Extron electronic USP 507 manual Tools menu

Page 61

Tools menu

Click on this to open a drop-down box displaying

nine selectable options: Data View/Trace Window...

Executive Mode, Sync Scaler to Matrix Switcher...,

System Settings..., Reset, and Update Firmware....

Data View/Trace Window... — Select this to open a separate window in which the transmit and receive (Tx/Rx) data between the control software on the host PC and the USP 507 can be viewed in ASCII format (see figure at right). During data transmission and receipt, the data tracer window is constantly updated. To close the window, click Close or the X in the window’s top right corner.

Executive Mode — Select this to open a secondary drop-down box, allowing selection between Input Switch/Freeze only, On, or Off. Select as desired.

Sync Scaler to Matrix Switcher — Select this to open a secondary window. Within that window enter the IP address

of the matrix switcher to which the USP 507 is connected. If required enter the (matrix) password, then click Connect to

Matrix. Select the output number from the Matrix Output to USP 507 drop-down list and click Take. The Matrix Status section displays the matrix output that is being monitored and the tied input. The USP 507 Input #3 section displays the current status of the input being used.

NThe matrix switcher must be connected via a configured input on the USP 507. See pages 3-14and 3-15 for information.

The matrix and the USP 507 must be connected to an active network at all

times to allow the products to remain synchronized. If the connection is lost, the script needs to be restarted by either sending the SIS command or by power cycling the USP 507.

Click Refresh Status to update the status of the matrix switcher. Refreshing the status returns updated information about which scaler input is tied to a particular matrix output.

If the matrix IP address needs to be changed or which output of the matrix the USP 507 is connected to, click Remove Sync Scripts.

USP 507 • USP 507 Software

5-5

Image 61
Contents USP Universal Signal ProcessorSafety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschFCC Class a Notice Table of Contents Table of Contents, cont’d USP 507 Table of Contents Iii Installing and Starting the Signal ProcessingIv USP 507 Table of Contents One About this Manual IntroductionAbout the USP USP 507 IntroductionDefinitions Introduction, cont’d FeaturesUSP 507 Introduction Two UL/Safety Requirements Installationstallation, cont’dImportant safety instructions USP 507 InstallationMounting the USP Tabletop placementUL guidelines for rack mounted devices Rack mountingRear Panel Features and Connections Installation, cont’dPower and video input connections Output, user interface, and control connections Installation and cabling Resetting the Unit with the Reset Button Powering UpDefault display cycle Mode Activation Result Purpose/Notes USP 507 Reset Mode SummaryThree Front Panel Overview Front Panel OperationSpecial function buttons These four buttons are Picture control buttons These six buttons areSpecial Function Button Operation Switching InputsButton Backlighting USP 507 Menu System FrontPanelOperation,co t’dOverview of menus Next USP 507 Front Panel OperationUser presets Using the menusSave a user preset Recall a user presetSettings for each signal format Input configurationPress Next or Menu to return to the Output Configuration Output configurationTo capture an image Image capture/recallTo recall an image To remove an image from the display Advanced configurationAdjust knob to turn the Auto Memory on or off. See -6 for Edit comm settings View comm settingsExit menu Scan converter configuration Setting the Front Panel Locks Executive ModesEnabling or disabling Executive mode 1 from the front panel USP 507 connected to a matrix switcher Setting Up the USP 507 to Work with a Matrix SwitcherUSP 507 Input #3 select the matrix Connection must be via IP not RS-232Extron USP RS-232 cable onlyFour RS-232/RS-422 Link SIS Programmer’s GuideEthernet LAN\⤀ Port Using verbose mode Connection timeoutsHost-to-Processor Instructions Processor-Initiated MessagesUsing the Command/Response Table for SIS Commands Processor Error ResponsesSIS Programmer’s Guide, cont’d = Secam Symbol definitionsSIS Programmer’s Guide, cont’d Command Ascii command Response Additional description Command Response Table for SIS CommandsInput Switching and Configuration $HSRTTpix XphasApix XalinX1%TINT X1% ColrX1%CONT X1%BRITX1&VSIZ X1& HsizX1* Zoom X1HPANX2$OSYN X2#OPOLX7%VTPO X7VSTDESX1&VSIZ ESX1&HSIZESX7&HDET ESX7&VDETX2TEST Advanced ConfigurationsX3&VDLY Front panel lockout executive mode\⤀X5TIME PIPPicture in Picture Information request ResetsImage capture/recall to USP 507 flash memory Using the Command/Response Table for IP SIS Commands Command/Response Table for IP SIS Commands ECV WX12#CVEFF EAE~CJ WX12%CDECJ Ethernet data portGuide, cont’d Programmer’sEDF ELFFive USP 507 Software Installing the programStarting the program USP 507 USP 507 SoftwareOrientation Using the ProgramControl program menus USP 507 Software, cont’dFile menu Options menuTools menu Download Now USP 507 USP 507 Software Sppcp Help file’s main window Help menuControl tab screen Control tabI/O Configuration tab screen Configuration tabAdvanced Features Within this section Advanced Settings tabScan Converter tab screen Scan Converter tabStatus bar Image Capture tabSix Html Operation Accessing the Web PagesStart the Web browser program USP 507 Html OperationSystem Status System StatusSystem Settings Configuration PagesIP Settings fields Html Operation, cont’dIP Address field Dhcp radio buttonsGateway IP Address field Subnet Mask fieldDate/Time Settings fields Date/Time Settings fieldsScaler settings Scaler SettingsRGB delay, test pattern, and Edid selections Passwords PasswordsDownload product namefirmware version.exe button Firmware UpgradeChoose file window with a firmware file selected File ManagementAdding a directory Uploading filesOther file management activities Delete all files Click Delete AllUser Control Control PagesPIP Setup/PIP Presets Memory/Input PresetsImage is not yet displayed ImagesAAppendix a Reference InformationReference Information SpecificationsUSP 507 Reference Information Sync Mtbf Reference Information, cont’dAccessories Part Numbers and AccessoriesIncluded parts Optional I/O boardsAppendixBB Ethernet Connection Default addressEthernet Link Ping to determine Extron IP addressPing to determine Web IP address Connect as a Telnet clientUSP 507 Ethernet Connection Ethernet Connection, cont’d Connecting to the USP 507 Open command\⤀Telnet tips Escape character and Esc keyGateways Subnetting a PrimerLocal and remote devices IP addresses and octetsDetermining whether devices are on the same subnet Subnet masks and octetsUnmasked octets are compared indicated by ? in figure B-6 Masked octets are not compared indicated by X in figure B-6Europe, Africa, and the Middle East China USA, Canada, South America Japan Central AmericaAsia Middle East

USP 507 specifications

Extron Electronics has long been a leader in the field of professional AV system design, and one of their standout products is the USP 507. The USP 507 is an advanced universal speaker processor that is engineered to elevate audio performance across a variety of applications. Designed for both commercial and residential environments, the USP 507 combines cutting-edge technology with user-friendly features to deliver superior sound quality and precise audio control.

One of the main features of the USP 507 is its comprehensive signal processing capabilities. The device supports a range of audio formats and delivers 48 kHz or 96 kHz sample rates, ensuring high fidelity in audio reproduction. It also includes a configurable 5-band equalizer per channel, allowing users to fine-tune audio output to accommodate different room acoustics and speaker types.

The USP 507 is equipped with Extron’s patented SpeedMatch technology to enhance speaker performance and optimize audio clarity. This innovative technology automatically analyzes the audio signals and adjusts various parameters to compensate for environmental conditions, ensuring consistent sound quality across all outputs.

In terms of connectivity, the USP 507 offers a wide array of input and output options. It includes both balanced and unbalanced audio inputs to facilitate seamless integration with other audio equipment. Furthermore, the device provides multiple output zones, enabling simultaneous audio distribution to different areas within a facility.

The USP 507 features intuitive software for simplified setup and operation. The Extron Toolbelt application allows users to configure, manage, and monitor the speaker processor through an easy-to-navigate interface. This software enhances user experience by providing real-time diagnostics and seamless integration with other Extron devices.

Durability and reliability are also hallmarks of the USP 507. Built with high-quality materials, it is designed to withstand the demands of professional use while ensuring long-lasting performance. Additionally, the device comes equipped with advanced thermal management features to prevent overheating during extended operations.

In summary, the Extron USP 507 is a versatile universal speaker processor that combines advanced signal processing technologies, a user-friendly interface, and robust construction. Its ability to deliver superior audio performance makes it an ideal choice for various applications, ranging from corporate environments to high-end residential setups. With its comprehensive features and reliable performance, the USP 507 stands out as an essential tool for audio professionals seeking to enhance their sound experience.