10. FUNCTION
10-1. Room Temperature Control
Room temperature control is obtained by cycling the compressor ON and OFF.
Cooling Only Model
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1
■Cooling
●Thermo. ON : When the room temperature rises above T + 4°F (T°F is set temperature). Compressor ➞ ON
●Thermo. OFF : When the room temperature falls below set temperature T°F. Compressor ➞ OFF
|
|
| Room temp. |
|
|
| T+4 °F |
|
|
|
|
set temp. | T °F |
|
|
|
|
Compressor | ON | OFF | ON | OFF | |
|
|
|
| ||
Fan motor |
| Set speed |
|
|