Sanyo STB1010C1, STB0823H1 Dimensional Data, Wall Sleeve Dimension Dimension of Wall Opening

Page 11

3. DIMENSIONAL DATA

Models STB0810C1 STB1010C1 STB1020C1 STB1220C1

STB0811C1 STB1023C1 STB1123C1 STB0823H1

Unit Dimension

Topview

25-15/16"

3 " 15 - /4

21 -1/2"

Frontview

Sideview

Unit : inch

Wall Sleeve Dimension

Dimension of Wall Opening

15 -5/8"

26"

 

Wall opening of

26 -1/8"

26-1/8˝ x 15-3/4˝

is required

16 -7/8"

Minimum Wall

15 -3/4"

Sleeve Opening

 

Unit : inch

7

Image 11 Contents
Sanyo 26˝ Through the Wall AIR Conditioners & Heat Pump Please Read Before Starting Example HOW to USE this ManualTable of Contents STB0823H1 Operating RangeModels STB0810C1 STB1010C1 STB1020C1 STB1220C1 Models STB0811C1 STB1023C1 STB1123C1Unit Specifications SpecificationsCooling & Electric Heating Heat Pump Models STB0811C1 STB1023C1 STB1123C1 STB0823H1Compressor Major Component SpecificationsPOW-STBH Room Thermostat YTB-2U136 YTB-2U358 Other Component SpecificationsWall Sleeve Dimension Dimension of Wall Opening Dimensional DataModel STB0823H1 Refrigerant Flow DiagramCooling Capacity Performance Data10,200 BTU/h 700 BTU/h 11,500 BTU/h 000 BTU/h 500 BTU/h 11,300 BTU/h 980 810 650 490 300 070 22.8 Heating Capacity Heat pump Performance 100 Outdoor ambient temperature F DBCooling only models Electrical CharacteristicsElectrical Data Cooling & electric heating models Cooling Heat pump modelModels STB0810C1 STB1010C1 Electrical Wiring DiagramsModels STB1020C1 STB1220C1 Model STB0811C1 Models STB1023C1 STB1123C1 Model STB0823H1 Layout for Electric Parts POW-STBH For model STB0823H1 P.C.B. Assy Printed PatternCheck lead wires and connectors TroubleshootingCheck before and after troubleshooting Check power supplyCircuit breaker trips or fuse blows Air conditioner does not operateCheck transformer Power is not suppliedCheck Mode selector on the control panel Neither fan motor nor compressor motor runsElectric heater does not work Some part of air conditioner does not operateOnly fan does not run Cooling only models Cooling & electric heating models Check setting temperatureOnly compressor unit does not run Check compressor and electrical partsExcessive cooling or heating Operation does not switch from Heat to Cool or Cool to HeatAir conditioner operates, but abnormalities are observed Poor cooling or heatingShort If a sensor is defective. Only for heat pump modelRoom temp. thermistor RTH is defective OpenMeasurement of Insulation Resistance for Electrical Parts Power Cord and UnitChecking Electrical Components Measurement of Insulation ResistanceChecking Thermistor Checking Motor CapacitorChecking Fan Motor Winding Checking Compressor Motor WindingRemoving Electrical Component Box Disassembly ProcedureRemoving Front Grille Removing Wall SleeveRemoving Electric Heater Removing Evaporator Removing Blower WheelRemoving Propeller Fan Removing CondenserRemoving Fan Motor Cooling Room Temperature ControlFunction Heating Heat Pump Model Model STB0823H1 Heating Except during defrosting operationDefrosting Operation Heating Heat Pump Model Model STB0823H1 Defrosting FlowchartDefrosting Mode Timing Chart Heat Pump Model STB0823H1 AppendixFan Switch Sanyo Hvac Service Center
Related manuals
Manual 11 pages 32.75 Kb Manual 1 pages 50.23 Kb