Cooling & Electric Heating Model
Models STB0811C1 STB1023C1 STB1123C1
■Cooling
●Thermo. ON : When the room temperature rises above T + 4°F (T°F is set temperature). Compressor ➞ ON
●Thermo. OFF : When the room temperature falls below set temperature T°F. Compressor ➞ OFF
|
|
| Room temp. |
|
|
| T+4 °F |
|
|
|
|
set temp. | T °F |
|
|
|
|
Compressor | ON | OFF | ON | OFF | |
|
|
|
| ||
Fan motor |
| Set speed |
|
|
■Heating
●Heater ON : When the room temperature falls below T – 4°F (T°F is set temperature). Heater ➞ ON
●Heater OFF : When the room temperature rises above set temperature T°F.
Heater ➞ OFF
Room temp.
set temp. T °F
Heater
ON |
OFF
ON |
OFF
Fan motor
Set speed
43