1.2Accessing Fryers for Servicing

DANGER

Moving a fryer filled with cooking oil may cause spilling or splattering of the hot

liquid. Follow the draining instructions in Chapter 4 of this manual before

attempting to relocate a fryer for servicing.

1.Drain shortening from fryer.

2.Shut off the gas supply to the unit. Unplug the power cord(s) if equipped. Disconnect the unit from the gas supply.

3.Remove any attached restraining devices.

4.Relocate the fryer for service accessibility.

5.After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and plug in the electrical cords.

6.Refill with shortening.

1.3Cleaning the Gas Valve Vent Tube

Refer to Semi-Annual Checks and Services in Chapter 5, Preventive Maintenance, of the Installation and Operation Manual (P/N 819-5776).

1.4Checking the Burner Manifold Gas Pressure

Refer to Semi-Annual Checks and Services in Chapter 5, Preventive Maintenance, of the Installation and Operation Manual (P/N 819-5776).

1.5Adjusting Burner Ceramic Target Spacing and Alignment

DANGER

Drain the frypot or remove the handle from the drain valve before proceeding further.

Proper spacing of the top edge of the burner ceramic targets is ¾ inch (13 mm) from the frypot side. To adjust target spacing, bend the brackets to which they are attached away or toward the frypot to the proper distance. (A length of board of the proper thickness is useful as a gauge to verify spacing and alignment.)

3/4-inch

There should be about 3/4-inch spacing between the top edge of the targets and the side of the frypot.

1-2

Image 6
Contents Hour Service Hotline Gas FryersCanada Page Series GAS Fryers Table of Contents Control Options Functional DescriptionPilot Ignition System ThermostatsInch Adjusting the Pilot Flame Non-CE Gas Valves CE Gas ValvesCalibrating the Thermostat Control On Standard MJ35 Fryers On G-Model Fryers Page Replacing the High-Limit Thermostat in G Series Fryers Page Page Ferrule on thermopile unscrews from bottom of pilot Replacing the Frypot Three screws, on each side of the fluecap, must be removed No pilot flame Problems Related to the Gas and/or Electrical CurrentPilot Failures Unreliable flameProblems Related to the Electrical Circuits Problems Related to the Gas ValveImproper Burner Functioning Millivolt Operator Terminal PanelImproper Temperature Control Filtration ProblemsFailure to Control at Setpoint Filter Magic Simplified Wiring Diagram Leakage Basket Lift MalfunctionsElectrical Problems Binding/Jamming ProblemsMotor Problems Bell Crank Basket Lift Wiring DiagramProbe Resistance Chart Probe Resistance ChartAccessories ComponentBasket Lift Arm, MJ35 Left use 823-06931 for FM35 units Cabinetry System Component Filter Boxes WIR0146SPOne-Piece Filter Pan Assembly Items 7, 8, 10, 11, MJ35V FrypotsFM35 MJ35 FrypotThis page Intentionally Left Blank Components Natural Gas G20/G25 for thermocouple only, use OIL Component Power Shower and OIL Return Handle Components THERMOSTATS, TIMER, and Related Components This page Intentionally Left Blank Service Hotline