9.Test-fit the transition section of the conveyor

frame, as shown in Figure 2-21. The alignment pins on the bottom of the frame ensure correct spacing of the center ovens.

Figure 2-21

Transition

Frame Placement

10.Attach the two angled support brackets between the two center ovens, as shown in Figures 2-22a and 2-22b.

Note that a LOWER OVEN (PS360L, PS360WB-L) uses different support brackets for the front and rear, while an UPPER OVEN (PS360U, PS360WB-U) uses identical brackets on the front and rear.

Figure 2-22a

Support Brackets -

Lower Oven

Figure 2-22b

Support Brackets -

Upper Oven

SECTION 2

INSTALLATION

Conveyor frame shown removed for clarity

2-17

Image 17
Contents UNLOADING/UNPACKING Section InstallationVentilation Hood Dimensions Recommendations only II. INSTALLATION, PREPARATION, and SupplyRequirements III. Ventilation SystemRecommendations Other Ventilation ConcernsInstallation KIT Dimensions and Data PS360L Tandem Dimensions and Data PS360WB Double Tandem Dimensions and Data PS360U Tri Tandem Dimensions and Data PS360WB-U Tri Tandem Dimensions and Data PS360U Quad Tandem Dimensions and Data PS360WB-U Quad Tandem Placing the Thermocouple Leads IV. Thermocouple InstallationThermocouple Installation Locations Thermocouple Lead Connections Exploded View Upper Oven Stand AssemblyJoining the Oven Bodies Oven Positioning and AlignmentCooling Fan Removal Bolts and Spacers Aligning the Ovens for AssemblyTrim Strip Positioning Checking Track Rail Alignment22a Support Brackets Lower Oven Transition Frame PlacementReplacing Transition Frame Installing the Transition Floor Panel25a Installing the Conveyor Frame and BeltOutside Master Links Conveyor Link OrientationInside Master Links Conveyor Motor and Drive Chain Assembly Transition AssemblyOven Rough-In GAS Supply Electrical SupplyDo not USE Conduit For Ground VI. Electrical Connection Typical Oven Data Plate Models PS360/PS360WB VII. GAS Supply for GAS Heated Ovens Flexible Hose Connector InstallationDuring Pressure Testing Note ONE Following For USE with Liquid LP GAS VIII. Preparation for Various GasesFor USE with Natural GAS GAS Type and Pressure Label Burner/Piping AssemblyIX. Changing Orifices Volumetric MethodOrifice Manifold Pressure Method XI. Variations of Rated Supply PressuresTo Check GAS Supply Pressure Special Notices