Extron electronic USP 507 manual Installation and cabling

Page 18

Installation, cont’d

Installation and cabling

Step 1 — Mount the unit

Turn off or disconnect all equipment power sources and rack mount the USP 507. See page 2-3.

Step 2 — Connect inputs

Connect inputs from video sources to the applicable connectors marked “Inputs” (see page 2-4,b to g for connector types).

Step 3 — Connect outputs

Connect video output devices to the applicable connectors marked “Outputs” (see page 2-5,h to k for connector types).

Step 4 — Connect control devices

LAN Ethernet port — Connect to an Ethernet LAN or WAN via this RJ-45 connector l to control the processor from a remote location, using a PC’s Internet browser. See Appendix B for network cable termination method.

Ethernet connection indicator LEDs marked indicate the status of the Ethernet connection. The green LED lights when connected to an Ethernet LAN, and the amber LED flickers as the devices communicate.

Control device port — For serial RS-232 or RS-422 control, connect a host computer or control system via the upper 9-pin D-sub connector m. RS-232 protocol (default values):

• 9600 baud • 1 stop bit • no parity • 8 data bits • no flow control.

NSee chapter 4, “SIS Programmer’s Guide” for definitions of the SIS commands. See chapter 5, “USP 507 Software” to install and use the control software.

Step 5 — Connect auxiliary device

RS-232 port — Connect an auxiliary device, such as an Extron switcher, to the lower RS-232 port n, using a NULL RS-232 cable only.

Step 6 — Connect power

AC power connector — Plug in a standard IEC power cord from a 100 to 240 VAC, 50 - 60 Hz power source into this receptacle a.

2-6 USP 507 • Installation

Image 18
Contents Universal Signal Processor USPConsignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschFCC Class a Notice Table of Contents Table of Contents, cont’d Installing and Starting the Signal Processing USP 507 Table of Contents IiiIv USP 507 Table of Contents One About the USP IntroductionAbout this Manual USP 507 IntroductionDefinitions Features Introduction, cont’dUSP 507 Introduction Two Important safety instructions Installationstallation, cont’dUL/Safety Requirements USP 507 InstallationUL guidelines for rack mounted devices Tabletop placementMounting the USP Rack mountingInstallation, cont’d Rear Panel Features and ConnectionsPower and video input connections Output, user interface, and control connections Installation and cabling Powering Up Resetting the Unit with the Reset ButtonDefault display cycle USP 507 Reset Mode Summary Mode Activation Result Purpose/NotesThree Special function buttons These four buttons are Front Panel OperationFront Panel Overview Picture control buttons These six buttons areSwitching Inputs Special Function Button OperationButton Backlighting FrontPanelOperation,co t’d USP 507 Menu SystemOverview of menus USP 507 Front Panel Operation NextSave a user preset Using the menusUser presets Recall a user presetInput configuration Settings for each signal formatOutput configuration Press Next or Menu to return to the Output ConfigurationImage capture/recall To capture an imageTo recall an image Advanced configuration To remove an image from the displayAdjust knob to turn the Auto Memory on or off. See -6 for View comm settings Edit comm settingsExit menu Setting the Front Panel Locks Executive Modes Scan converter configurationEnabling or disabling Executive mode 1 from the front panel Setting Up the USP 507 to Work with a Matrix Switcher USP 507 connected to a matrix switcherConnection must be via IP not RS-232 USP 507 Input #3 select the matrixRS-232 cable only Extron USPFour SIS Programmer’s Guide RS-232/RS-422 LinkEthernet LAN\⤀ Port Host-to-Processor Instructions Connection timeoutsUsing verbose mode Processor-Initiated MessagesProcessor Error Responses Using the Command/Response Table for SIS CommandsSIS Programmer’s Guide, cont’d Symbol definitions = SecamSIS Programmer’s Guide, cont’d Input Switching and Configuration Command Response Table for SIS CommandsCommand Ascii command Response Additional description $HSRTApix XphasTpix XalinX1%CONT X1% ColrX1%TINT X1%BRITX1* Zoom X1& HsizX1&VSIZ X1HPANX7%VTPO X2#OPOLX2$OSYN X7VSTDESX7&HDET ESX1&HSIZESX1&VSIZ ESX7&VDETX3&VDLY Advanced ConfigurationsX2TEST Front panel lockout executive mode\⤀PIP X5TIMEPicture in Picture Resets Information requestImage capture/recall to USP 507 flash memory Using the Command/Response Table for IP SIS Commands Command/Response Table for IP SIS Commands EFF WX12#CVECV EAEECJ WX12%CD~CJ Ethernet data portEDF Programmer’sGuide, cont’d ELFFive Starting the program Installing the programUSP 507 Software USP 507 USP 507 SoftwareUsing the Program OrientationFile menu USP 507 Software, cont’dControl program menus Options menuTools menu Download Now USP 507 USP 507 Software Help menu Sppcp Help file’s main windowControl tab Control tab screenConfiguration tab I/O Configuration tab screenAdvanced Settings tab Advanced Features Within this sectionScan Converter tab Scan Converter tab screenImage Capture tab Status barSix Start the Web browser program Accessing the Web PagesHtml Operation USP 507 Html OperationSystem Status System StatusIP Settings fields Configuration PagesSystem Settings Html Operation, cont’dGateway IP Address field Dhcp radio buttonsIP Address field Subnet Mask fieldDate/Time Settings fields Date/Time Settings fieldsScaler Settings Scaler settingsRGB delay, test pattern, and Edid selections Passwords PasswordsFirmware Upgrade Download product namefirmware version.exe buttonFile Management Choose file window with a firmware file selectedOther file management activities Uploading filesAdding a directory Delete all files Click Delete AllControl Pages User ControlMemory/Input Presets PIP Setup/PIP PresetsImages Image is not yet displayedReference Information AAppendix aSpecifications Reference InformationUSP 507 Reference Information Sync Reference Information, cont’d MtbfIncluded parts Part Numbers and AccessoriesAccessories Optional I/O boardsAppendixBB Ethernet Link Default addressEthernet Connection Ping to determine Extron IP addressConnect as a Telnet client Ping to determine Web IP addressUSP 507 Ethernet Connection Telnet tips Connecting to the USP 507 Open command\⤀Ethernet Connection, cont’d Escape character and Esc keyLocal and remote devices Subnetting a PrimerGateways IP addresses and octetsUnmasked octets are compared indicated by ? in figure B-6 Subnet masks and octetsDetermining whether devices are on the same subnet Masked octets are not compared indicated by X in figure B-6USA, Canada, South America Japan Central America Europe, Africa, and the Middle East ChinaAsia Middle East

USP 507 specifications

Extron Electronics has long been a leader in the field of professional AV system design, and one of their standout products is the USP 507. The USP 507 is an advanced universal speaker processor that is engineered to elevate audio performance across a variety of applications. Designed for both commercial and residential environments, the USP 507 combines cutting-edge technology with user-friendly features to deliver superior sound quality and precise audio control.

One of the main features of the USP 507 is its comprehensive signal processing capabilities. The device supports a range of audio formats and delivers 48 kHz or 96 kHz sample rates, ensuring high fidelity in audio reproduction. It also includes a configurable 5-band equalizer per channel, allowing users to fine-tune audio output to accommodate different room acoustics and speaker types.

The USP 507 is equipped with Extron’s patented SpeedMatch technology to enhance speaker performance and optimize audio clarity. This innovative technology automatically analyzes the audio signals and adjusts various parameters to compensate for environmental conditions, ensuring consistent sound quality across all outputs.

In terms of connectivity, the USP 507 offers a wide array of input and output options. It includes both balanced and unbalanced audio inputs to facilitate seamless integration with other audio equipment. Furthermore, the device provides multiple output zones, enabling simultaneous audio distribution to different areas within a facility.

The USP 507 features intuitive software for simplified setup and operation. The Extron Toolbelt application allows users to configure, manage, and monitor the speaker processor through an easy-to-navigate interface. This software enhances user experience by providing real-time diagnostics and seamless integration with other Extron devices.

Durability and reliability are also hallmarks of the USP 507. Built with high-quality materials, it is designed to withstand the demands of professional use while ensuring long-lasting performance. Additionally, the device comes equipped with advanced thermal management features to prevent overheating during extended operations.

In summary, the Extron USP 507 is a versatile universal speaker processor that combines advanced signal processing technologies, a user-friendly interface, and robust construction. Its ability to deliver superior audio performance makes it an ideal choice for various applications, ranging from corporate environments to high-end residential setups. With its comprehensive features and reliable performance, the USP 507 stands out as an essential tool for audio professionals seeking to enhance their sound experience.