INSTALLATION

2.Slide the conveyor belt through the support rods underneath the frame, and thread it through the oven. Then, reach through the oven window and pull the free end of the belt through the oven so that it lies atop the conveyor frame.

Check that the links on the conveyor are oriented as shown in Figure 2-26.

3.Connect the inside master links. Check that the links are oriented as shown in Figure 2-27.

Direction

of travel

Figure 2-26

Conveyor Link Orientation

IncorrectCorrect

positionposition

Figure 2-27

Inside Master Links

4.Connect the outside master links. Note that the outside master links have right and left sides. The right-side master link has an open hook facing you, as shown in Figure 2-28.

Direction of travel

Figure 2-28

Outside Master Links

2-20

Image 20
Contents Section Installation UNLOADING/UNPACKINGII. INSTALLATION, PREPARATION, and Supply Ventilation Hood Dimensions Recommendations onlyIII. Ventilation System RequirementsRecommendations Other Ventilation ConcernsInstallation KIT Dimensions and Data PS360L Tandem Dimensions and Data PS360WB Double Tandem Dimensions and Data PS360U Tri Tandem Dimensions and Data PS360WB-U Tri Tandem Dimensions and Data PS360U Quad Tandem Dimensions and Data PS360WB-U Quad Tandem Placing the Thermocouple Leads IV. Thermocouple InstallationThermocouple Installation Locations Thermocouple Lead Connections Assembly Exploded View Upper Oven StandJoining the Oven Bodies Oven Positioning and AlignmentCooling Fan Removal Aligning the Ovens for Assembly Bolts and SpacersChecking Track Rail Alignment Trim Strip PositioningTransition Frame Placement 22a Support Brackets Lower OvenInstalling the Transition Floor Panel Replacing Transition FrameInstalling the Conveyor Frame and Belt 25aOutside Master Links Conveyor Link OrientationInside Master Links Transition Assembly Conveyor Motor and Drive Chain AssemblyOven Rough-In GAS Supply Electrical SupplyDo not USE Conduit For Ground VI. Electrical Connection Typical Oven Data Plate Models PS360/PS360WB VII. GAS Supply for GAS Heated Ovens Flexible Hose Connector InstallationDuring Pressure Testing Note ONE Following For USE with Liquid LP GAS VIII. Preparation for Various GasesFor USE with Natural GAS Burner/Piping Assembly GAS Type and Pressure LabelVolumetric Method IX. Changing OrificesOrifice Manifold Pressure Method XI. Variations of Rated Supply PressuresTo Check GAS Supply Pressure Special Notices