SIS Programmer’s Guide, cont’d

Command

ASCII command

Response

Additional description

 

(host to processor\

(processor to host\

 

 

 

 

 

Picture in Picture

 

 

 

PIP on/off

 

 

 

PIP input select

E X!PIP}

PipX!]

Turn PIP on and display input

 

 

 

X!.

PIP off

E0PIP}

Pip0]

Turn PIP off.

View PIP status

EPIP}

X! ]

View PIP window selection.

NWhen PIP is enabled, all picture control commands apply to the image in the PIP window.

Swap PIP

Swap

%

Tke]

Swap content between main

 

 

 

and PIP window.

On-screen clock

 

 

 

Enable on-screen clock

E X5^TIME}

TimeX5^]

Display the time on the video

 

 

 

output.

View settings

ETIME}

X5^]

View setting.

On-screen clock horizontal position

Specific value

E K X1^HCTR}

HctrKX1^]

Increment up

EK +HCTR}

HctrKX1^]

Increment down

EK -HCTR}

HctrKX1^]

View settings

EK HCTR}

X1^]

Set horizontal position to X1^. Shift clock right.

Shift clock left.

Horizontal position is X1^.

On-screen clock vertical position

Specific value

E K X1^VCTR}

VctrKX1^]

Increment up

EK +VCTR}

VctrKX1^]

Increment down

EK -VCTR}

VctrKX1^]

View settings

EK VCTR}

X1^]

Set vertical centering to X1^. Shift clock down.

Shift clock up.

Vertical position value is X1^.

N X! = Input selection

1 – 7

X1^ = H and V position

zero location is 2048, and limits are ± the output resolution

X5^ = On-screen clock

0 = disabled (default), 1 = date and time, 2 = time only, 3 = date only.

4-14 USP 507 • SIS Programmer’s Guide

Image 50
Contents Universal Signal Processor USPConsignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschFCC Class a Notice Table of Contents Table of Contents, cont’d Installing and Starting the Signal Processing USP 507 Table of Contents IiiIv USP 507 Table of Contents One About the USP IntroductionAbout this Manual USP 507 IntroductionDefinitions Features Introduction, cont’dUSP 507 Introduction Two Important safety instructions Installationstallation, cont’dUL/Safety Requirements USP 507 InstallationUL guidelines for rack mounted devices Tabletop placementMounting the USP Rack mountingPower and video input connections Installation, cont’dRear Panel Features and Connections Output, user interface, and control connections Installation and cabling Default display cycle Powering UpResetting the Unit with the Reset Button USP 507 Reset Mode Summary Mode Activation Result Purpose/NotesThree Special function buttons These four buttons are Front Panel OperationFront Panel Overview Picture control buttons These six buttons areButton Backlighting Switching InputsSpecial Function Button Operation Overview of menus FrontPanelOperation,co t’dUSP 507 Menu System USP 507 Front Panel Operation NextSave a user preset Using the menusUser presets Recall a user presetInput configuration Settings for each signal formatOutput configuration Press Next or Menu to return to the Output ConfigurationTo recall an image Image capture/recallTo capture an image Advanced configuration To remove an image from the displayAdjust knob to turn the Auto Memory on or off. See -6 for Exit menu View comm settingsEdit comm settings Enabling or disabling Executive mode 1 from the front panel Setting the Front Panel Locks Executive ModesScan converter configuration Setting Up the USP 507 to Work with a Matrix Switcher USP 507 connected to a matrix switcherConnection must be via IP not RS-232 USP 507 Input #3 select the matrixRS-232 cable only Extron USPFour Ethernet LAN\⤀ Port SIS Programmer’s GuideRS-232/RS-422 Link Host-to-Processor Instructions Connection timeoutsUsing verbose mode Processor-Initiated MessagesSIS Programmer’s Guide, cont’d Processor Error ResponsesUsing the Command/Response Table for SIS Commands Symbol definitions = SecamSIS Programmer’s Guide, cont’d Input Switching and Configuration Command Response Table for SIS CommandsCommand Ascii command Response Additional description $HSRTApix XphasTpix XalinX1%CONT X1% ColrX1%TINT X1%BRITX1* Zoom X1& HsizX1&VSIZ X1HPANX7%VTPO X2#OPOLX2$OSYN X7VSTDESX7&HDET ESX1&HSIZESX1&VSIZ ESX7&VDETX3&VDLY Advanced ConfigurationsX2TEST Front panel lockout executive mode\⤀Picture in Picture PIPX5TIME Image capture/recall to USP 507 flash memory ResetsInformation request Using the Command/Response Table for IP SIS Commands Command/Response Table for IP SIS Commands EFF WX12#CVECV EAEECJ WX12%CD~CJ Ethernet data portEDF Programmer’sGuide, cont’d ELFFive Starting the program Installing the programUSP 507 Software USP 507 USP 507 SoftwareUsing the Program OrientationFile menu USP 507 Software, cont’dControl program menus Options menuTools menu Download Now USP 507 USP 507 Software Help menu Sppcp Help file’s main windowControl tab Control tab screenConfiguration tab I/O Configuration tab screenAdvanced Settings tab Advanced Features Within this sectionScan Converter tab Scan Converter tab screenImage Capture tab Status barSix Start the Web browser program Accessing the Web PagesHtml Operation USP 507 Html OperationSystem Status System StatusIP Settings fields Configuration PagesSystem Settings Html Operation, cont’dGateway IP Address field Dhcp radio buttonsIP Address field Subnet Mask fieldDate/Time Settings fields Date/Time Settings fieldsScaler Settings Scaler settingsRGB delay, test pattern, and Edid selections Passwords PasswordsFirmware Upgrade Download product namefirmware version.exe buttonFile Management Choose file window with a firmware file selectedOther file management activities Uploading filesAdding a directory Delete all files Click Delete AllControl Pages User ControlMemory/Input Presets PIP Setup/PIP PresetsImages Image is not yet displayedReference Information AAppendix aUSP 507 Reference Information SpecificationsReference Information Sync Reference Information, cont’d MtbfIncluded parts Part Numbers and AccessoriesAccessories Optional I/O boardsAppendixBB Ethernet Link Default addressEthernet Connection Ping to determine Extron IP addressUSP 507 Ethernet Connection Connect as a Telnet clientPing to determine Web IP address Telnet tips Connecting to the USP 507 Open command\⤀Ethernet Connection, cont’d Escape character and Esc keyLocal and remote devices Subnetting a PrimerGateways IP addresses and octetsUnmasked octets are compared indicated by ? in figure B-6 Subnet masks and octetsDetermining whether devices are on the same subnet Masked octets are not compared indicated by X in figure B-6Asia Middle East USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle East China

USP 507 specifications

Extron Electronics has long been a leader in the field of professional AV system design, and one of their standout products is the USP 507. The USP 507 is an advanced universal speaker processor that is engineered to elevate audio performance across a variety of applications. Designed for both commercial and residential environments, the USP 507 combines cutting-edge technology with user-friendly features to deliver superior sound quality and precise audio control.

One of the main features of the USP 507 is its comprehensive signal processing capabilities. The device supports a range of audio formats and delivers 48 kHz or 96 kHz sample rates, ensuring high fidelity in audio reproduction. It also includes a configurable 5-band equalizer per channel, allowing users to fine-tune audio output to accommodate different room acoustics and speaker types.

The USP 507 is equipped with Extron’s patented SpeedMatch technology to enhance speaker performance and optimize audio clarity. This innovative technology automatically analyzes the audio signals and adjusts various parameters to compensate for environmental conditions, ensuring consistent sound quality across all outputs.

In terms of connectivity, the USP 507 offers a wide array of input and output options. It includes both balanced and unbalanced audio inputs to facilitate seamless integration with other audio equipment. Furthermore, the device provides multiple output zones, enabling simultaneous audio distribution to different areas within a facility.

The USP 507 features intuitive software for simplified setup and operation. The Extron Toolbelt application allows users to configure, manage, and monitor the speaker processor through an easy-to-navigate interface. This software enhances user experience by providing real-time diagnostics and seamless integration with other Extron devices.

Durability and reliability are also hallmarks of the USP 507. Built with high-quality materials, it is designed to withstand the demands of professional use while ensuring long-lasting performance. Additionally, the device comes equipped with advanced thermal management features to prevent overheating during extended operations.

In summary, the Extron USP 507 is a versatile universal speaker processor that combines advanced signal processing technologies, a user-friendly interface, and robust construction. Its ability to deliver superior audio performance makes it an ideal choice for various applications, ranging from corporate environments to high-end residential setups. With its comprehensive features and reliable performance, the USP 507 stands out as an essential tool for audio professionals seeking to enhance their sound experience.