Middleby Marshall Oven IV. Thermocouple Installation, Thermocouple Installation Locations

Page 11

SECTION 2

INSTALLATION

IV. THERMOCOUPLE

INSTALLATION

1. Install the thermocouple sensing bulb into the correct hole in rear of bake chamber as shown in Figure 2-11.

2. Thread thermocouple lead through grommet and into the machinery compartment.

Figure 2-11

Thermocouple Installation Locations

3. Remove the right-side ac- cess panel of the machinery compartment.

Thread the thermocouple lead through the side of the machin- ery compartment as shown in Figure 2-12, and into the elec- trical box (at the right-front of the machinery compartment).

Figure 2-12

Placing the Thermocouple Leads

2-11

Image 11
Contents UNLOADING/UNPACKING Section InstallationVentilation Hood Dimensions Recommendations only II. INSTALLATION, PREPARATION, and SupplyOther Ventilation Concerns III. Ventilation SystemRequirements RecommendationsInstallation KIT Dimensions and Data PS360L Tandem Dimensions and Data PS360WB Double Tandem Dimensions and Data PS360U Tri Tandem Dimensions and Data PS360WB-U Tri Tandem Dimensions and Data PS360U Quad Tandem Dimensions and Data PS360WB-U Quad Tandem Placing the Thermocouple Leads IV. Thermocouple InstallationThermocouple Installation Locations Thermocouple Lead Connections Exploded View Upper Oven Stand AssemblyJoining the Oven Bodies Oven Positioning and AlignmentCooling Fan Removal Bolts and Spacers Aligning the Ovens for AssemblyTrim Strip Positioning Checking Track Rail Alignment22a Support Brackets Lower Oven Transition Frame PlacementReplacing Transition Frame Installing the Transition Floor Panel25a Installing the Conveyor Frame and BeltOutside Master Links Conveyor Link OrientationInside Master Links Conveyor Motor and Drive Chain Assembly Transition AssemblyOven Rough-In GAS Supply Electrical SupplyDo not USE Conduit For Ground VI. Electrical Connection Typical Oven Data Plate Models PS360/PS360WB VII. GAS Supply for GAS Heated Ovens Flexible Hose Connector InstallationDuring Pressure Testing Note ONE Following For USE with Liquid LP GAS VIII. Preparation for Various GasesFor USE with Natural GAS GAS Type and Pressure Label Burner/Piping AssemblyIX. Changing Orifices Volumetric MethodOrifice Manifold Pressure Method XI. Variations of Rated Supply PressuresTo Check GAS Supply Pressure Special Notices