Sanyo STB1123C1, STB0823H1, STB0810C1, STB1020C1, STB1010C1, STB1220C1 Layout for Electric Parts

Page 30

 

To avoid electrical shock hazard, be sure to

 

disconnect power before checking, servicing

WARNING

and/or cleaning any electrical parts.

 

 

Model STB0823H1

LAYOUT FOR ELECTRIC PARTS

Varistor

Main control switch

Capacitor

(FM)Control switch temp. setting

Fan switch

Lid

 

 

 

 

 

Thermistor room temp.

 

Power cord

 

 

 

 

 

 

 

 

 

Power pack control PCB

 

 

 

 

 

 

 

 

 

 

Power transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacitor (CM)

 

BEFORE OPENING THE BOX

 

 

 

 

 

 

 

AFTER OPENING THE BOX

 

26

Image 30 Contents
Sanyo 26˝ Through the Wall AIR Conditioners & Heat Pump Please Read Before Starting HOW to USE this Manual ExampleTable of Contents Models STB0811C1 STB1023C1 STB1123C1 Operating RangeModels STB0810C1 STB1010C1 STB1020C1 STB1220C1 STB0823H1Specifications Unit SpecificationsModels STB0811C1 STB1023C1 STB1123C1 STB0823H1 Cooling & Electric Heating Heat PumpMajor Component Specifications CompressorPOW-STBH Other Component Specifications Room Thermostat YTB-2U136 YTB-2U358Dimensional Data Wall Sleeve Dimension Dimension of Wall OpeningRefrigerant Flow Diagram Model STB0823H1Performance Data Cooling Capacity10,200 BTU/h 700 BTU/h 11,500 BTU/h 000 BTU/h 500 BTU/h 11,300 BTU/h 980 810 650 490 300 070 22.8 100 Outdoor ambient temperature F DB Heating Capacity Heat pump PerformanceElectrical Characteristics Electrical DataCooling only models Cooling & electric heating models Heat pump model CoolingElectrical Wiring Diagrams Models STB0810C1 STB1010C1Models STB1020C1 STB1220C1 Model STB0811C1 Models STB1023C1 STB1123C1 Model STB0823H1 Layout for Electric Parts P.C.B. Assy Printed Pattern POW-STBH For model STB0823H1Check power supply TroubleshootingCheck before and after troubleshooting Check lead wires and connectorsAir conditioner does not operate Circuit breaker trips or fuse blowsNeither fan motor nor compressor motor runs Power is not suppliedCheck Mode selector on the control panel Check transformerSome part of air conditioner does not operate Only fan does not runElectric heater does not work Check compressor and electrical parts Check setting temperatureOnly compressor unit does not run Cooling only models Cooling & electric heating modelsPoor cooling or heating Operation does not switch from Heat to Cool or Cool to HeatAir conditioner operates, but abnormalities are observed Excessive cooling or heatingOpen If a sensor is defective. Only for heat pump modelRoom temp. thermistor RTH is defective ShortMeasurement of Insulation Resistance Power Cord and UnitChecking Electrical Components Measurement of Insulation Resistance for Electrical PartsChecking Compressor Motor Winding Checking Motor CapacitorChecking Fan Motor Winding Checking ThermistorRemoving Wall Sleeve Disassembly ProcedureRemoving Front Grille Removing Electrical Component BoxRemoving Electric Heater Removing Blower Wheel Removing EvaporatorRemoving Condenser Removing Propeller FanRemoving Fan Motor Room Temperature Control FunctionCooling Heating Heating Except during defrosting operation Heat Pump Model Model STB0823H1Heat Pump Model Model STB0823H1 Defrosting Flowchart Defrosting Mode Timing ChartDefrosting Operation Heating Appendix Heat Pump Model STB0823H1Fan Switch Sanyo Hvac Service Center
Related manuals
Manual 11 pages 32.75 Kb Manual 1 pages 50.23 Kb