7-3. Some part of air conditioner does not operate.
7-3-1. Only fan does not run.
•Check fan rotation.
Turn fan gently once or twice by hand.
•Measure resistance of fan motor winding.
OK
•Check fan motor capacitor and
(Only for heat pump model)
• Check PCB Ass'y . (Power pack)
Fan cannot be turned.
•Check fan casing foreign matter on inside.
Fan motor burnout or foreign matter in bearings.
Remove foreign matter or repair.
Repair or replace.
7-3-2. Electric heater does not work.
Both for (cooling & electric heating models) and (heat pump model)
•Measure resistance of electric heater winding.
•Check to see if the circuit of heater thermostat is opened or closed ?
•Check continuity for thermal fuses.
(Only for heat pump model)
• Check PCB Ass'y. (Power pack)
Blown
•Measure coil resistance of heater relay.
Replace them.
31