Frymaster 35 Series manual Improper Temperature Control, Failure to Control at Setpoint

Page 19

Occasionally a burner may apparently be operating correctly, but nevertheless the fryer has a slow recovery rate (the length of time required for the fryer to increase the oil temperature from 250ºF to 300ºF (121ºC to 149ºC). The primary causes of this are low burner manifold pressure and/or misaligned or missing deflector targets. If both of these causes are ruled out, the probable cause is a gas valve regulator that is out of adjustment. Refer to the Check Burner Manifold Pressure procedure in the semi-annual checks and services section of Chapter 5 of the Installation and Operation Manual (P/N 819-5776).

1.9.6 Improper Temperature Control

Temperature control is a function of several interrelated components, each of which must operate correctly. The principle component is the operating thermostat. Other components that may affect temperature control are the high-limit thermostat and the gas valve. The high-limit thermostat is checked by comparing the resistance in its leads for a given temperature with the chart on Page 1-19. See Section 1.9.4 for the procedures for checking the gas valve.

Failure to Control at Setpoint

The problem will be with the thermostat itself. Possible causes are that the thermostat is out of calibration, the knob or flexible shaft is loose on the thermostat shaft, a thermostat wire is disconnected or broken, or the thermostat is defective. Refer to Section 1.7 for instructions on calibrating the thermostat. To check for thermostat failure: Determine the temperature of the oil in the frypot using a thermometer or pyrometer placed at the tip of the probe, then check the for a resistance through the leads that is approximately equal to that given in the Probe Resistance Chart on Page 1-19 for the corresponding temperature. If this checks OK, check for at least 5 megaohms of resistance through each of the leads to ground. If both checks are not OK, replace the thermostat.

1.9.7 Filtration Problems

The majority of filtration problems arise from operator error. A common error is placing the filter paper on the bottom of the filter pan rather than over the filter screen.

When the complaint is “the pump is running, but no oil is being filtered,” check the installation of the filter paper, including size. While you are checking the filter paper, verify that the O-rings on the bottom of the filter pan and on the male disconnect (at inside rear of filter cabinet) are present and in good condition. Missing or worn O-rings will allow the pump to suck air and decrease its ef- ficiency.

If the pump motor overheats, its thermal overload will trip and the motor will not start until it is reset. If the pump motor does not start, press the red reset switch located on the end of the motor nearest the operator. If the pump then starts, something caused the motor to overheat. It may be just that several frypots were being filtered one after the other and the pump got hot. Letting the pump cool down for at least a half-hour is all that is required in this case. More often, the pump overheated for one of the following reasons:

Shortening was solidified in the pan or filter lines.

The operator attempted to filter oil or shortening that was not heated. Cold oil and shortening are thicker and can cause the pump motor to overheat.

1-15

Image 19
Contents Gas Fryers Hour Service HotlineCanada Page Series GAS Fryers Table of Contents Thermostats Functional DescriptionPilot Ignition System Control OptionsInch CE Gas Valves Adjusting the Pilot Flame Non-CE Gas ValvesCalibrating the Thermostat Control On Standard MJ35 Fryers On G-Model Fryers Page Replacing the High-Limit Thermostat in G Series Fryers Page Page Ferrule on thermopile unscrews from bottom of pilot Replacing the Frypot Three screws, on each side of the fluecap, must be removed Unreliable flame Problems Related to the Gas and/or Electrical CurrentPilot Failures No pilot flameProblems Related to the Gas Valve Problems Related to the Electrical CircuitsMillivolt Operator Terminal Panel Improper Burner FunctioningFiltration Problems Improper Temperature ControlFailure to Control at Setpoint Filter Magic Simplified Wiring Diagram Basket Lift Malfunctions LeakageBell Crank Basket Lift Wiring Diagram Binding/Jamming ProblemsMotor Problems Electrical ProblemsProbe Resistance Chart Probe Resistance ChartComponent AccessoriesBasket Lift Arm, MJ35 Left use 823-06931 for FM35 units Cabinetry System Component WIR0146SP Filter BoxesOne-Piece Filter Pan Assembly Items 7, 8, 10, 11, Frypot FrypotsFM35 MJ35 MJ35VThis page Intentionally Left Blank Components Natural Gas G20/G25 for thermocouple only, use OIL Component Power Shower and OIL Return Handle Components THERMOSTATS, TIMER, and Related Components This page Intentionally Left Blank Service Hotline