burner cycle on and off three times.

1-3

Image 7
Contents Gas Fryers Hour Service HotlineCanada Page Series GAS Fryers Table of Contents Thermostats Functional DescriptionPilot Ignition System Control OptionsInch CE Gas Valves Adjusting the Pilot Flame Non-CE Gas ValvesCalibrating the Thermostat Control On Standard MJ35 Fryers On G-Model Fryers Page Replacing the High-Limit Thermostat in G Series Fryers Page Page Ferrule on thermopile unscrews from bottom of pilot Replacing the Frypot Three screws, on each side of the fluecap, must be removed Unreliable flame Problems Related to the Gas and/or Electrical CurrentPilot Failures No pilot flameProblems Related to the Gas Valve Problems Related to the Electrical CircuitsMillivolt Operator Terminal Panel Improper Burner FunctioningFiltration Problems Improper Temperature ControlFailure to Control at Setpoint Filter Magic Simplified Wiring Diagram Basket Lift Malfunctions LeakageBell Crank Basket Lift Wiring Diagram Binding/Jamming ProblemsMotor Problems Electrical ProblemsProbe Resistance Chart Probe Resistance ChartComponent AccessoriesBasket Lift Arm, MJ35 Left use 823-06931 for FM35 units Cabinetry System Component WIR0146SP Filter BoxesOne-Piece Filter Pan Assembly Items 7, 8, 10, 11, Frypot FrypotsFM35 MJ35 MJ35VThis page Intentionally Left Blank Components Natural Gas G20/G25 for thermocouple only, use OIL Component Power Shower and OIL Return Handle Components THERMOSTATS, TIMER, and Related Components This page Intentionally Left Blank Service Hotline